Papers
Info
Barrier for buildings: analysis of mechanical resistance requirements
Barriers (guardrails and balustrades) prevents people from falling, for example, from balcony, open windows and stairs. Barriers also retain, stop or guide person in buildings. To increase the transparency of these components, traditional materials such as bricks, wood and metal are being replaced by glass or an organic material, which has mechanical behavior different from traditional materials. Regulation usually specify some action to take into account in the design of barriers, but do not define the required resistance. There are no international standards (ISO or EN) to assess the fitness for use of barriers, only national standards, with different testing loading conditions and mechanical resistance requirements. In this paper is presented a comparison of requirements and experimental testing conditions specified in standards from Portugal, Spain, France, UK, USA and Brazil. The goal of this research is to find some equivalence between standards, regarding the mechanical resistance behavior of different materials (brittle/ductile materials) and set a worst case scenario as the basis for the guardrails mechanical resistance profile. Some relations between the service limits state (plasticity) of metal guardrails and maximum deflection are proposed.
Year: 2016
Number Pages:
281-288pp.
Author(s): Pinto, A.; Reis, L.
: Procedia Structural Integrity 1
Editor: ELSEVIER
Keywords: Numerical techniques; Experimental techniques; Case study; Durability; Fatigue; GuardRails
Info
Nexus water energy for hotel sector efficiency
Five and four stars
Year: 2016
Number Pages:
10p.
Author(s): Pinto, A.; Afonso, A.; Santos, A.; Rodrigues, C.; Rodrigues, F.
: Energy Procedia
Editor: ELSEVIER
Keywords: Four and five stars; Hotels; Decrease; Energy; Hidric
Info
On-site assessment of the discharge coefficient of open windows
For assessing the discharge coefficient of an opening it is necessary to measure, as accurately as possible,the flow rate and the corresponding pressure difference that occurs when the fluid passes through it.When the openings are as big as windows applied in common building spaces the open section of thewindow is not negligible when compared with the cross-section of the room. In these conditions, theflow velocity in the room is not negligible and the obstructions (e.g., furniture) are prone to have a higherinfluence on measurements. In addition, the external windows are subject to the wind action, whichmay also impair the measurement. Even though these are not the ideal conditions, they are the commonconditions in which natural ventilation occurs. In this paper, on site measurements of the dischargecoefficient of open windows were carried out and the feasibility of these measurements was evaluated.Two methods were used (flow driven by a fan and flow driven by wind action) and compared. It is shownthat the discharge coefficient of a side-hung casement window with a roller shutter may range fromCd= 0.41 to Cd= 0.81 and that the discharge coefficient of a bottom hung casement window is Cd= 0.84.
Year: 2016
Number Pages:
463-476pp.
Author(s): Teixeira da Cruz, H.; Viegas, J.
: Energy and Buildings
Editor: ELSEVIER
Volume:
126 /2016.
Keywords: Windows flow; Flow rate; Discharge coefficient; Natural ventilation
Info
Saltwater experiments with air curtains for smoke control in the event of fire
Smoke flow inside buildings is a major cause of death in the event of fire. Presently, fire or smoke doors areused, together with smoke control systems, to avoid smoke flowing beyond the boundaries of the firecompartment. In this research, it is proposed the use of downward air curtains to stop smoke flow, whichwill not impair visibility in escape routes. The methodology followed in this research includes: (i) thedevelopment of an analytical model that relates the relevant characteristic quantities of a plane jet with thecharacteristics of the environment in which the fire develops, (ii) small scale experiments with saltwatermodelling to assess the convective parameters that control the smoke tightness of the curtain, (iii) CFDsimulations to assess the performance of a full scale air curtain near a fire source and (iv) fire experiments with afull-scale test specimen. In this paper both the analytical model and the saltwater experiments are presented.Test results confirm that vertical downward air curtains are able to avoid smoke flow through openings andshow a good agreement with the theoretical model for predicting the minimum exhaust rate from the firecompartment. It has been shown that the exhaust flow rate depends on the air curtain flow rate and on the fluidheat expansion due to fire. Test results also make it possible to assess the minimum nozzle velocity to avoidsmoke leakage.
Year: 2016
Number Pages:
243-248pp..
Author(s): Viegas, J.
: Journal of Building Engineering
Editor: ELSEVIER
Keywords: Saltwater modelling; Experiments; Plane jets; Smoke control; Fire safety
Info
A função da luz natural no edificado
No contexto do ano internacional da luz, o artigo descreve as principais funções da luz no edificado
Year: 2015
Number Pages:
44-45pp..
Author(s): Santos, A. J.
: Ingeniunm
Editor: Ingenium Edições, Lda.
Volume:
Nº 147.
Keywords: Iluminação natural; Iluminação
Info
Determinação do teor de CO2 e estimativa de taxas de ventilação em lares de idosos
Determinação do teor de CO2 e estimativa de taxas de ventilação em lares de idosos. Portugal é um dos países mais envelhecidos, sabendo-se que a população idosa apresenta elevada prevalência de doenças crónicas e problemas respiratórios. Diversos estudos indicam que as pessoas desta faixa etária estão, em média, 19 a 20 horas em ambientes fechados. A Qualidade do Ar Interior (QAI) desempenha um papel crucial na qualidade de vida e na saúde dos idosos.
Year: 2015
Number Pages:
71-75pp.
Author(s): Viegas, J.; Aelenei, D.; Nogueira, S .; Sobreira , C.
: Revista Edificios e Energia
Editor: Media Line, Lda.
Volume:
n.º 101.
Keywords: Conforto; Ventilação; Qualidade do ar interior
Info
CO2 Concentration in day care centres is related to wheezing in attending children
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, childrens respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.
Year: 2014
Number Pages:
9pp.
Author(s): Martins, P.; Viegas, J.; Papoila, A .; Aelenei, D.; Caires , I.; Martins , J.; Marques , J.; Cano, M.; Mendes, A.; Virella , D.; Pinto, R.; Pinto , P.; Maesano , I.; Neuparth, N.
: European J Pedriatr
Editor: Publicado online
Keywords: Ventilatin; Kindergarten; Indoor air quality; Environmental health; Children
Info
Eficiência energética e comportamento passivo dos edifícios
Apesar da extensa utilização no léxico técnico, o conceitode eficiência energética nos edifícios sendo fácil deapreender é difícil de quantificar e de utilizar na comparaçãoe classificação de edifícios. A eficiência energéticado edifício é o quociente entre o serviço prestado (confortotérmico, qualidade do ar, água quente sanitária) e oconsumo de energia associado. Resulta, que a eficiênciaenergética depende das características do edifício, dosseus equipamentos de climatização (e todos os outros),mas também dos ocupantes, das suas preferências deconforto e da forma como estes utilizam (ou não) os dispositivose controlos à sua disposição. Este aspeto dosocupantes é decisivo na avaliação da eficiência energéticados edifícios e nas soluções ótimas.Desde o RCCTE de 1990 que a avaliação do desempenhotérmico e energético dos edifícios é realizada comparandoo indicador necessidades térmicas nominais do edifícioface a um valor de referência, admitindo que existe
Year: 2014
Number Pages:
31-36pp.
Author(s): Pinto, A.
: Energuia
Editor: Engenho e Media, Lda.
Volume:
8.ª Edição - maio 2014.
Keywords: Conforto; Comportamento térmico; Reabilitação; Eficiência energética
Info
Environment and health in children day care centres (ENVIRH) - Study rationale and protocl
Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A childrens respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and childrens health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC. © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L. All rights reserved.
Year: 2014
Number Pages:
13p.
Author(s): Martins, J.; Martins, P.; Viegas, J.; Aelenei, D.; Cano, M.; Teixeira, J.; Paixao, P.; Papoila, A .; Pinto , P.; Pedro, C.; Pinto, J.; Maesano , I.; Neuparth, N.
: Revista portuguesa de pneumologia
Editor: Elsevier Doyma
Keywords: Environmental exposure; Children day care centers; Building ventilation; Airway inflamation
Info
Environmental an Ventilation Assessment in Child Day Care Centers in Porto: The Envirh Project
Children attending day care centers (CDCC) have been reported to be more prone to infectious diseases when compared with those cared for at home, and are exposed to conditions that may increase the risk of allergies and asthma. Several studies revealed that consequences of poor ventilation conditions include high levels of carbon dioxide (CO2) and many other indoor pollutants commonly detected in schools. Nine child day care centers were selected randomly to participate in this study. Fifty-two classrooms were assessed for chemical, biological, physical, and allergen parameters in spring and winter seasons in these nine CDCC located in Porto, Portugal. Outdoor measurements were also conducted for comparison. Our results indicated that (i) particulate matter (PM10) median levels were above the national reference levels, both by classroom type and by season; (ii) TVOC kindergarten peak values may raise some concern; (iii) CO2 was present at high median and maximum levels during spring and winter assessment in both nurseries and kindergartens classrooms; (iv) total bacteria concentrations were 57- and 52-fold higher in the nursery and kindergarten than outdoors, respectively, for the spring season; (v) winter and spring median predicted mean vote (PMV) indices were between neutral (0) and slightly cool (? 1) in the thermal sensation scale for comfort situations (?2 to 2) for both types of classrooms; (vi) there were significant differences for both PMV and predicted percentage of dissatisfied (PPD) indices by season; and (vii) CO2, total bacteria, and gram-negative bacteria were associated with low airflow rates. These data will help to evaluate the effectiveness of current building operation practices in child day care centers regarding indoor air quality and respiratory health.
Year: 2014
Number Pages:
931-943pp.
Author(s): Mendes, A.; Aelenei, D.; Papoila, A .; Martins, P.; Aguiar, L.; Pereira, C.; Neves, P.; Nogueira, S .; Cano, M.; Proença, C.; Viegas, J.; Silva, S.; Mendes, D.; Neuparth, N.; Teixeira, J.
: Journal of Toxicology and Environmental Health
Editor: Taylor & Francis Group
Volume:
77 Part A.
Keywords: Children day care center; Indoor air quality; Ventilation
|
Comunicação
Info
Climate hazards and disaster risk: a contribuition for urban planning and risk assessment in mainland Portugal
Portugal is affected by recurrent meteorological, hydrological and climate extreme events, that cancontribute to disasters causing losses of life and severe economic and social damages. Floods, droughts,extreme temperatures, wind-storms are natural hazards occurring in our country, can lead to disaster incommunities exposed to these weather and climate-related events and incremented in some urban areaspresenting a high level of vulnerability. Knowing, anticipating and managing such risks are critical tasks inurban planning.It is crucial to take into account not only the extreme events in a statistical sense, but also the level ofexposure and vulnerability of urban settlements that can transform even small scale events into disasters,contributing for increasing socio-economic and ecological impacts. Understanding and modelling disasterand climate risk is more and more essential. Appropriate spatial climate information is important to beconsidered at the several scales of territory management and planning. In this work not only the key conceptsare described but also two hazard mapping examples concerning heat waves and snow are presented formainland Portugal. These aspects are finally related with urban and regional planning strategies to reducevulnerability and strengthen adaptation.
Year: 2016
Number Pages:
115-122pp.
Author(s): Silva, A.; Santo, F.; Ventura, J.; Pinto, A.
Editor: ICUR2016
Keywords: Urban planning; Exposure; Vulnerability; Natural disasters; Climate risk
Info
Comparative study of different modeling parameters for predicting vibrations on timber-frame floors
Existing buildings reforms should include quality parameters and in timber-frame building systems thevibration transmission should be well studied to comply with the acoustic requirements. The inputparameters for the prediction of vibrational response of floors can influence the results in modelledbuilding systems. In building structures, the analysis of radiation due to beam vibrations may berepresented from the wave propagation relationships as a one-dimensional system, a two-dimensionalsystem or a three-dimensional solid. Recent research indicates that for point connection, a beam isusually modelled as a one-directional element. However, for lightweight structures such modelling typedoes not show good correlation with experimental results. This study focuses on the differences that canbe obtain in the vibrational response due to an impact source exerted on typical timber-frame floors. Italso presents some examples for some modelling options for plate/beam systems with and withoutceiling, considering different connection types.
Year: 2016
Number Pages:
10p.
Author(s): Nunes, M.; Patrício, J.
Editor: LNEC
Keywords: Finite element analyses; Vibrational response; Timber-frame floors
Info
Controlo de fumo em parques de estacionamento cobertos - complexo Sky center, Luanda
A regulamentação de segurança contra incêndios exige a compartimentação de zonas de fogo, em parques de estacionamento cobertos, em áreas não superiores a 6.400 m2 ou 3.200 m2, caso o piso em questão se encontre, respetivamente, acima ou abaixo do nível de referência [1]. No entanto, as técnicas de controlo de fumo atuais permitem a instalação de um sistema de ventilação e de controlo de fumo baseado na utilização de ventiladores de indução para promover o escoamento para a periferia do parque, onde é realizada a sua exaustão para o exterior através de ventiladores axiais e, eventualmente dispensando a compartimentação física entre pisos, caso se assegure que a velocidade de escoamento na rampa seja compatível com a velocidade do jato de teto gerado por um incêndio nas imediações da rampa. Nesta comunicação apresenta-se a implementação de um sistema de ventilação e de controlo de fumo de indução, no Complexo Sky Center, em Luanda, em alternativa ao sistema clássico de condutas, inicialmente previsto em projeto.
Year: 2016
Number Pages:
13p.
Author(s): Cordeiro, P.; Vaz, R.; Eimermann, M.; Viegas, J.
Editor: LNEC
Keywords: Ventilação de indução; Controlo de fumo; Parques de estacionamento cobertos; Segurança contra incêndios
Info
Controlo de fumo por meios passivos em túneis
O controlo de fumo constitui um dos meios de mitigação do risco de incêndio que écorrentemente utilizado para prolongar as condições ambientais compatíveis com a evacuaçãodos ocupantes e as condições ambientais favoráveis para a aproximação dos bombeiros aoincêndio e ao seu combate. Este estudo aponta para a possibilidade de ocorrer a contaminaçãoda camada fria para distâncias a partir da fonte de calor inferiores a 400 m, quando seconsidera a geometria de uma galeria de duas vias de tráfego.
Year: 2016
Number Pages:
10p.
Author(s): Viegas, J.
Editor: LNEC
Keywords: Ventilação natural; Controlo de fumo; Túneis
Info
Energy analysis using cooperation betwenn BIM tools (revit and green building studio) and energy plus
Nowadays the growing concern about clima)c changes and the high exigency of buildings
Year: 2016
Number Pages:
3p.
Author(s): Aljundi, K.; Pinto, A.; Rodrigues, F.
Editor: BIM
Keywords: Building information modeling; Test cells; Energy simulation; Energy eficiency; BIM
Info
Equipamentos sociais de Lisboa e Porto. Características dos edifícios, ventilação e QAI
Foram realizados recentemente os projetos de investigação ENVIRH e GERIA, que tiveram por principal objetivo analisar a influência da ventilação e da qualidade do ar interior na saúde respiratória dos seus utilizadores. De entre a informação recolhida numa amostra significativa de creches, infantários e lares de idosos, são relevantes os dados sobre as características construtivas dos edifícios (em especial da sua envolvente, que condiciona a ventilação), as condições ambientais no seu interior (temperatura, humidade e teor de dióxido de carbono) e, nalguns casos, as taxas de ventilação observadas em períodos noturno e matinal (só em lares de idosos). Nesta comunicação são analisadas as condições de qualidade do ar interior e associadas às características construtivas dos edifícios, por um lado, e às condições de ventilação, nos casos onde foi possível medir diretamente essas taxas.Os dados recolhidos são também relevantes para se avaliar a contribuição dos procedimentos de abertura e fecho de portas e janelas para a qualidade do ambiente interior, como forma de reação adaptativa dos utilizadores às insuficiências inerentes aos modelos construtivos que caracterizam estes edifícios.
Year: 2016
Number Pages:
12p.
Author(s): Viegas, J.; Aelenei, D.; Nogueira, S .
Editor: LNEC
Keywords: Características construtivas; Lares de Idosos; Creches
Info
Estimativa da redução a sons de impacto: determinação da regidez de materiais resilientes
Este trabalho compara três formas de obtenção de frequência de ressonância, para fins deobtenção da rigidez dinâmica, que é o principal parâmetro para a estimativa de desempenhode sistemas de piso flutuante quanto à redução a sons de impacto. Sinais impulsivos foramutilizados através da excitação da placa de carregamento, com dois diferentes sistemas deaquisição de dados, enquanto o sinal sinusoidal foi utilizado através da vibração vertical daplaca de base. Também foi objetivo deste trabalho avaliar a rigidez estática dos materiais,de modo a obter uma comparação entre os valores de rigidez dinâmica e estática emmateriais resilientes poliméricos. Foram encontradas diferentes relações entre rigidezdinâmica e rigidez estática para os materiais expandidos e para os materiais fibrosos.
Year: 2016
Number Pages:
8p.
Author(s): Zuchetto, L.; Nunes, M.; Patrício, J.; Azevedo, F.S.
Editor: LNEC
Keywords: Ruído de impacto; Piso flutuante; Rigidez estática; Rigidez dinâmica
Info
Estudo de sensibilidade do desempenho de sistemas de ventilação de edifícios de habitação multifamiliar
Os sistemas de ventilação assumem uma grande importância no consumo de energia de climatização ena definição das condições higrotérmicas e da qualidade do ar interior dos edifícios. Sãoabsolutamente necessários para garantir níveis adequados de renovação do ar interior.Em Portugal, nos edifícios multifamiliares, recorre-se essencialmente a sistemas de ventilação natural,de exaustão mecânica ou mistos. No entanto, dificilmente se consegue aquilatar convenientementequal a correspondência entre o sistema de ventilação instalado e a taxa de ventilação atingida com omesmo.Neste artigo, através de simulação recorrendo ao software CONTAM e com base em dadosexperimentais da permeabilidade ao ar dos dispositivos de ventilação, realiza-se uma análise desensibilidade variando alguns dos parâmetros mais significativos nos sistemas de ventilação, taiscomo: perda de carga das grelhas de admissão, permeabilidade ao ar da caixilharia e caudais deextração na cozinha. A simulação anual dos fluxos de ar recorre a condições ambientaisrepresentativas do clima continental português (quatro cidades) e a subdivisão para as estações deaquecimento e arrefecimento, envolve também a produção de poluentes internos (CO2 e vapor deágua). Com a simulação, obteve-se, nomeadamente, para um apartamento tipo, as taxas de ventilação,os fluxos de ar de admissão e exaustão, os teores dos poluentes, pontualmente ou em termos médios.As conclusões mais significativas a retirar das simulações são: a baixa permeabilidade ao ar daenvolvente leva a reduções nas renovações horárias próximas do limite mínimo estabelecidoregulamentarmente; a ventilação mecânica contínua na cozinha, a existência de uma grelha deadmissão na cozinha, com abertura aquando dos caudais máximos, e o fecho das portas doscompartimentos de serviços reduz significativamente os teores de poluentes.
Year: 2016
Number Pages:
9p.
Author(s): Pinto, M.; Viegas, J.; Freitas, V.
Editor: REHABEND
Keywords: Humidade relativa; Renovações horárias; Simulação; Sistemas de ventilação; Habitações
Info
Full-Size of air curtains for smoke control in case of fire: final results
This paper analyses the air curtains capability to be used to prevent the smoke flow from the firecompartments. Full size experiments have been developed and several relevant conditions toassess smoke-tightness have been tested. During the tests the air curtain
Year: 2016
Number Pages:
11p.
Author(s): Viegas, J.; Teixeira da Cruz, H.
Editor: LNEC
Keywords: Vertical air curtains; Full size experiments; Plane jets; Smoke control
Info
Método LNEC para avaliação e classificação da qualidade acústica de edifícios habitacionais: ferramenta de estimação de custos médios de transição entre classes acústicas
The acoustic comfort in dwellings is essential to a peaceful and regenerative sleep. The achievement of this comfort is primarily obtained by reducing noise and increasing sound insulation of separating elements. To classify this comfort is necessary to conduct a comprehensive analysis of the habitation. This global analysis assesses the internal and external factors of the habitation, evaluating the acoustics of the environment (Vicinity), of the building (Building) and of the dwelling place (Lodging).Recently in Portugal was developed the
Year: 2016
Number Pages:
9p.
Author(s): Ferreira, A.; Patrício, J.; da Silva, J.
Editor: SPA
Keywords: LNEC; Previsão do conforto acústico; Classificação; Reabilitação; Acústica habitacional
|
Books
Info
Weathering of Polymers and Plastic Materials
This book presents the state of the art on the weathering of polymers and plastic materials in outdoor applications, comprising natural weathering, accelerated climatic weathering, laboratory artificial accelerated weathering, and lifetime prediction methodology. It summarizes the most suitable methods of instrumental analysis to access and quantify (when possible) degradation caused by weathering, while also covering the degradation and stabilization of polymers based on environmental and artificially induced factors. Innovative polymer additives and some developments in polymeric materials designed for outdoor applications are also included, emphasizing a few selected cases. the book intends to be an important reference source for those involved in the study of the durability of polymers and plastics, production of plastics for exterior applications, chemists responsible for quality control of plastic products, and researchers and students across plastics engineering, polymer science, polymer chemistry and environmental science.
Year: 2023
Number Pages:
XXIV, 136.
Author(s): Real, L. P.
: Weathering of Polymers and Plastic Materials
Editor: SPRINGER NATURE
Keywords: Lifetime prediction; Correlation; Durability; Polymer degradation; Polymer stabilization; Plastics; Artificial weathering; Climatic weathering
Info
Recycled Materials for Construction Applications - Plastic Products and Composites.
In this work, a general approach to the recyclability of plastics and composites used in construction, with the purpose of their reuse, is made.The various recycling technologies applicable to the plastic materials, most used in construction, and their various stages are described, detailing for the main polymers, and indicating the difficulties inherent in these processes. In this context, several Illustrative cases of success and examples of recent technological innovation are presented.It also addresses the issue of quality control, certification, and standardization adopted in Europe for recycled plastics.Some market data are presented, namely the production capacity, data for bio-based plastics and polymers, the quantities of recycled plastic and, for each type of polymer, statistics data on recycling and market barriers of recycled materials, also referring to the variables that most influence recycling costs and the price of recycled materials.The conclusions drawn from this work are of several types. In a succinct way, they demonstrate that recycling is a fundamental resource to minimize waste and reduce environmental pollution, constituting a strategic approach to the management of waste from plastic construction products at the end of its useful life.The main challenges and future perspectives that arise from the most recent developments in this area are made.Finally, the most relevant strategic recommendations are presented in order to continue and concretize the resolution of the problem of recycling plastics and seek to achieve the objectives of the circular economy, which involves the development of the specialized market for recycling and recycled plastics and, consequently, promote the purchase and sale operations of economic agents and interested parties (sellers, buyers, consumers, associations, recyclers, manufacturers of production machinery, etc.) in order to also increase the recycling and recyclability of plastic waste.
Year: 2022
Number Pages:
1-162.
Author(s): Real, L. P.
: Recycled Materials for Construction Applications - Plastic Products and Composites.
Editor: Springer
Keywords: Environmental impact; Recycling; Circular economy; Construction; Sustainability; Composites; Plastics
Info
Método LNEC para avaliação e classificação da qualidade acústica de edifícios habitacionais
Esta publicação apresenta uma metodologia para avaliar a qualidade acústica de edifícios habitacionais, ou partes deles (fogos), visando a sua qualificação em termos das características da componente acústica interior, nos espaços com utilização sensível, contribuindo, consequentemente, para a sustentabilidade ambiental e para o reforço dos padrões de qualidade de vida do cidadão. A metodologia proposta assenta num processo de avaliação segundo três linhas estratégicas fundamentais, às quais corresponde um determinado nível físico, respetivamente: uma relacionada com a integração da unidade edificada no seu ambiente próximo (ou seja, tendo em conta um contexto de planeamento), designada na presente publicação por Vizinhança; outra relacionada com a disposição interior dos diversos espaços funcionais e com a sua inter-relação cruzada, assim como com os diferentes usos que podem estar associados às diversas frações autónomas existentes (ex. fogos versus espaços comerciais), para além das caraterísticas acústicas dos espaços comuns, a qual é intitulada Edifício; e uma outra assente na eficácia acústica das soluções de compartimentação adotadas e no nível máximo admissível do ruído de equipamentos de uso coletivo, designada por Habitação. Por último, apresentam-se, a título de exemplo, algumas casos práticos que possibilitam demonstrar a potencialidade, as nuances, e o interesse de que se pode revestir o uso da metodologia em causa para classificação, e eventual etiquetagem, da qualidade acústica das unidades habitacionais, potenciando assim a qualidade correspondente e introduzindo um novo parâmetro de valoração de mercado.
Year: 2013
Number Pages:
77pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Conforto acústico; Avaliação; Controle de qualidade; Edifício de habitação; Acústica de edifício
Info
IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia
A IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia (MEFTE 2012) contempla diversas áreas temáticas onde métodos experimentais, analíticos e numéricos contribuem para o progresso nestas áreas científicas. Esta conferência é uma organização conjunta entre o Laboratório Nacional de Engenharia Civil (LNEC), a Universidade Nova de Lisboa (UNL), o Instituto Superior de Engenharia de Lisboa (ISEL), o Instituto Superior Técnico (IST), a Faculdade de Engenharia da Universidade do Porto (FEUP) e a Universidade de Coimbra (UC), sob os auspícios da Associação Portuguesa de Mecânica Teórica, Aplicada e Computacional (APMTAC). A APMTAC promove bienalmente esta conferência nacional temática, como um dos seus objectivos estratégicos e estatutários, no âmbito da mecânica dos fluidos, termodinâmica e energia. Na sequência do sucesso das conferências anteriores (2006 FCT-UNL, 2008 U. Aveiro, 2009 Instituto Politécnico de Bragança), a IV Conferência Nacional é realizada nas instalações do Laboratório Nacional de Engenharia Civil, nos dias 28 e 29 de Maio de 2012. Foram inicialmente submetidos 111 resumos de investigadores portugueses e estrangeiros, dos quais resultaram 80 comunicações que foram submetidas a avaliação. A Comissão Organizadora manifesta o seu apreço e agradece a todos os que contribuiram para a realização deste evento, em especial, aos membros das Comissões Científica e Executiva pelo seu esforço e dedicação, assim como a todos os autores e participantes. Agradecemos ainda aos oradores convidados para as sessões plenárias pelo seu contributo em tornar esta conferência um lugar de partilha de conhecimentos do estado da arte da mecânica de fluidos, termodinâmica e energia. Finalmente agradecemos aos nossos patrocinadores o seu apoio à realização desta conferência.
Year: 2012
Number Pages:
192pp.
Author(s): entidade LNEC
Editor: LNEC
Keywords: Congresso; Energia; Termodinâmica; Mecânica dos fluidos; Pt
Info
Road Tunnels: Operational strategies for emergency ventilation
Le présent document est un rapport préparé par le groupe de travail n° 6 « Ventilation et maîtrise des incendies » du comité technique C3.3 'Exploitation des tunnels routiers' de lAssociation mondiale de la Route (AIPCR). Ce rapport fournit des informations sur lexploitation des systèmes de ventilation des tunnels dans les cas durgence, principalement ceux causés par un incendie. En exploitation normale, la ventilation est nécessaire pour assurer la propreté de lair ambiant et préserver la visibilité dans le tunnel, en évitant laccumulation de gaz polluants et de particules. En cas dincendie, lexploitation de la ventilation doit être modifiée pour passer de son mode normal à un mode qui optimise les possibilités dévacuation des usagers du tunnel et dintervention sûre des services durgence. La stratégie à adopter dépend de la géométrie spécifique du tunnel, de la densité du trafic et de son mode de circulation uni ou bidirectionnel. Après une discussion des travaux antérieurs de lAIPCR et quelques remarques sur la directive européenne de 2004 et les recommandations nationales concernant la ventilation des tunnels, le rapport présente des informations sur les types de système de ventilation communément utilisés, tels que les systèmes longitudinal, transversal et semi-transversal. Les objectifs visés dans lidéal pour la maîtrise des fumées dans ces différents types de tunnel sont ensuite traités, et le mode de commande préféré est présenté. Ceci peut inclure, par exemple, le contrôle de la vitesse du courant dair longitudinal, une fonction qui peut ne pas être disponible dans tous les cas, mais qui devrait normalement être prévue dans un ouvrage nouveau. Les principes de la commande de la ventilation sont alors décrits dans leurs grandes lignes, et quelques remarques sur la maintenance et les essais de vérification suivent.
Year: 2011
Number Pages:
99p.
Author(s): Allemann, M.; Brandt, R.; Carlotti, P.; Viegas, J.
Editor: PIARC
Volume:
2011R02.
Keywords: Controlo de fumo; Ventilação; Túneis
Info
Sistemas de combate a incêndios em edifícios - De acordo com a nova regulamentação
Com o advento da nova regulamentação de segurança contra incêndios em edifícios, e tendo em conta a importância da mesma na segurança das pessoas e bens, pretende-se com este documento colocar à disposição dos projectistas, alunos de engenharia e de todos aqueles que se relacionem de alguma forma com a temática dos sistemas de combate a incêndios com água em edifícios, uma súmula das partes mais relevantes do regulamento, destinadas a este fi m, bem como a apresentação de metodologias de cálculo, adequadas, que facilitem a compreensão e aplicação destas, no sentido da obtenção de projectos que conduzam à produção de sistemas com níveis de desempenho funcional satisfatório.
Year: 2010
Number Pages:
74pp.
Author(s): Pedroso, V.
Editor: LNEC
Volume:
NS 117 Não Seriados.
Keywords: Protecção dos edifícios contra o fogo; Segurança contra incêndios
Info
A acústica nos edifícios. Pavimentos e revestimentos de pavimentos, isolamento a sons de percussão
As exigências relativas às condições acústicas dos edifícios encontram-se definidas no Regulamento dos Requisitos Acústicos dos Edifícios, aprovado pelo Decreto-Lei nº 129/2002 de 11 de Maio, com as alterações introduzidas pelo Decreto-Lei n.º 96/2008 de 9 de Junho. A necessidade de conhecimento das características de isolamento a sons de percussão, de diferentes soluções, na elaboração dos projectos de condicionamento acústico, fundamenta o objectivo desta publicação e é consubstanciado pela compilação de resultados de diferentes soluções obtidos em laboratório. No sentido de contextualizar a informação disponibilizada, referem-se os conceitos gerais, os parâmetros característicos e a terminologia utilizada, assim como as variáveis que condicionam o desempenho dos elementos de separação horizontal à transmissão de sons de percussão. É ainda apresentado um exemplo de estimativa das condições de isolamento a sons de percussão, usando o método simplificado constante da norma EN 12354-2:2000 Building Acoustics Estimation of acoustic performance of buildings from the performance of elements Part 2: Impact sound insulation between rooms.
Year: 2009
Number Pages:
133pp.
Author(s): Domingues, M.
Editor: LNEC
Keywords: Revestimento de pavimento; Pavimento de edifício; Isolamento acústico; Acústica de edifício
Info
Projecto de condicionamento acústico de edifícios
A Acústica apresenta um carácter diagonal no domínio do conhecimento científico, o que pode determinar dificuldades na abordagem de áreas específicas, como seja o domínio do condicionamento acústico de edifícios. Há também a considerar o facto de serem muito reduzidas as potências postas em jogo na audição humana, apesar de este sentido ser muito importante no diálogo do Homem com o Ambiente. Afigurou-se oportuno, face ao quadro esquissado, congregar, de modo ordenado, elementos entendidos como necessários para o desenvolvimento de estudos de engenharia no domínio do condicionamento acústico de edifícios. Não está em causa um pretenso tratado nem um vade-mécum de Acústica aplicada, mas um instrumento com interesse para quem pretenda exercer actividade de Engenharia Acústica, no projecto de condicionamento acústico de edifícios.
Year: 2009
Number Pages:
76pp.
Author(s): Silva, P. M.
Editor: LNEC
Keywords: Nível sonoro; Conforto acústico; Acústica de edifícios
|
|
Tese de Doutoramento
Info
Utilização de ventilação de impulso em parques de estacionamento cobertos
A aplicação da ventilação de impulso em parques de estacionamento cobertos tem conhecido uma grande expansão em Portugal no último decénio. Este tipo de ventilação baseia-se na utilização de um conjunto de ventiladores axiais, suspensos no tecto do parque de estacionamento, que gera um escoamento adequado para promover o varrimento entre a admissão de ar novo e a exaustão, normalmente realizada por ventiladores axiais periféricos, de forma a assegurar o escoamento para o exterior dos poluentes emitidos pelos veículos. Na condição de incêndio este sistema de ventilação é utilizado para limitar o escoamento do fumo no interior do parque de estacionamento coberto e também para promover o seu escoamento para o exterior. Neste documento é feita uma síntese crítica do conhecimento neste domínio utilizando o levantamento do estado do conhecimento nas matérias relevantes para estabelecer recomendações de concepção e de dimensionamento de tais sistemas. Este documento também identifica as necessidades de investigação neste domínio, detalha o conteúdo dos projectos de investigação que devem ser realizados, estabelece as bases da sua coordenação através de um programa de investigação de forma a ser possível criar sinergias e identifica as oportunidades de formação pós-graduada, apoiadas nesse programa de investigação.
Year: 2009
Author(s): Viegas, J.
Info
Aplicação da avaliação de ciclo de vida à análise energética e ambiental de edifícios
O impacto energético e ambiental dos edifícios é cada vez mais importante nas sociedades contemporâneas, pelo consumo de energia e de recursos durante a fase de utilização dos edifícios, mas também pelas fases de construção e demolição. Encontra-se comprovado que os edifícios são responsáveis por cerca de 46% do consumo de energia primária no concelho de Lisboa, mas não se encontra apreciado o impacte da fase de construção e demolição. No âmbito desta tese aplicou-se a metodologia de análise do ciclo de vida a edifícios, desde a fase de construção até à demolição, com o objectivo de avaliar os impactes ambientais directamente relacionados com o edifício, em particular avaliar as possíveis interacções entre a fase de construção e a fase de utilização. Para efectuar a análise do ciclo de vida foram inicialmente definidos os aspectos de conforto ambiental interior a satisfazer. Foram avaliados os impactes ambientais associados ao fabrico e à utilização de alguns materiais de construção e de instalações de edifícios de forma a possibilitar a ACV. Tendo em conta o impacte dos envidraçados nas necessidades energéticas na fase de utilização dos edifícios, foi efectuada a avaliação de diferentes soluções envidraçadas de forma a estabelecer áreas de vidro optimizadas que minimizem as necessidades energéticas de aquecimento, arrefecimento e iluminação. Foi avaliada experimentalmente a permeabilidade ao ar de edifícios Portugueses e foi avaliado o impacte da permeabilidade nas infiltrações de ar e nas necessidades de climatização para diferentes tipos de sistemas de ventilação, sendo apresentada uma proposta de limites a adoptar para os edifícios Portugueses. Por fim a metodologia de ACV do edifício foi aplicada a casos de estudo sendo evidenciado que o impacte ambiental dos edifícios vai para além do consumo de energia na fase de utilização, pois a fase de construção de edifícios novos e de fim-de-vida pode corresponder a sensivelmente 30% do impacte ambiental do edifício. Se for considerado apenas a construção, fase de fim-de-vida e a energia para climatização, o impacte ambiental da construção é de sensivelmente 90% para o caso de Lisboa. Nos casos de estudo foi evidenciado que existe um ponto de optimização do nível de isolamento térmico dos elementos opacos a partir do qual as poupanças de energia associadas ao incremente da espessura do isolante térmico não compensam a carga ambiental nele incorporada. Por outro lado para reduzir o impacte ambiental dos edifícios é evidenciado que a concepção de edifícios que prevejam a reutilização dos elementos de construção mais pesados tem um peso que é cerca do dobro do associado à optimização do isolamento térmico do edifício.
Year: 2008
Author(s): Pinto, A.
Keywords: Qualidade do ambiente interior; Declaração ambiental; Ciclo de vida; Eficiência energética; Edifícios; Sustentabilidade
|
Dissertação de Mestrado
Info
Projecto de desenvolvimento tecnológico de condutas de evacuação de produtos da combustão de turbinas a gás utilizadas para propulsão naval
Nos sistemas de evacuação dos produtos da combustão de turbinas a gás, utilizadas na propulsão naval de alguns navios de combate, tem-se verificado a ocorrência de nucleação e propagação de fissuras através das paredes de pressão do sistema, tendo as principais fissuras propagando-se a partir dos pés dos cordões de soldadura. A conduta do sistema em estudo é constituída num aço inoxidável austenítico, AISI 316L (N), designado pela norma EN 10088-1 por 1.4404, com uma espessura de aproximadamente 3,7 mm. Em estudos anteriores foi medida a temperatura exterior da parede de pressão da conduta, tendo-se registado 350 ºC na zona junto ao anel de suporte inferior. No presente trabalho, e com o intuito de se proceder a uma substituição localizada do material constituinte da conduta, foram realizados estudos metalográficos comparativos entre o aço inoxidável austenítico 1.4404 e o aço inoxidável austenítico 1.4376, tendo-se também efectuado a determinação da composição química dos mesmos. Definiu-se a geometria dos provetes de fadiga e de fluência (e tracção), tendo neste último sido determinado a carga máxima de ensaio e a sua verificação pelo método de elementos finitos. O trabalho foi concluído com a modelação numérica do escoamento do fluido, num programa de diferenças finitas comercial, para a determinação do campo de pressões e temperaturas actuantes na conduta.
Year: 2008
Author(s): Cruz, H.
Keywords: Modelação cfd; Aço inoxidável 1.4376; Aço inoxidável 1.4404; Turbina a gás; Conduta de evacuação dos produtos da combustão
|
Relatório Científico
Info
EMPREENDIMENTO SEIXAL BAÍA 1.ª FASE, LOTES 8, 10, 11 e 12 Certificado LNEC da qualidade do processo de instalação da caixilharia exterior
N/A
Year: 2009
Number Pages:
20pp.
Author(s): Pina dos Santos, C.
Info
Avaliação da eficácia das medidas de minimização de impactes ambientais implementadas em Portugal
O presente relatório foi elaborado para a Estradas de Portugal, S.A. (adiante designada por EP, S.A.) no âmbito do estudo Avaliação da Eficácia das Medidas de Minimização de Impactes Ambientais Implementadas em Portugal, desenvolvido pelo Laboratório Nacional de Engenharia Civil (LNEC) e pela Universidade de Évora. Corresponde ao Relatório Final da componente Ruído. Integra uma compilação de todo o trabalho desenvolvido ao longo do período de vigência do estudo, pelo que incluem as actividades efectuadas e apresentadas em relatórios anteriores, bem como as novas componentes realizadas nos últimos meses e que integram os capítulos 4, 5, 6 e 7. Este relatório foi estruturado nos seguintes sete capítulos: Capítulo 1 Introdução; Capítulo 2 Levantamento e caracterização dos sistemas; Capítulo 3 Avaliação da eficácia de várias medidas de minimização; Capítulo 4 Análise dos resultados de programas de monitorização; Capítulo 5 Breve análise custo-eficácia das medidas de minimização de ruído; Capítulo 6 Proposta de directrizes para a orientação da prática para a implementação de sistemas de minimização de ruído; Capítulo 7 Indicação de programas de monitorização.
Year: 2008
Number Pages:
140pp.
Author(s): Antunes, S.; Patrício, J.
Keywords: Ruído; Implementadas em portugal; Impactes ambientais; Medidas de minimização; Avaliação da eficácia
Info
Proposta de medidas para um uso mais eficiente da água nos edifícios
O crescente aumento dos níveis de consumo de água potável em meio urbano, associado a uma cada vez maior escassez dos recursos existentes, quer em termos quantitativos, quer qualitativos, com o consequente aumento do custo da produção para a sua obtenção, deve levar-nos à adopção de medidas que revertam esta tendência. Com o presente documento pretende-se proceder à apresentação de um conjunto de medidas que conduzem a um uso mais eficiente da água nos edificios, sem que no entanto sejam postos em causa, quer o desempenho funcional adequado dos equipamentos, quer os níveis de conforto e de saúde pública a proporcionar aos consumidores.
Year: 2008
Number Pages:
43pp.
Author(s): Pedroso, V.
Keywords: Meio urbano; Consumo de água
Info
Caixilharia de edifícios - Aspectos de segurança e resistência mecânica do vidro
A aplicação do vidro na construção tem sofrido um desenvolvimento acentuado nos anos mais recentes, com a aplicação de vidros com propriedades reforçadas de isolamento térmico, controlo solar, isolamento sonoro, tendo propiciado a aplicação de envidraçados cada vez de maior dimensão. Neste relatório pretende-se sintetizar os aspectos de segurança a que os vidros devem satisfazer, de forma a minimizar o risco de rotura dos vidros e de ferimentos em pessoas, tendo em conta as normas Europeias publicadas nos anos mais recentes. Nesse âmbito, foi efectuado um estudo detalhado do risco de rotura por choque térmico dos vidros para as condições climáticas de Portugal, no sentido de auxiliar na especificação de vidro de elevada resistência ao choque térmico.
Year: 2007
Number Pages:
70pp.
Author(s): Pinto, A.
|
ICT
Info
A iluminação natural nos edifícios - Uma perspetiva no âmbito do conforto ambiental e da eficiência energética
A iluminação natural é inquestionavelmente um dos aspetos fundamentais do conforto ambiental nosedifícios e também um dos aspetos que mais pode contribuir para a sua eficiência energética, desde que seja adequadamente captada e distribuída para os espaços interiores. Adicionalmente, têm vindo a ser demonstrados vários benefícios suplementares que o uso da luz natural possui na saúde e bem-estar dos indivíduos, benefícios estes que não são habitualmente tidos em consideração em abordagens mais tradicionais do uso da iluminação natural nos edifícios. Pretende-se com o presente documento efetuar uma introdução aos temas da iluminação natural nos edifícios numa perspetiva holística tendo como pressuposto fundamental a satisfação do conforto dos ocupantes e a utilização racional da energia nos edifícios.
Year: 2014
Author(s): Santos, A. J.
Keywords: Física e tecnologia das construções; Sustentabilidade; Eficiência energética; Conforto visual; Iluminação em edifícios; Iluminação natural
Info
Janelas e portas pedonais exteriores - Guia para a marcação CE (EN 14351-1:2006+A1:2010)
Neste documento apresentam-se os principais aspectos a considerar para a marcação CE da caixilharia exterior (EN 14351-1:2006+A1:2010) a que se aplica o sistema 3 de avaliação da conformidade. São apresentadas as regras gerais necessárias para a avaliação da conformidade. Indicam-se, nomeadamente, os princípios para a selecção de protótipos a submeter aos ensaios de tipo iniciais (ITT), as formas de racionalizar o número de amostras a submeter a ensaio e as recomendações sobre princípios mínimos de controlo interno da produção em fábrica. Complementa-se esta informação com algumas instruções de fabrico e de instalação da caixilharia em obra, de modo a permitir que as janelas e portas instaladas em obra tenham um desempenho conforme com as características declaradas.
Year: 2010
Number Pages:
93pp.
Author(s): Pinto, A.; Fernandes, O.
Editor: LNEC
Keywords: Europa; Guia; Avaliação; Marca de conformidade; Caixilharia; Porta exterior; Janela
Info
COMPONENTES DE EDIFÍCIOS - Selecção de caixilharia e seu dimensionamento mecânico
No presente documento é apresentada a metodologia de dimensionamento mecânico da caixilharia exterior, tendo por base o Regulamento de Segurança e Acções para Estruturas de Edifícios e Pontes [1], e, no quadro das novas normas europeias, a selecção da caixilharia em função da sua exposição nos aspectos de permeabilidade ao ar, estanquidade à água e de resistência às solicitações do vento. Para além disso, é também especificada a selecção das exigências funcionais de caixilharia relativamente aos aspectos de força de manobra, resistência e durabilidade mecânicas.
Year: 2009
Number Pages:
79pp.
Author(s): Viegas, J.
Editor: LNEC
Keywords: Ensaio não destrutivo; Exigência funcional; Ensaio dinâmico; Ensaio de estanquidade; Ensaio de permeabilidade; Caixilharia; Componentes de edifício; Ensaio mecânico
Info
Instalações elevatórias e sobrepressoras de água para edifícios
No presente documento é feita a apresentação de um conjunto de regras de dimensionamento e concepção das instalações elevatórias e sobrepressoras de água para edifícios. Para cada um dos tipos de instalação elevatória ou sobrepressora referidas, procede-se à apresentação de um pequeno exemplo prático de aplicação, de modo a facilitar a compreensão das regras de dimensionamento apresentadas.
Year: 2009
Number Pages:
70pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Drenagem de águas residuais; Instalação sanitária; Instalação de bombagem; Instalação de edifícios; Rede de drenagem de efluentes; Rede de distribuição de água
Info
Medidas para um uso mais eficiente da água nos edifícios
O crescente aumento dos níveis de consumo de água potável em meio urbano, associado a uma cada vez maior escassez dos recursos existentes, quer em termos quantitativos, quer qualitativos, com o consequente aumento do custo da produção para a sua obtenção, deve levar-nos à adopção de medidas que revertam esta tendência. Com o presente documento pretende-se proceder à apresentação de um conjunto de medidas que conduzem a um uso mais eficiente da água nos edifícios, sem que no entanto sejam postos em causa, quer o desempenho funcional adequado dos equipamentos, quer os níveis de conforto e de saúde pública a proporcionar aos consumidores.
Year: 2009
Number Pages:
39pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Instalação sanitária; Instalação de abastecimento de águas; Instalação de edifício; Utilização da água; Área urbana; Água potável; Consumo de água
Info
Isolamento sonoro a sons aéreos e de percussão - Metodologias de caracterização
Este documento apresenta uma síntese das metodologias disponíveis para caracterização do isolamento sonoro dos elementos de compartimentação dos edifícios, tanto a sons aéreos como a sons de percussão. Nesse sentido, faz-se referência a parte do articulado constante da regulamentação em vigor em Portugal Regulamento dos Requisitos Acústicos dos Edifícios , apresentando-se, ao mesmo tempo, o procedimento integrante da norma internacional aplicável para caracterização do comportamento dos elementos em causa, numa perspectiva de valor único (índice). Complementarmente, apresentam-se algumas noções teóricas de base, visando uma melhor integração na formulação e nos conceitos utilizados, fazendo-se também algumas referências a aspectos construtivos e dando-se possíveis pistas para aprofundamento e desenvolvimento de novas metodologias de caracterização do comportamento acústico em questão.
Year: 2008
Number Pages:
67pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Protecção contra o ruído; Ruído de impacto; Ruído aéreo; Acústica de edifícios; Isolamento acústico
|
|
Outro
Info
BioBuild. D6.4 definitive testing of full-scale demonstration installation test-rigs.
The aim of the BioBuild project is to use biocomposite materials to reduce significantly the embodiedenergy in building facade, supporting structure and internal partition systems, with no increase in cost.This will lead to a step change in the use of sustainable, low carbon construction materials, byreplacing aluminium, steel, conventional FRP materials derived from non-renewable resources (suchas GRP), brick and concrete in new-build and refurbished structures.The result expected for the project is a low cost, lightweight, durable and sustainable biocompositebuilding system, based on panels, profiles, frames and sandwich structures, with full technical andenvironmental validation, which offers low embodied energy for different construction products andkits.Under Work Package 1 of the project, Performance and Standards Requirements, the availablematerials were analysed for basic mechanical performance, environmental impact and compatibility.The appropriate standards and legislation were gathered. These were combined and targets set forperformance, resulting in case study specifications. The results of these tasks were reported in thedeliverables
Year: 2015
Author(s): Tjeerdsma, B.; Pina dos Santos, C.; Pereira, J.; Custódio, J.; Viegas, J.; Grandão Lopes, J.; Patrício, J.; Saporiti Machado, J.; Lina Nunes; Real, L. P.; Rodrigues, M. P.; Domingues, M.; Pontífice, P
Keywords: Testing; Building construction elements; Biocomposites
Info
Acousticork T61
N/A
Year: 2011
Number Pages:
6pp.
Author(s): DED/NAICI
Editor: LNEC
Keywords: Europa; Certificação; Isolamento acústico; Aglomerado de cortiça
Info
Provas de Agregação: Programa de Disciplina
N/A
Year: 2006
Author(s): Patricio, J.
Keywords: Conforto; Acústica; Edificios
|