Comunicações
Info
Uncertainty in tacheometric measurement of convergences in tunnels
The variations, along time, of the distances between object points on tunnel cross-sections (convergences) may be used in real time continuous tunnel monitoring systems, as decision tools, to activate signals of alert or alarm. Electronic tacheometers, especially the motorized ones, are frequently used to measure convergences. To quantify the levels of alert and alarm one should take into account the convergence measurement uncertainty. The paper deals with modelling the uncertainty of the convergence as a function of the instrumental uncertainty parameters, using the general formula for the propagation of variances. The model is applied to a simulated tunnel, where the special case of motorized tacheometers with automatic target recognition (ATR) systems is analysed.
Ano: 2006
Número Páginas:
7.
Autor(es): Henriques, M. J.; Casaca, J. M.
Editor: FIG
Keywords: Incerteza; Taqueómetro; Monitorização; Túnel
Info
Validação de programa informático para calibração de um calorímetro diferencial de varrimento e incerteza associada à determinação da entalpia de fusão
Procurou-se com a presente comunicação, apresentar uma metodologia de validação de um programa informático, desenvolvido no NMPC do LNEC especificamente para a calibração de um calorimetro diferencial de varrimento (DSC) e para calcular a incerteza associada à determinação da entalpia de fusão. Assim, após uma breve introdução, a presente comunicação expõe a formulação essencial que serviu de suporte ao desenvolvimento do programa informático referido, descreve os elementos que constituem o procedimento de validação do mesmo, apresenta o processo de estimativa da incerteza de medição e os resultados da análise efectuada.
Ano: 2006
Número Páginas:
21.
Autor(es): Real, L. P.; Ribeiro, A.
Editor: LNEC
Keywords: Fusão; Entalpia; Calorimetria diferencial de varrimento; Incerteza de medição; Software; Calibração; Calorímetro
Info
Vibration based damage identification of masonry structures
In the process of preservation of ancient masonry structures, damage evaluation and monitoring procedures are particularly attractive, due to the modern context of minimum repair and observational methods, with iterative and step-by-step approaches. High-priority research issues related to damage assessment and monitoring are global non-contact inspection techniques, sensor technology, data management, diagnostics (decision making and simulation), dynamic (modal) analysis, self-diagnosing / self-healing materials, and prediction of early degradation. On these concerns, the present paper aims to assess damage in masonry structures at an early stage. Replicates of historical constructions were built in virgin state. Afterwards, progressive damage was applied and modal identification analysis was performed at each damage stage, aiming at finding adequate correspondence between dynamic behavior and internal crack growth. Accelerations and dynamic strains were recorded in many points of the replicates. Comparisons between different techniques based on vibrations measurements are made to evaluate different damage identification methods.
Ano: 2006
Número Páginas:
10p.
Autor(es): Ramos, L.F.; Lourenço, P.; Campos Costa, A.; De Roeck, G.
Editor: Macmillan
Keywords: Masonry constructions; Dynamic (modal) analysis
Info
20 anos de ensaios em modelo reduzido para obras marítimas da Região Autónoma dos Açores
N/A
Ano: 2005
Autor(es): Silva, L. G.
Info
A ambientação de equipamento de observação geodésica
Em Geodesia aplicada à monitorização de deslocamentos em grandes barragens de betão e alvenaria, onde é necessário atingir precisões submilimétricas, há que ter em conta as mais variadas fontes de erros sistemáticos, quer os de origem instrumental, quer os de origem ambiental. Entre estes últimos, devem ser considerados os erros originados pela mudança brusca da temperatura envolvente do equipamento convencional de medição (teodolitos, taqueómetros e níveis ópticos), que se verifica, por exemplo, quando o equipamento não se encontra armazenado à mesma temperatura a que ocorre a observação. Durante o intervalo de tempo em que o equipamento se adapta à temperatura ambiente, decorrem fenómenos de ajustamento mecânico e electrónico que perturbam as leituras efectuadas. Nestas condições, torna-se necessário realizar uma adaptação do equipamento à temperatura ambiente de observação que é designada por ambientação térmica. A comunicação apresenta o resultado de um estudo efectuado em ambiente termicamente controlado, que teve como objectivo quantificar o impacto da ambientação térmica num teodolito e num taqueómetro electrónicos e num nível óptico, utilizados pelo Núcleo de Geodesia Aplicada do LNEC na observação geodésica de barragens de betão.
Ano: 2005
Número Páginas:
10.
Autor(es): Henriques, M. J.; Ramalhais R.; Antunes, A. L.
Editor: Lidel
Keywords: Taqueómetro; Ambientação
Info
A finite fault modeling of the 1755 Lisbon earthquake sources
This work uses a non-stationary stochastic seismological model, based on random vibration theory, for calculating response spectra and synthesizing strong ground motion acceleration records for Portugal Mainland. The validation of the method and comparison with strong ground motion records for Portugal are entirely carried out in terms of 5% damped pseudo absolute response spectra for acceleration. The calibrated model is used to simulate ground motion acceleration for the 1755 Lisbon earthquake. Five potential source rupture models that have been recently proposed by several authors for the 1755 Lisbon earthquake are tested: two analytical models based on hydrodynamic studies; two models based on seismic surveys and on from a recent suggestion based on induced stress changes. For all models, peak ground acceleration maps are compared with iso-intensities map of the earthquake in order to test the ability of the source models for estimating the intensities of the earthquake. The peak ground motion is calculated for different unknown parameters like the rupture velocity, the slip distribution and the nucleation point. The fault parameters like dimension, dip and strike are the ones proposed by the authors of the different analysed source models
Ano: 2005
Número Páginas:
578-583pp.
Autor(es): Carvalho, A. M.; Campos Costa, A.; Oliveira, C.S.
Revista: 250th Anniversary of the I755 Lisbon Earthquake: proceedings
Editor: LNEC
Keywords: Non-stationary stochastic seismological model
Info
A importância do quadro de referência nos sistemas de observação geodésica de grandes barragens
Os sistemas de observação geodésica usados na monitorização de deslocamentos nas grandes barragens de betão e alvenaria são constituídos por redes de triangulação horizontais e redes de nivelamento geométrico independentes. Os sistemas devem ser cuidadosamente planeados e materializados no terreno, não só como resposta à necessidade de uma exactidão sub milimétrica, como também tendo em atenção o grande período de vida útil das obras. Este cuidado especial deve estender-se à escolha dos instrumentos de medição e dos procedimentos operativos, ao modelo matemático usado no ajustamento e no controlo da qualidade das medições e à definição dos quadros de referência horizontais e verticais. Os quadros de referência horizontais e verticais são constituídos por conjuntos de pontos afastados da zona de influência da barragem, adequadamente materializados e bem fundados, de preferência em afloramentos rochosos. A instabilidade dos pontos do quadro de referência, juntamente com a deficiente calibragem dos instrumentos de medição, a não correcção das condições atmosféricas, os procedimentos operativos inadequados, os erros aleatórios e grosseiros, etc., constituem as mais importantes fontes dos erros que afectam a qualidade dos resultados (deslocamentos). Esta comunicação aborda uma situação real, verificada numa grande barragem de betão portuguesa, onde as variações das grandezas observáveis (ângulos azimutais) da rede de triangulação apontavam para deslocamentos inesperados dos pontos objecto localizados na barragem. Os testes estatísticos usados no controlo da qualidade das medições denunciaram, no entanto, um comportamento anormal do quadro de referência da rede. A comunicação descreve o sistema de observação geodésico da referida barragem, as medições levadas a cabo ao longo do tempo, os testes estatísticos usados no controlo da qualidade das medições e apresenta como explicação para o comportamento inesperado da barragem, a instabilidade do quadro de referência da rede de triangulação.
Ano: 2005
Número Páginas:
9.
Autor(es): Henriques, M. J.; Casaca, J. M.
Editor: Lidel
Keywords: Geodesia aplicada; Barragem; Monitorização; Quadro de referência
Info
A numerical study of sand mining in a conceptual scenario test
N/A
Ano: 2005
Número Páginas:
325-326.
Autor(es): Ramos, M. C.; Silva, P. A.; Fortunato, A. B.; Oliveira, A.; Sancho, F. E.
Info
A numerical study of sand mining in a conceptual scenario test
N/A
Ano: 2005
Número Páginas:
469-477.
Autor(es): Ramos, M. C.; Silva, P. A.; Fortunato, A. B.; Oliveira, A.; Sancho, F. E.
Info
A simple and efficient methodology to assess long-term shor//eline evolution. Case study
N/A
Ano: 2005
Número Páginas:
pp. 239-250.
Autor(es): Oliveira, F. S. B. F.
|