Papers
Info
Barrier for buildings: analysis of mechanical resistance requirements
Barriers (guardrails and balustrades) prevents people from falling, for example, from balcony, open windows and stairs. Barriers also retain, stop or guide person in buildings. To increase the transparency of these components, traditional materials such as bricks, wood and metal are being replaced by glass or an organic material, which has mechanical behavior different from traditional materials. Regulation usually specify some action to take into account in the design of barriers, but do not define the required resistance. There are no international standards (ISO or EN) to assess the fitness for use of barriers, only national standards, with different testing loading conditions and mechanical resistance requirements. In this paper is presented a comparison of requirements and experimental testing conditions specified in standards from Portugal, Spain, France, UK, USA and Brazil. The goal of this research is to find some equivalence between standards, regarding the mechanical resistance behavior of different materials (brittle/ductile materials) and set a worst case scenario as the basis for the guardrails mechanical resistance profile. Some relations between the service limits state (plasticity) of metal guardrails and maximum deflection are proposed.
Year: 2016
Number Pages:
281-288pp.
Author(s): Pinto, A.; Reis, L.
: Procedia Structural Integrity 1
Editor: ELSEVIER
Keywords: Numerical techniques; Experimental techniques; Case study; Durability; Fatigue; GuardRails
Info
Nexus water energy for hotel sector efficiency
Five and four stars
Year: 2016
Number Pages:
10p.
Author(s): Pinto, A.; Afonso, A.; Santos, A.; Rodrigues, C.; Rodrigues, F.
: Energy Procedia
Editor: ELSEVIER
Keywords: Four and five stars; Hotels; Decrease; Energy; Hidric
Info
On-site assessment of the discharge coefficient of open windows
For assessing the discharge coefficient of an opening it is necessary to measure, as accurately as possible,the flow rate and the corresponding pressure difference that occurs when the fluid passes through it.When the openings are as big as windows applied in common building spaces the open section of thewindow is not negligible when compared with the cross-section of the room. In these conditions, theflow velocity in the room is not negligible and the obstructions (e.g., furniture) are prone to have a higherinfluence on measurements. In addition, the external windows are subject to the wind action, whichmay also impair the measurement. Even though these are not the ideal conditions, they are the commonconditions in which natural ventilation occurs. In this paper, on site measurements of the dischargecoefficient of open windows were carried out and the feasibility of these measurements was evaluated.Two methods were used (flow driven by a fan and flow driven by wind action) and compared. It is shownthat the discharge coefficient of a side-hung casement window with a roller shutter may range fromCd= 0.41 to Cd= 0.81 and that the discharge coefficient of a bottom hung casement window is Cd= 0.84.
Year: 2016
Number Pages:
463-476pp.
Author(s): Teixeira da Cruz, H.; Viegas, J.
: Energy and Buildings
Editor: ELSEVIER
Volume:
126 /2016.
Keywords: Windows flow; Flow rate; Discharge coefficient; Natural ventilation
Info
Saltwater experiments with air curtains for smoke control in the event of fire
Smoke flow inside buildings is a major cause of death in the event of fire. Presently, fire or smoke doors areused, together with smoke control systems, to avoid smoke flowing beyond the boundaries of the firecompartment. In this research, it is proposed the use of downward air curtains to stop smoke flow, whichwill not impair visibility in escape routes. The methodology followed in this research includes: (i) thedevelopment of an analytical model that relates the relevant characteristic quantities of a plane jet with thecharacteristics of the environment in which the fire develops, (ii) small scale experiments with saltwatermodelling to assess the convective parameters that control the smoke tightness of the curtain, (iii) CFDsimulations to assess the performance of a full scale air curtain near a fire source and (iv) fire experiments with afull-scale test specimen. In this paper both the analytical model and the saltwater experiments are presented.Test results confirm that vertical downward air curtains are able to avoid smoke flow through openings andshow a good agreement with the theoretical model for predicting the minimum exhaust rate from the firecompartment. It has been shown that the exhaust flow rate depends on the air curtain flow rate and on the fluidheat expansion due to fire. Test results also make it possible to assess the minimum nozzle velocity to avoidsmoke leakage.
Year: 2016
Number Pages:
243-248pp..
Author(s): Viegas, J.
: Journal of Building Engineering
Editor: ELSEVIER
Keywords: Saltwater modelling; Experiments; Plane jets; Smoke control; Fire safety
Info
A função da luz natural no edificado
No contexto do ano internacional da luz, o artigo descreve as principais funções da luz no edificado
Year: 2015
Number Pages:
44-45pp..
Author(s): Santos, A. J.
: Ingeniunm
Editor: Ingenium Edições, Lda.
Volume:
Nº 147.
Keywords: Iluminação natural; Iluminação
Info
Determinação do teor de CO2 e estimativa de taxas de ventilação em lares de idosos
Determinação do teor de CO2 e estimativa de taxas de ventilação em lares de idosos. Portugal é um dos países mais envelhecidos, sabendo-se que a população idosa apresenta elevada prevalência de doenças crónicas e problemas respiratórios. Diversos estudos indicam que as pessoas desta faixa etária estão, em média, 19 a 20 horas em ambientes fechados. A Qualidade do Ar Interior (QAI) desempenha um papel crucial na qualidade de vida e na saúde dos idosos.
Year: 2015
Number Pages:
71-75pp.
Author(s): Viegas, J.; Aelenei, D.; Nogueira, S .; Sobreira , C.
: Revista Edificios e Energia
Editor: Media Line, Lda.
Volume:
n.º 101.
Keywords: Conforto; Ventilação; Qualidade do ar interior
Info
CO2 Concentration in day care centres is related to wheezing in attending children
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, childrens respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.
Year: 2014
Number Pages:
9pp.
Author(s): Martins, P.; Viegas, J.; Papoila, A .; Aelenei, D.; Caires , I.; Martins , J.; Marques , J.; Cano, M.; Mendes, A.; Virella , D.; Pinto, R.; Pinto , P.; Maesano , I.; Neuparth, N.
: European J Pedriatr
Editor: Publicado online
Keywords: Ventilatin; Kindergarten; Indoor air quality; Environmental health; Children
Info
Eficiência energética e comportamento passivo dos edifícios
Apesar da extensa utilização no léxico técnico, o conceitode eficiência energética nos edifícios sendo fácil deapreender é difícil de quantificar e de utilizar na comparaçãoe classificação de edifícios. A eficiência energéticado edifício é o quociente entre o serviço prestado (confortotérmico, qualidade do ar, água quente sanitária) e oconsumo de energia associado. Resulta, que a eficiênciaenergética depende das características do edifício, dosseus equipamentos de climatização (e todos os outros),mas também dos ocupantes, das suas preferências deconforto e da forma como estes utilizam (ou não) os dispositivose controlos à sua disposição. Este aspeto dosocupantes é decisivo na avaliação da eficiência energéticados edifícios e nas soluções ótimas.Desde o RCCTE de 1990 que a avaliação do desempenhotérmico e energético dos edifícios é realizada comparandoo indicador necessidades térmicas nominais do edifícioface a um valor de referência, admitindo que existe
Year: 2014
Number Pages:
31-36pp.
Author(s): Pinto, A.
: Energuia
Editor: Engenho e Media, Lda.
Volume:
8.ª Edição - maio 2014.
Keywords: Conforto; Comportamento térmico; Reabilitação; Eficiência energética
Info
Environment and health in children day care centres (ENVIRH) - Study rationale and protocl
Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A childrens respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and childrens health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC. © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L. All rights reserved.
Year: 2014
Number Pages:
13p.
Author(s): Martins, J.; Martins, P.; Viegas, J.; Aelenei, D.; Cano, M.; Teixeira, J.; Paixao, P.; Papoila, A .; Pinto , P.; Pedro, C.; Pinto, J.; Maesano , I.; Neuparth, N.
: Revista portuguesa de pneumologia
Editor: Elsevier Doyma
Keywords: Environmental exposure; Children day care centers; Building ventilation; Airway inflamation
Info
Environmental an Ventilation Assessment in Child Day Care Centers in Porto: The Envirh Project
Children attending day care centers (CDCC) have been reported to be more prone to infectious diseases when compared with those cared for at home, and are exposed to conditions that may increase the risk of allergies and asthma. Several studies revealed that consequences of poor ventilation conditions include high levels of carbon dioxide (CO2) and many other indoor pollutants commonly detected in schools. Nine child day care centers were selected randomly to participate in this study. Fifty-two classrooms were assessed for chemical, biological, physical, and allergen parameters in spring and winter seasons in these nine CDCC located in Porto, Portugal. Outdoor measurements were also conducted for comparison. Our results indicated that (i) particulate matter (PM10) median levels were above the national reference levels, both by classroom type and by season; (ii) TVOC kindergarten peak values may raise some concern; (iii) CO2 was present at high median and maximum levels during spring and winter assessment in both nurseries and kindergartens classrooms; (iv) total bacteria concentrations were 57- and 52-fold higher in the nursery and kindergarten than outdoors, respectively, for the spring season; (v) winter and spring median predicted mean vote (PMV) indices were between neutral (0) and slightly cool (? 1) in the thermal sensation scale for comfort situations (?2 to 2) for both types of classrooms; (vi) there were significant differences for both PMV and predicted percentage of dissatisfied (PPD) indices by season; and (vii) CO2, total bacteria, and gram-negative bacteria were associated with low airflow rates. These data will help to evaluate the effectiveness of current building operation practices in child day care centers regarding indoor air quality and respiratory health.
Year: 2014
Number Pages:
931-943pp.
Author(s): Mendes, A.; Aelenei, D.; Papoila, A .; Martins, P.; Aguiar, L.; Pereira, C.; Neves, P.; Nogueira, S .; Cano, M.; Proença, C.; Viegas, J.; Silva, S.; Mendes, D.; Neuparth, N.; Teixeira, J.
: Journal of Toxicology and Environmental Health
Editor: Taylor & Francis Group
Volume:
77 Part A.
Keywords: Children day care center; Indoor air quality; Ventilation
|
Comunicação
Info
Avaliação da estrutura cognitiva dos indivíduos face ao ruído de tráfego rodoviário em zonas urbanas
Na técnica do diferencial semântico, os participantes mostram a posição da sua atitude em relação ao objecto de pesquisa, numa escala de sete pontos, o que permite identificar quer a amplitude quer a direcção da atitude correspondente. As extremidades desta escala de avaliação estão ancoradas num par de adjectivos antónimos e a alternativa neutra está localizada no centro dessa escala de resposta. O resultado para cada participante é a soma das classificações obtidas em todas as escalas para um determinado estímulo, neste caso, sonoro. Neste estudo foram utilizados como objectos, registos áudio de sons de ruído de tráfego existentes em zonas urbanas, designadamente, nas cidades de Lisboa e Porto. Para o efeito foi seleccionado um conjunto de 12 sons, tendo sido efectuada uma análise dos parâmetros físicos e psico-acústicos. A avaliação da estrutura cognitiva dos indivíduos face às fontes de ruído de tráfego, foi iniciada com a determinação do valor modal associado aos 21 pares de adjectivos antónimos utilizados. Este cálculo foi efectuado separadamente para cada som presente no questionário final. De seguida foi efectuada a identificação dos pares de adjectivos aos quais correspondia um valor modal nulo. Na segunda parte do estudo foi efectuada uma análise factorial em componentes principais, de modo a extrair os factores comuns subjacentes aos 21 pares de adjectivos. Esta análise foi realizada conjuntamente para os 12 sons, e separadamente para os sons de tráfego rodoviário, tráfego ferroviário e tráfego aéreo.
Year: 2010
Number Pages:
8p.
Author(s): Antunes, A. L.; Rebelo, M.; Patrício, J.; Samagaio, A.
Editor: LNEC
Keywords: Rodoviário; Tráfego; Ruído
Info
Avaliação da percepção de medidas de minimização para o ruído de tráfego rodoviário em zonas urbanas
Para a avaliação da percepção de medidas de minimização de ruído de tráfego rodoviário em zonas urbanas foi desenvolvido um inquérito que envolveu, numa primeira fase, a realização de um inquérito piloto onde foram recolhidas informações a partir de entrevistas semi-estruturadas de resposta aberta. Tendo em conta as informações recolhidas, foi construído um questionário com a finalidade de avaliar a estrutura cognitiva dos indivíduos face às fontes de ruído de tráfego presentes em zonas urbanas [1]. Nesta comunicação serão discutidos alguns aspectos importantes para a percepção de medidas de minimização de ruído, tais como a exposição diária a que o indivíduo está sujeito, para além de outros tipos de poluição para os quais a fonte em consideração pode contribuir (como por exemplo a poluição atmosférica, odores). Os aspectos individuais, como por exemplo, o contexto sócio-habitacional, a sensibilidade ao ruído e o grau de escolaridade podem também contribuir para a incomodidade induzida pelo ruído, bem como para a formação de atitude geral face à fonte de ruído em análise (importância da fonte, grau de utilização). Finalmente, serão também discutidos os principais efeitos induzidos pelo ruído, bem como a avaliação de estratégias para lidar com este aspecto (estratégias de coping).
Year: 2010
Number Pages:
8p.
Author(s): Antunes, S.; Rebelo, M.; Patrício, J.; Samagaio, A.
Editor: LNEC
Keywords: Rodoviário; Tráfego; Ruído
Info
Depicting Residential Night Flow
This article presents the results of studies conducted in three different localities in São Paulo with the intention of obtaining the intake times in single-family and multifamily economies. Measurements were made through the use of equipment for data acquisition instrumentation and water meters. The resulting data were treated to obtain information about the specific water consumption and the residential minimum night flow (MNF). The monitored residences are located in areas west and east of Sao Paulo city. The results pointed out the values of minimum night flows for two types of buildings: homes (one storey) and apartments (multistory). For residences the average MNF was 2,34 L/h. For apartments the average MNF was 2,7 L/h. Both were recorded at 3:00 am. In a study conducted in Spain, these values of MNF were 4,0 L/h for homes and 8,0 L/h for apartments and these occurred between 3:00 and 4:00 pm. For the home was monitored the points of use and could be identified the sanitary appliances that were used by residents in the schedule which includes the NMF (2:00 5:00). The devices most commonly used at this time were: the shower and lavatory faucet. Observations on the values found indicate that there are real uses of sanitary appliances in homes and there are still portions of consumption to be identified that may be due to leaks that can be avoided through education campaigns. It was also the occurrence of flow in the limit of very small flow of water meters transition entailing the systematic occurrence of sub-metering that can affect the calculation of apparent losses.
Year: 2010
Number Pages:
8p.
Author(s): Barreto, D.; Pedroso, V.; Chahim, R.
Keywords: Sanitary appliances water consumption during night flow; Domestic water consumption; Residential end uses of water; Residential night flow water consumption pattern
Info
Desempenho de Sistemas de Ventiladores de Impulso para Controlo de Fumo em Parques de Estacionamento Subterrâneos
O sistema de controlo de fumo baseado em ventilação de impulso constitui uma nova solução, que tem sido aplicada a parques de estacionamento subterrâneos, que pretende limitar o escoamento do fumo proveniente de um foco de incêndio sem que seja necessário recorrer à implementação de compartimentação. Nesta comunicação pretende-se dar a conhecer as exigências específicas relativas à concepção e dimensionamento deste tipo de sistemas.
Year: 2010
Number Pages:
13p.
Author(s): Viegas, J.; Teixeira da Cruz, H.; Pedroso, V.; Virgílio, A.
Editor: LNEC
Keywords: Parques de estacionamento cobertos; Incêndio; Controlo de fumo
Info
Diffraction edges perceived efficiency
Today, noise barriers are recognized as the most effective noise minimization measures of road traffic noise near sensitive receptors located in the road surrounding areas. Especially where the urban occupation is characterized by buildings of low height. For higher buildings noise barriers can not be a completely effective solution. One of the additional measures to increase efficiency may consist of placing, on top of noise barriers, an edge for reducing diffraction more efficiently without significantly increasing its height. We present a case study in which diffracting edges were place few years after the implementation of noise barriers, and through the relationship between sound attenuation and noise perception it is possible to conclude that the benefits in population of this intervention are higher than expected.
Year: 2010
Number Pages:
7p.
Author(s): Domingues, M.; Antunes, S.; Ramos, I.; Grilo, A.
Editor: LNEC
Keywords: Diffraction edges; Noise barriers; Noise perception
Info
Impulse ventilation in underground car parks: The influence of parked cars in smoke control
Impulse ventilation systems (IVS) are used to provide ventilation for underground car parks and to control the smoke in the event of fire. In this paper, the influence of the parked cars in the smoke control is studied using CFD simulations. A sensitivity analysis, considering important parameters as the number of parked cars and the height of the car park, is carried out. The results from a simplified analytical model for the flow field near the ceiling are compared with CFD simulations. It is shown that the obstruction caused by parked cars reduces the smoke control flow rate and the average velocity of the flow; therefore, it reduces the efficacy of the smoke control. It is also shown that the simplified model is able to reproduce approximately the boundary of the smoke. This simplified model is intended to support a first approach of the design of IVS.
Year: 2010
Number Pages:
15p.
Author(s): Viegas, J.
Keywords: Cfd; Smoke control; Jet fan; Underground car park; Impulse ventilation
Info
Inside building water consumptions for promoting rational use
ABSTRACT: This paper presents the results of a survey on domestic water consumption inside buildings covering some countries in European and American continents, namely Portugal, United States of America USA and Brazil. A survey in literature was performed focusing information on water consumption for urban use, and then to those based on studies and measurements on real use, so that consumption compiled data would represent as closest to the real. Some studies were identified and in which one was found the percentage of water consumed in the various activities carried out within the buildings, either by simple activities performed by residents, as well by appliances that add up the heaviest services automatically (dish and clothes washers). The data analyses enabled a comparison with different internal water uses, thus supporting a classification of use in a manner to be possible to highlight those that must be supplied with potable water from those that do not require non-potable water. It was reported, on average, that 75% of domestic consumption in homes can be provided by potable water and another 25% likely to use non-potable water. In conclusion it is noted that for the first part of residential water consumption there is a range of possibilities to promote the rational use of water by adopting measures involving design, saving water equipment and educational campaigns. For the second part it was highlighted the use of rainwater as an alternative.
Year: 2010
Number Pages:
9.
Author(s): Barreto, D.; Pedroso, V.
Editor: LNEC
Keywords: Promotion rational use; Building water
Info
Potential use of rainwater and reclaimed water in residential buildings
ABSTRACT: This paper presents the results of a study conducted in Portugal and Brazil about rainwater and reused water potential use inside buildings. The study was based on field surveys conducted in both countries where water consumptions measurements were performed in some houses with purpose to identifying the parcels that make up water consumption requested by the use of domestic appliances for attendance of its users. A water use tendency is presented considering a scarcity scenario and consumption per capita in both countries as an aid to understanding the importance of the theme for water resources preservation. It is shown researches results carried out in Brazil and Portugal where a collection of internal water use for domestic purposes inside buildings are presented and defined as a set of actions for reducing of water consumption and especially dedicated to carrying out a calculation of the potential use of rainwater in buildings (particular for toilets). Considering the residential water profiles it was identified which part could be supplied by rainwater and the essential part exclusively supplied with drinking water. From this perspective was performed some calculations to find out the water savings by using rainwater for domestic purposes and which appliances inside buildings are eligible to be supplied. As complementary and considering that waste water generated by some appliances (showers) it was performed the calculations including the wastewater reclaimed inside buildings. The study finds out an average of drinkable water savings of 28 to 100 % for WC cisterns using rainwater and reclaimed water. Some other savings are presented according to sanitary appliance and inside or outside house activities when rain and reclaimed water were used.
Year: 2010
Number Pages:
10p.
Author(s): Barreto, D.; Pedroso, V.
Editor: LNEC
Keywords: Water in residential buildings; Use of rainwater
Info
Rainwater use in low income housing
ABSTRACT: This paper presents the results of a study conducted in low income housing (Social Housing Buildings) in order to identify the potential use of rainwater, considering the two types of houses built up by a state company that provides large scale low income housing in the state of Sao Paulo, Brazil. It was studied the water consumption of sanitary appliances and was identified which appliances could be supplied by rain water. Following, were selected two main types of houses among all housing built: one level storey houses and multi-storey buildings (apartments). These types of houses are located in different cities in Sao Paulo state. Next step was a weather study about two cities in order to find out the rain periods quantities and frequency. Based on a methodology cited by Brazilian standard, but very similar to European practice for designing volumes of rainwater capture, it was done a balance of water needed to supply the sanitary appliances for each house type. A series of calculations were performed and it was found the water volumes needed to supply the houses related to percentage water economy and its contribution along drought season. In terms of potential water volume saved was found that rainwater can be used in one storey house for WC cistern flush and clothes wash machine remaining 1,92 m3/month and reaching an economy of 1.063,8 m3/year, for 45 units studied and a saving of 5.977 US$ per year. For apartment buildings there were two findings: one with rainwater reservoirs at ground level and the rain water pumped up to be used for WC cistern and clothes wash machine yielding a year economy of 5.068,8 m3. Another finding was that the rainwater is reserved in the roof level, feeding only WC cistern. This alternative comes up a year economy of 4.630,08 m3. In monetary terms it represents savings respectively of 15.933 US$ and 14.500 US$ per year. The results pointed out the feasibility in terms of rainwater volumes to be used and identified the relationships between volumes of necessary rainwater and complementary potable water in percentage terms, so resulted in compatible reservoir sizes for use without affecting the building structures or costs. Also, some design options for rainwater systems for each kind of type buildings were developed.
Year: 2010
Number Pages:
11p.
Author(s): Barreto, D.; Kinker, R.; Pedroso, V.
Editor: LNEC
Keywords: Income housing; Use in low; Rainwater
Info
Redesign of Exhaust Systems for Naval Gas Turbines: Usage of a New Cr-Mn Austenitic Stainless Steel
Abstract. Studies performed earlier show that the thermal shock loading has influence, together with the normal service loadings, in the fatigue life of some critical welded joints present in the exhaust systems of naval gas turbines [1-2]. In order to prevent the fatigue crack propagation that was verified in service [3], a recently developed ultrahigh-strength austenitic stainless steel was selected (Cr-Mn steel - number 1.4376) and its mechanical properties and the fatigue resistance are under study. This new material could replace, locally, the current material used in the main structure of the exhaust system (AISI 316L). Experimental data are shown. The temperature measured at the critical locations was about 350ºC and the pressure applied in the system was calculated through a Computational Fluid Dynamics simulation (CFD), whose results are presented in the paper. The stresses induced by the loadings will be important to estimate the lifetime from the fatigue resistance tests (S-N curves) that will be performed, at 350ºC, in butt and T-welded joints of AISI 316L stainless steel with Cr-Mn austenitic stainless steel.
Year: 2010
Number Pages:
497-503pp.
Author(s): Teixeira da Cruz, H.; Martins, R.; Viegas, J.; Aveiro, J.
Editor: Materials Science Forum Vols. 636-637
Keywords: Computational fluid dynamics; Aisi 316l; Cr-mn austenitic stainless steel
|
Books
Info
Weathering of Polymers and Plastic Materials
This book presents the state of the art on the weathering of polymers and plastic materials in outdoor applications, comprising natural weathering, accelerated climatic weathering, laboratory artificial accelerated weathering, and lifetime prediction methodology. It summarizes the most suitable methods of instrumental analysis to access and quantify (when possible) degradation caused by weathering, while also covering the degradation and stabilization of polymers based on environmental and artificially induced factors. Innovative polymer additives and some developments in polymeric materials designed for outdoor applications are also included, emphasizing a few selected cases. the book intends to be an important reference source for those involved in the study of the durability of polymers and plastics, production of plastics for exterior applications, chemists responsible for quality control of plastic products, and researchers and students across plastics engineering, polymer science, polymer chemistry and environmental science.
Year: 2023
Number Pages:
XXIV, 136.
Author(s): Real, L. P.
: Weathering of Polymers and Plastic Materials
Editor: SPRINGER NATURE
Keywords: Lifetime prediction; Correlation; Durability; Polymer degradation; Polymer stabilization; Plastics; Artificial weathering; Climatic weathering
Info
Recycled Materials for Construction Applications - Plastic Products and Composites.
In this work, a general approach to the recyclability of plastics and composites used in construction, with the purpose of their reuse, is made.The various recycling technologies applicable to the plastic materials, most used in construction, and their various stages are described, detailing for the main polymers, and indicating the difficulties inherent in these processes. In this context, several Illustrative cases of success and examples of recent technological innovation are presented.It also addresses the issue of quality control, certification, and standardization adopted in Europe for recycled plastics.Some market data are presented, namely the production capacity, data for bio-based plastics and polymers, the quantities of recycled plastic and, for each type of polymer, statistics data on recycling and market barriers of recycled materials, also referring to the variables that most influence recycling costs and the price of recycled materials.The conclusions drawn from this work are of several types. In a succinct way, they demonstrate that recycling is a fundamental resource to minimize waste and reduce environmental pollution, constituting a strategic approach to the management of waste from plastic construction products at the end of its useful life.The main challenges and future perspectives that arise from the most recent developments in this area are made.Finally, the most relevant strategic recommendations are presented in order to continue and concretize the resolution of the problem of recycling plastics and seek to achieve the objectives of the circular economy, which involves the development of the specialized market for recycling and recycled plastics and, consequently, promote the purchase and sale operations of economic agents and interested parties (sellers, buyers, consumers, associations, recyclers, manufacturers of production machinery, etc.) in order to also increase the recycling and recyclability of plastic waste.
Year: 2022
Number Pages:
1-162.
Author(s): Real, L. P.
: Recycled Materials for Construction Applications - Plastic Products and Composites.
Editor: Springer
Keywords: Environmental impact; Recycling; Circular economy; Construction; Sustainability; Composites; Plastics
Info
Método LNEC para avaliação e classificação da qualidade acústica de edifícios habitacionais
Esta publicação apresenta uma metodologia para avaliar a qualidade acústica de edifícios habitacionais, ou partes deles (fogos), visando a sua qualificação em termos das características da componente acústica interior, nos espaços com utilização sensível, contribuindo, consequentemente, para a sustentabilidade ambiental e para o reforço dos padrões de qualidade de vida do cidadão. A metodologia proposta assenta num processo de avaliação segundo três linhas estratégicas fundamentais, às quais corresponde um determinado nível físico, respetivamente: uma relacionada com a integração da unidade edificada no seu ambiente próximo (ou seja, tendo em conta um contexto de planeamento), designada na presente publicação por Vizinhança; outra relacionada com a disposição interior dos diversos espaços funcionais e com a sua inter-relação cruzada, assim como com os diferentes usos que podem estar associados às diversas frações autónomas existentes (ex. fogos versus espaços comerciais), para além das caraterísticas acústicas dos espaços comuns, a qual é intitulada Edifício; e uma outra assente na eficácia acústica das soluções de compartimentação adotadas e no nível máximo admissível do ruído de equipamentos de uso coletivo, designada por Habitação. Por último, apresentam-se, a título de exemplo, algumas casos práticos que possibilitam demonstrar a potencialidade, as nuances, e o interesse de que se pode revestir o uso da metodologia em causa para classificação, e eventual etiquetagem, da qualidade acústica das unidades habitacionais, potenciando assim a qualidade correspondente e introduzindo um novo parâmetro de valoração de mercado.
Year: 2013
Number Pages:
77pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Conforto acústico; Avaliação; Controle de qualidade; Edifício de habitação; Acústica de edifício
Info
IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia
A IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia (MEFTE 2012) contempla diversas áreas temáticas onde métodos experimentais, analíticos e numéricos contribuem para o progresso nestas áreas científicas. Esta conferência é uma organização conjunta entre o Laboratório Nacional de Engenharia Civil (LNEC), a Universidade Nova de Lisboa (UNL), o Instituto Superior de Engenharia de Lisboa (ISEL), o Instituto Superior Técnico (IST), a Faculdade de Engenharia da Universidade do Porto (FEUP) e a Universidade de Coimbra (UC), sob os auspícios da Associação Portuguesa de Mecânica Teórica, Aplicada e Computacional (APMTAC). A APMTAC promove bienalmente esta conferência nacional temática, como um dos seus objectivos estratégicos e estatutários, no âmbito da mecânica dos fluidos, termodinâmica e energia. Na sequência do sucesso das conferências anteriores (2006 FCT-UNL, 2008 U. Aveiro, 2009 Instituto Politécnico de Bragança), a IV Conferência Nacional é realizada nas instalações do Laboratório Nacional de Engenharia Civil, nos dias 28 e 29 de Maio de 2012. Foram inicialmente submetidos 111 resumos de investigadores portugueses e estrangeiros, dos quais resultaram 80 comunicações que foram submetidas a avaliação. A Comissão Organizadora manifesta o seu apreço e agradece a todos os que contribuiram para a realização deste evento, em especial, aos membros das Comissões Científica e Executiva pelo seu esforço e dedicação, assim como a todos os autores e participantes. Agradecemos ainda aos oradores convidados para as sessões plenárias pelo seu contributo em tornar esta conferência um lugar de partilha de conhecimentos do estado da arte da mecânica de fluidos, termodinâmica e energia. Finalmente agradecemos aos nossos patrocinadores o seu apoio à realização desta conferência.
Year: 2012
Number Pages:
192pp.
Author(s): entidade LNEC
Editor: LNEC
Keywords: Congresso; Energia; Termodinâmica; Mecânica dos fluidos; Pt
Info
Road Tunnels: Operational strategies for emergency ventilation
Le présent document est un rapport préparé par le groupe de travail n° 6 « Ventilation et maîtrise des incendies » du comité technique C3.3 'Exploitation des tunnels routiers' de lAssociation mondiale de la Route (AIPCR). Ce rapport fournit des informations sur lexploitation des systèmes de ventilation des tunnels dans les cas durgence, principalement ceux causés par un incendie. En exploitation normale, la ventilation est nécessaire pour assurer la propreté de lair ambiant et préserver la visibilité dans le tunnel, en évitant laccumulation de gaz polluants et de particules. En cas dincendie, lexploitation de la ventilation doit être modifiée pour passer de son mode normal à un mode qui optimise les possibilités dévacuation des usagers du tunnel et dintervention sûre des services durgence. La stratégie à adopter dépend de la géométrie spécifique du tunnel, de la densité du trafic et de son mode de circulation uni ou bidirectionnel. Après une discussion des travaux antérieurs de lAIPCR et quelques remarques sur la directive européenne de 2004 et les recommandations nationales concernant la ventilation des tunnels, le rapport présente des informations sur les types de système de ventilation communément utilisés, tels que les systèmes longitudinal, transversal et semi-transversal. Les objectifs visés dans lidéal pour la maîtrise des fumées dans ces différents types de tunnel sont ensuite traités, et le mode de commande préféré est présenté. Ceci peut inclure, par exemple, le contrôle de la vitesse du courant dair longitudinal, une fonction qui peut ne pas être disponible dans tous les cas, mais qui devrait normalement être prévue dans un ouvrage nouveau. Les principes de la commande de la ventilation sont alors décrits dans leurs grandes lignes, et quelques remarques sur la maintenance et les essais de vérification suivent.
Year: 2011
Number Pages:
99p.
Author(s): Allemann, M.; Brandt, R.; Carlotti, P.; Viegas, J.
Editor: PIARC
Volume:
2011R02.
Keywords: Controlo de fumo; Ventilação; Túneis
Info
Sistemas de combate a incêndios em edifícios - De acordo com a nova regulamentação
Com o advento da nova regulamentação de segurança contra incêndios em edifícios, e tendo em conta a importância da mesma na segurança das pessoas e bens, pretende-se com este documento colocar à disposição dos projectistas, alunos de engenharia e de todos aqueles que se relacionem de alguma forma com a temática dos sistemas de combate a incêndios com água em edifícios, uma súmula das partes mais relevantes do regulamento, destinadas a este fi m, bem como a apresentação de metodologias de cálculo, adequadas, que facilitem a compreensão e aplicação destas, no sentido da obtenção de projectos que conduzam à produção de sistemas com níveis de desempenho funcional satisfatório.
Year: 2010
Number Pages:
74pp.
Author(s): Pedroso, V.
Editor: LNEC
Volume:
NS 117 Não Seriados.
Keywords: Protecção dos edifícios contra o fogo; Segurança contra incêndios
Info
A acústica nos edifícios. Pavimentos e revestimentos de pavimentos, isolamento a sons de percussão
As exigências relativas às condições acústicas dos edifícios encontram-se definidas no Regulamento dos Requisitos Acústicos dos Edifícios, aprovado pelo Decreto-Lei nº 129/2002 de 11 de Maio, com as alterações introduzidas pelo Decreto-Lei n.º 96/2008 de 9 de Junho. A necessidade de conhecimento das características de isolamento a sons de percussão, de diferentes soluções, na elaboração dos projectos de condicionamento acústico, fundamenta o objectivo desta publicação e é consubstanciado pela compilação de resultados de diferentes soluções obtidos em laboratório. No sentido de contextualizar a informação disponibilizada, referem-se os conceitos gerais, os parâmetros característicos e a terminologia utilizada, assim como as variáveis que condicionam o desempenho dos elementos de separação horizontal à transmissão de sons de percussão. É ainda apresentado um exemplo de estimativa das condições de isolamento a sons de percussão, usando o método simplificado constante da norma EN 12354-2:2000 Building Acoustics Estimation of acoustic performance of buildings from the performance of elements Part 2: Impact sound insulation between rooms.
Year: 2009
Number Pages:
133pp.
Author(s): Domingues, M.
Editor: LNEC
Keywords: Revestimento de pavimento; Pavimento de edifício; Isolamento acústico; Acústica de edifício
Info
Projecto de condicionamento acústico de edifícios
A Acústica apresenta um carácter diagonal no domínio do conhecimento científico, o que pode determinar dificuldades na abordagem de áreas específicas, como seja o domínio do condicionamento acústico de edifícios. Há também a considerar o facto de serem muito reduzidas as potências postas em jogo na audição humana, apesar de este sentido ser muito importante no diálogo do Homem com o Ambiente. Afigurou-se oportuno, face ao quadro esquissado, congregar, de modo ordenado, elementos entendidos como necessários para o desenvolvimento de estudos de engenharia no domínio do condicionamento acústico de edifícios. Não está em causa um pretenso tratado nem um vade-mécum de Acústica aplicada, mas um instrumento com interesse para quem pretenda exercer actividade de Engenharia Acústica, no projecto de condicionamento acústico de edifícios.
Year: 2009
Number Pages:
76pp.
Author(s): Silva, P. M.
Editor: LNEC
Keywords: Nível sonoro; Conforto acústico; Acústica de edifícios
|
|
Tese de Doutoramento
Info
Utilização de ventilação de impulso em parques de estacionamento cobertos
A aplicação da ventilação de impulso em parques de estacionamento cobertos tem conhecido uma grande expansão em Portugal no último decénio. Este tipo de ventilação baseia-se na utilização de um conjunto de ventiladores axiais, suspensos no tecto do parque de estacionamento, que gera um escoamento adequado para promover o varrimento entre a admissão de ar novo e a exaustão, normalmente realizada por ventiladores axiais periféricos, de forma a assegurar o escoamento para o exterior dos poluentes emitidos pelos veículos. Na condição de incêndio este sistema de ventilação é utilizado para limitar o escoamento do fumo no interior do parque de estacionamento coberto e também para promover o seu escoamento para o exterior. Neste documento é feita uma síntese crítica do conhecimento neste domínio utilizando o levantamento do estado do conhecimento nas matérias relevantes para estabelecer recomendações de concepção e de dimensionamento de tais sistemas. Este documento também identifica as necessidades de investigação neste domínio, detalha o conteúdo dos projectos de investigação que devem ser realizados, estabelece as bases da sua coordenação através de um programa de investigação de forma a ser possível criar sinergias e identifica as oportunidades de formação pós-graduada, apoiadas nesse programa de investigação.
Year: 2009
Author(s): Viegas, J.
Info
Aplicação da avaliação de ciclo de vida à análise energética e ambiental de edifícios
O impacto energético e ambiental dos edifícios é cada vez mais importante nas sociedades contemporâneas, pelo consumo de energia e de recursos durante a fase de utilização dos edifícios, mas também pelas fases de construção e demolição. Encontra-se comprovado que os edifícios são responsáveis por cerca de 46% do consumo de energia primária no concelho de Lisboa, mas não se encontra apreciado o impacte da fase de construção e demolição. No âmbito desta tese aplicou-se a metodologia de análise do ciclo de vida a edifícios, desde a fase de construção até à demolição, com o objectivo de avaliar os impactes ambientais directamente relacionados com o edifício, em particular avaliar as possíveis interacções entre a fase de construção e a fase de utilização. Para efectuar a análise do ciclo de vida foram inicialmente definidos os aspectos de conforto ambiental interior a satisfazer. Foram avaliados os impactes ambientais associados ao fabrico e à utilização de alguns materiais de construção e de instalações de edifícios de forma a possibilitar a ACV. Tendo em conta o impacte dos envidraçados nas necessidades energéticas na fase de utilização dos edifícios, foi efectuada a avaliação de diferentes soluções envidraçadas de forma a estabelecer áreas de vidro optimizadas que minimizem as necessidades energéticas de aquecimento, arrefecimento e iluminação. Foi avaliada experimentalmente a permeabilidade ao ar de edifícios Portugueses e foi avaliado o impacte da permeabilidade nas infiltrações de ar e nas necessidades de climatização para diferentes tipos de sistemas de ventilação, sendo apresentada uma proposta de limites a adoptar para os edifícios Portugueses. Por fim a metodologia de ACV do edifício foi aplicada a casos de estudo sendo evidenciado que o impacte ambiental dos edifícios vai para além do consumo de energia na fase de utilização, pois a fase de construção de edifícios novos e de fim-de-vida pode corresponder a sensivelmente 30% do impacte ambiental do edifício. Se for considerado apenas a construção, fase de fim-de-vida e a energia para climatização, o impacte ambiental da construção é de sensivelmente 90% para o caso de Lisboa. Nos casos de estudo foi evidenciado que existe um ponto de optimização do nível de isolamento térmico dos elementos opacos a partir do qual as poupanças de energia associadas ao incremente da espessura do isolante térmico não compensam a carga ambiental nele incorporada. Por outro lado para reduzir o impacte ambiental dos edifícios é evidenciado que a concepção de edifícios que prevejam a reutilização dos elementos de construção mais pesados tem um peso que é cerca do dobro do associado à optimização do isolamento térmico do edifício.
Year: 2008
Author(s): Pinto, A.
Keywords: Qualidade do ambiente interior; Declaração ambiental; Ciclo de vida; Eficiência energética; Edifícios; Sustentabilidade
|
Dissertação de Mestrado
Info
Projecto de desenvolvimento tecnológico de condutas de evacuação de produtos da combustão de turbinas a gás utilizadas para propulsão naval
Nos sistemas de evacuação dos produtos da combustão de turbinas a gás, utilizadas na propulsão naval de alguns navios de combate, tem-se verificado a ocorrência de nucleação e propagação de fissuras através das paredes de pressão do sistema, tendo as principais fissuras propagando-se a partir dos pés dos cordões de soldadura. A conduta do sistema em estudo é constituída num aço inoxidável austenítico, AISI 316L (N), designado pela norma EN 10088-1 por 1.4404, com uma espessura de aproximadamente 3,7 mm. Em estudos anteriores foi medida a temperatura exterior da parede de pressão da conduta, tendo-se registado 350 ºC na zona junto ao anel de suporte inferior. No presente trabalho, e com o intuito de se proceder a uma substituição localizada do material constituinte da conduta, foram realizados estudos metalográficos comparativos entre o aço inoxidável austenítico 1.4404 e o aço inoxidável austenítico 1.4376, tendo-se também efectuado a determinação da composição química dos mesmos. Definiu-se a geometria dos provetes de fadiga e de fluência (e tracção), tendo neste último sido determinado a carga máxima de ensaio e a sua verificação pelo método de elementos finitos. O trabalho foi concluído com a modelação numérica do escoamento do fluido, num programa de diferenças finitas comercial, para a determinação do campo de pressões e temperaturas actuantes na conduta.
Year: 2008
Author(s): Cruz, H.
Keywords: Modelação cfd; Aço inoxidável 1.4376; Aço inoxidável 1.4404; Turbina a gás; Conduta de evacuação dos produtos da combustão
|
Relatório Científico
Info
Controlo de fumo por meios ativos e evacuação de locais de risco - Contribuição para o método de análise de risco de incêndio em edifícios existentes (MARIEE)
O LNEC iniciou no primeiro trimestre de 2013 o desenvolvimento dum Método de Análise de Risco deIncêndio em Edifícios Existentes (MARIEE). Esse método tem como objetivo constituir, no futuro, umaalternativa à aplicação da atual legislação de segurança ao incêndio nas operações de reabilitação deedifícios. Na composição do MARIEE surge um coeficiente designado de consequências, quer para os locaisde risco quer para as vias de evacuação. Essas consequências resultam de um balanço entre o perigo, representado por diversas manifestações associadas ao incêndio (aumento de temperatura, presença de gases tóxicos, fumo, etc.) e pela exposição a essas manifestações. No MARIEE as consequências são determinadas, separadamente, para os locais, para as vias horizontais e para as vias verticais de evacuação. Neste documento apresenta-se um estudo de apoio ao desenvolvimento do MARIEE no que se refere à determinação das consequências nos locais de risco dotados de meios ativos de controlo de fumo,considerando um índice de ocupação igual a 0,5 pessoas por m2.
Year: 2015
Author(s): Viegas, J.; Leça Coelho, A.
Keywords: Legislação; Edifícios existentes; Evacuação; Controlo de fumo; Risco
Info
BioBuild Project Deliverable Report 3.5
The overall aim of the BioBuild project is to create a set of new bio-composite construction systems that can replace high-embodied energy materials by significantly improving the environmental impact and sustainability of the building industry. The project aims to fulfil this goal by introducing and broadening the use of bio-composite material systems in order to reduce the overall embodied energy associated to facades, supporting structure and internal partition systems by at least 50 % over benchmark solutions. The result of the project would be a set of low cost, lightweight, durable and sustainable biocomposite building systems for both new-build and refurbished structures, based on panels, profiles, frames and sandwich structures, with full technical and environmental validation. Throughout the project, and particularly within WP 2 and 3, the natural fibres have been optimised in terms of mechanical performance as well as surface treatment, while the resins have been tailored to achieve the best durability and compatibility with the reinforcements, as well as improved resistance to biodegradation. In general the materials have been optimized to improve other relevant performance such as: mechanical performance, fire resistance, biodegradation resistance, fibre-matrix interface, so that they can be used in a wide range of building components.
Year: 2014
Number Pages:
36p.
Author(s): Stevenson, A.; Pina dos Santos, C.; Carra, G.; Pereira, J.; Custódio, J.; Viegas, J.; Patrício, J.; Ribeiro Nunes, L. M.; Real, L. P.; Veras, M.; Rodrigues, M. P.
Editor: LNEC
Keywords: Building construction elements; Bio-composites
Info
Estudo sobre cálculo dos níveis óptimos de rentabilidade dos requisitos mínimos de desempenho energético dos edifícios e componentes de edifícios - Contribuições para o estudo dos edifícios de escritó
No âmbito das preocupações com a eficiência energética dos edifícios e com as exigências decorrentes do estabelecimento de requisitos mínimos de desempenho energético dos edifícios, baseados em níveis ótimos de rentabilidade em conformidade com as exigências da Diretiva 2010/31/EU recast, o LNEC colaborou na realização do estudo Português aplicável aos edifícios novos de comércio e serviços. Neste relatório, reúne-se parte das contribuições do LNEC para o estudo de edifícios de escritórios novos e apresentam-se as principais conclusões.
Year: 2014
Author(s): Pinto, A.
Keywords: RECS; Energia; EPBDrecast; Custo ótimo; Eficiência energética
Info
D 6.1 Interim biocomposite evaluation review
This deliverable is a review report which evaluates the progress and feasibility of the biocomposite systems, designs and installations, taking into account the information resulting from the work developed in the aim of Biobuild project. The main steps followed in the project up to this moment to develop bio-systems with such characteristics can be summarized as follows: · Use of additives and modifications to create durable natural fibres. · Use of additives and modifications to create durable bio-based resins. · Combine the improved resin and fibres to create durable and strong biocomposites. · Combine the improved natural fibres, resins and core materials to make composite components having mechanical properties, durability and functionality suitable for the selected construction applications. · Produce panels, profiles and sandwich structures for the selected construction applications. In terms of baseline resin/fibre properties, it was concluded that for both fibre reinforced composites (flax and jute fibre reinforced UP and epoxy composites) the increased moisture absorption is accompanied by a decrease in longitudinal stiffness and strength and by an increased plasticity, leading to an increase in longitudinal strain-to-failure. In general, the longitudinal stiffness of flax fibre composites decreases to 1/2 of its initial value, whereas that of jute fibre composites only goes down to 1/3 of its initial stiffness. On the other hand, the longitudinal strength of jute fibre composites is decreased by 1/4 after immersion, while that of flax fibre composites is only decreased by 15 %. Finally, for both fibre composites, the longitudinal strain-to-failure is increased by around 50 %. After the completion of the flax preforms benchmarking, these observations were made: · No significant difference between the different UD preforms tested in longitudinal direction. · The higher value of the transverse tensile strength for the Procotex UD is mainly due to the binding yarns. · Jute preform, as shown in the previous section, has lower property values than flax, but will still be relevant for low cost and non-structural parts. The same conclusion applies for the mat preform. · Tensile testing is defect sensitive which may explain the variations in results. Concerning the effect that fibre treatments have on the durability and moisture resistance, it was concluded that: · Quality of the samples makes difficult (impossible) to measure the effect of fibre treatment on the properties of the composite boards. · Water uptake is the main technical drawback for biocomposites. · Sealed edges and coating are other possibilities to improve the properties. · Jute is more water resistant; further examination is required for composites used in outdoor conditions. · None of the fibre treatments has a clear positive effect on the properties (water uptake nor strength) of the composite boards. · Research on fibre treatment within the project is needed for fundamental understanding and examining the possibilities for the future. The ongoing work in WP3 consists essentially in refining the processability of the various sandwich configurations in order to optimize the process parameters (time, temperature, pressure, degasification cycles, etc.) and to minimize rejections and wasted material (either BioBuild Project Deliverable Report 9 CONFIDENTIAL from a failed production cycle or from corrections in final dimensions) with the target of obtaining panels that are fit for the tasks they are intended for. Currently, the work on this task is far from finished, since on one hand problems regarding medium scale production are yet to be solved and on the other hand this is a task which should follow the development of the products, especially if, in the testing phase (including the Single Burning Item test and other equally important tests), it is found that any of those sandwich panel configurations need to be adjusted in order to comply with the target technical requirements. The main conclusion drawn from the processing of furan resin and glass fibres can be summarised as follows: · Furan resins have a very low reactivity (which can be increased) which means that pultrusion speed should be very low, making the process not economically viable from an industrial point of view. · The acid catalyst required to cure the resins and the high processing temperature required for the production induces fibre degradation and corrosion of steel parts in the production equipment. The action of acids can cause hydrolysis in cellulose chains and other binding materials, thereby degrading the fibre bundle mechanical properties. · It was therefore evident that this furan resin was unsuitable for use with natural fibres due to the acidic catalyst used to cure it. From the processing point of view, the first results of bio-polyester resins in combination with flax fibres can be summarized as follows: · The processing conditions for bio polyester resin are very similar to that of traditional resins, therefore similar pultrusion speed and heating temperature are used and similar resin stability are obtained. · The main drawbacks arise from the natural fibres. Dry natural fibres, when compared to glass fibre show fibre buckling, fibre rupture and fibre blockage near and in the mould. · In order to solve these issues, zinc stearate was added to the formulation and better results were obtained. More tests are underway to determine the proper additive concentration. · In principle this seems to be the best option in order to manufacture pultruded profiles with natural fibres and bio-resins. The main conclusions drawn from mechanical testing are summarized below: · Furan resins contains different amounts of water which, in conjunction with the water produced during the curing reaction, leads to pultruded profile with high void content and consequently poor mechanical properties. · In general low viscosity furan resins contain more water and lead to more porous composite materials with lower mechanical performance. · Furan resins with lower water content have higher viscosities, which prevent a good impregnation of reinforcing fibres and consequently produce pultruded panels with poor mechanical properties. · The third option is to select furan resins with higher reactivity, but even if this will have a positive effect on pultrusion speed (higher) it would decrease pot life and make it very difficult to work with. Obviously, lower reactivity leads to lower pultrusion speed and longer pot life but from an industrial point of view the process seems not to be economically viable. The BioBuild project entails the design and construction of four case studies, namely: an External Wall Panel (EWP), an External Cladding Kit (EKC), an Internal Partition Kit (IPK) BioBuild Project Deliverable Report 10 CONFIDENTIAL and a Suspended Ceiling Kit (SCK). All systems have been assessed on specific criteria, including fire-safety; dimensional stability; in-service resistance to loads; thermal and acoustic insulation; energy efficiency; and sustainability. The assessment of their performance is the aim of WP6. Aiming to evaluate the mechanical properties of each composite, the tensile and flexural properties of the composites were assessed according to the previously defined test plan; however, some modifications were made to the plan due to the insufficient amount of material that was made available to LNEC in respect to what was requested. All tests were performed at ambient temperature, except in case of the heat deflection temperature (HDT) test. From the results obtained it is possible to conclude the following: · The compression-moulded flax/furan sample shows the best performance and higher mechanical strength, when compared with the other samples tested (lamella sandwich of UP and 0/90º jute fabric on surfaces and cork in the core, and flax/furan on surfaces and thick cork prepreg in the core). · The composite constituted by flax/furan on surfaces and thick cork prepreg in the core, which is designed from sample 3 but adding cork to the core, shows delamination, even before testing. Thus, techniques to modify the surface/interface/interphase should be improved, in order to assure a performance similar or better than the composite without the inner cork layer. Additional work is still being done for a better performance evaluation of the referred composites. More samples are also needed in order to have a complete picture of the mechanical properties of all composites. So far, the initial ignitability tests on the basic performance of the materials showed that: · Furan resin does not ignite easily. · Furan/flax prepregs may ignite and sustain a slow propagation of combustion. · Flax (non-woven) mat is easily ignited and flame spreads very rapidly with total combustion being the final result. · Degradation of the furan surface (cracking, delamination, blistering) exposes the natural fibre reinforcement that will sustain combustion. · On the contrary, Biopol resins ignite (flame edge attack) and sustain the development and propagation of flame resulting in the total combustion of the material. · As expected, if agglomerated cork layers are exposed to flame attack they will ignite (easily if thickness is small) and sustain combustion. · Edges must be protected (in the end product/kit). Practical/cost effective solutions must be studied. · So far, only a RtF class E is guaranteed for most of the different component/material solutions assessed.
Year: 2013
Number Pages:
104p.
Author(s): Pinto, A.; Tjeerdsma, B.; Pina dos Santos, C.; Perremans, D.; Carra, G.; Bermejo, J.; Custódio, J.; Viegas, J.; Patrício, J.; Dzalto, J.; Ribeiro Nunes, L. M.; Real, L. P.; Veras, M.; Rodrigues, M. P.
Editor: LNEC
Keywords: Building construction elements; Biocomposites
Info
Especificação das características de desempenho térmico de janelas, portas e fachadas leves com vidro - Contribuições para o projeto de norma de Seleção de caixilharia em função da sua exposição
No âmbito dos trabalhos da CT 98, que se encontra a preparar o projeto de norma Portuguesa para a especificação das características de desempenho da caixilharia em função da sua exposição, foi efetuada a elaboração do texto preliminar do capítulo sobre as características de desempenho térmico. Neste documento apresenta-se a proposta do LNEC.
Year: 2013
Number Pages:
28pp.
Author(s): Pinto, A.
Editor: LNEC
Info
Consumo de energia do LNEC - Período de 2008 a agosto de 2012
No âmbito da política nacional de eficiência energética (Plano Nacional de Ação para a Eficiência Energética - PNAEE e da Estratégia Nacional para a Energia -ENE2020) o Governo lançou o programa de eficiência energética na administração púbica - ECO-AP, através do qual se visa obter até 2020, nos serviços públicos e nos organismos da administração pública, um nível de eficiência energética na ordem dos 20%, face aos valores de consumo atuais. Neste documento, resume-se a análise das faturas energéticas do LNEC no período de 2008 a agosto de 2012, bem como se apresenta uma estimativa das necessidades de energia primária e das emissões equivalentes de CO2.
Year: 2012
Number Pages:
28pp.
Author(s): Pinto, A.
Editor: LNEC
Info
Centro Comercial Áqua Portimão - Avaliação experimental do desempenho do sistema de ventilação e de controlo de fumo do parque de estacionamento coberto
A empresa Bouygues Imobiliária, SA solicitou ao LNEC um estudo sobre o desempenho do sistema de ventilação e de controlo de fumo do parque de estacionamento coberto do Centro Comercial Áqua Portimão. Este estudo destina-se a verificar se o sistema de ventilação e de controlo de fumo proposto tem possibilidade de satisfazer às necessidades de segurança contra incêndio num empreendimento deste tipo. O sistema de ventilação baseia-se na utilização inovadora de ventiladores de impulso, suspensos no tecto do parque de estacionamento, para promover o escoamento do fumo para a periferia deste, onde é realizada a sua exaustão para o exterior através de ventiladores axiais. Este relatório refere as conclusões da avaliação experimental do desempenho do sistema de ventilação e de controlo de fumo de todo o parque de estacionamento.
Year: 2011
Number Pages:
60pp.
Author(s): Teixeira da Cruz, H.; Viegas, J.
Editor: LNEC
Info
Marcação CE de portas e janelas no âmbito da norma EN 14351-1 - Resultados do inquérito de 2011
Com o objetivo de avaliar o estado de implementação da marcação CE em Portugal e o impacto que teve neste sector de atividade, bem como para identificar as principais características dos produtos colocados no mercado, foi realizado um inquérito on-line a detentores de sistemas e a fabricantes de janelas. Obtiveram-se cinquenta e três respostas. Neste documento apresenta-se o inquérito, os principais resultados e as conclusões do mesmo. Agradece-se às associações ANFAJE1 e AIMMAp2 a colaboração na distribuição do inquérito.
Year: 2011
Number Pages:
32.
Author(s): Pinto, A.
Editor: LNEC
Info
Aspectos metodológico, técnico e sustentável da água de uso urbano - Relatório de actividades de Pós-Doutoramento
O presente relatório descreve a síntese do conjunto de actividades realizadas no âmbito do pós-doutoramento de Douglas Barreto realizado no Núcleo de Acústica, Iluminação, Componentes e Instalações - NAICI do DED no período compreendido entre 5 de outubro de 2009 a 9 de abril de 2010.
Year: 2010
Number Pages:
68pp.
Author(s): Barreto, D.
Editor: LNEC
Info
Fracções habitacionais do empreendimento Estoril Sol Residence - Certificado LNEC da qualidade do processo de instalação das janelas exteriores
N/A
Year: 2010
Number Pages:
27pp.
Author(s): Santos, M. A.
Editor: LNEC
|
ICT
Info
A iluminação natural nos edifícios - Uma perspetiva no âmbito do conforto ambiental e da eficiência energética
A iluminação natural é inquestionavelmente um dos aspetos fundamentais do conforto ambiental nosedifícios e também um dos aspetos que mais pode contribuir para a sua eficiência energética, desde que seja adequadamente captada e distribuída para os espaços interiores. Adicionalmente, têm vindo a ser demonstrados vários benefícios suplementares que o uso da luz natural possui na saúde e bem-estar dos indivíduos, benefícios estes que não são habitualmente tidos em consideração em abordagens mais tradicionais do uso da iluminação natural nos edifícios. Pretende-se com o presente documento efetuar uma introdução aos temas da iluminação natural nos edifícios numa perspetiva holística tendo como pressuposto fundamental a satisfação do conforto dos ocupantes e a utilização racional da energia nos edifícios.
Year: 2014
Author(s): Santos, A. J.
Keywords: Física e tecnologia das construções; Sustentabilidade; Eficiência energética; Conforto visual; Iluminação em edifícios; Iluminação natural
Info
Janelas e portas pedonais exteriores - Guia para a marcação CE (EN 14351-1:2006+A1:2010)
Neste documento apresentam-se os principais aspectos a considerar para a marcação CE da caixilharia exterior (EN 14351-1:2006+A1:2010) a que se aplica o sistema 3 de avaliação da conformidade. São apresentadas as regras gerais necessárias para a avaliação da conformidade. Indicam-se, nomeadamente, os princípios para a selecção de protótipos a submeter aos ensaios de tipo iniciais (ITT), as formas de racionalizar o número de amostras a submeter a ensaio e as recomendações sobre princípios mínimos de controlo interno da produção em fábrica. Complementa-se esta informação com algumas instruções de fabrico e de instalação da caixilharia em obra, de modo a permitir que as janelas e portas instaladas em obra tenham um desempenho conforme com as características declaradas.
Year: 2010
Number Pages:
93pp.
Author(s): Pinto, A.; Fernandes, O.
Editor: LNEC
Keywords: Europa; Guia; Avaliação; Marca de conformidade; Caixilharia; Porta exterior; Janela
Info
COMPONENTES DE EDIFÍCIOS - Selecção de caixilharia e seu dimensionamento mecânico
No presente documento é apresentada a metodologia de dimensionamento mecânico da caixilharia exterior, tendo por base o Regulamento de Segurança e Acções para Estruturas de Edifícios e Pontes [1], e, no quadro das novas normas europeias, a selecção da caixilharia em função da sua exposição nos aspectos de permeabilidade ao ar, estanquidade à água e de resistência às solicitações do vento. Para além disso, é também especificada a selecção das exigências funcionais de caixilharia relativamente aos aspectos de força de manobra, resistência e durabilidade mecânicas.
Year: 2009
Number Pages:
79pp.
Author(s): Viegas, J.
Editor: LNEC
Keywords: Ensaio não destrutivo; Exigência funcional; Ensaio dinâmico; Ensaio de estanquidade; Ensaio de permeabilidade; Caixilharia; Componentes de edifício; Ensaio mecânico
Info
Instalações elevatórias e sobrepressoras de água para edifícios
No presente documento é feita a apresentação de um conjunto de regras de dimensionamento e concepção das instalações elevatórias e sobrepressoras de água para edifícios. Para cada um dos tipos de instalação elevatória ou sobrepressora referidas, procede-se à apresentação de um pequeno exemplo prático de aplicação, de modo a facilitar a compreensão das regras de dimensionamento apresentadas.
Year: 2009
Number Pages:
70pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Drenagem de águas residuais; Instalação sanitária; Instalação de bombagem; Instalação de edifícios; Rede de drenagem de efluentes; Rede de distribuição de água
Info
Medidas para um uso mais eficiente da água nos edifícios
O crescente aumento dos níveis de consumo de água potável em meio urbano, associado a uma cada vez maior escassez dos recursos existentes, quer em termos quantitativos, quer qualitativos, com o consequente aumento do custo da produção para a sua obtenção, deve levar-nos à adopção de medidas que revertam esta tendência. Com o presente documento pretende-se proceder à apresentação de um conjunto de medidas que conduzem a um uso mais eficiente da água nos edifícios, sem que no entanto sejam postos em causa, quer o desempenho funcional adequado dos equipamentos, quer os níveis de conforto e de saúde pública a proporcionar aos consumidores.
Year: 2009
Number Pages:
39pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Instalação sanitária; Instalação de abastecimento de águas; Instalação de edifício; Utilização da água; Área urbana; Água potável; Consumo de água
Info
Isolamento sonoro a sons aéreos e de percussão - Metodologias de caracterização
Este documento apresenta uma síntese das metodologias disponíveis para caracterização do isolamento sonoro dos elementos de compartimentação dos edifícios, tanto a sons aéreos como a sons de percussão. Nesse sentido, faz-se referência a parte do articulado constante da regulamentação em vigor em Portugal Regulamento dos Requisitos Acústicos dos Edifícios , apresentando-se, ao mesmo tempo, o procedimento integrante da norma internacional aplicável para caracterização do comportamento dos elementos em causa, numa perspectiva de valor único (índice). Complementarmente, apresentam-se algumas noções teóricas de base, visando uma melhor integração na formulação e nos conceitos utilizados, fazendo-se também algumas referências a aspectos construtivos e dando-se possíveis pistas para aprofundamento e desenvolvimento de novas metodologias de caracterização do comportamento acústico em questão.
Year: 2008
Number Pages:
67pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Protecção contra o ruído; Ruído de impacto; Ruído aéreo; Acústica de edifícios; Isolamento acústico
|
|
Outro
Info
BioBuild. D6.4 definitive testing of full-scale demonstration installation test-rigs.
The aim of the BioBuild project is to use biocomposite materials to reduce significantly the embodiedenergy in building facade, supporting structure and internal partition systems, with no increase in cost.This will lead to a step change in the use of sustainable, low carbon construction materials, byreplacing aluminium, steel, conventional FRP materials derived from non-renewable resources (suchas GRP), brick and concrete in new-build and refurbished structures.The result expected for the project is a low cost, lightweight, durable and sustainable biocompositebuilding system, based on panels, profiles, frames and sandwich structures, with full technical andenvironmental validation, which offers low embodied energy for different construction products andkits.Under Work Package 1 of the project, Performance and Standards Requirements, the availablematerials were analysed for basic mechanical performance, environmental impact and compatibility.The appropriate standards and legislation were gathered. These were combined and targets set forperformance, resulting in case study specifications. The results of these tasks were reported in thedeliverables
Year: 2015
Author(s): Tjeerdsma, B.; Pina dos Santos, C.; Pereira, J.; Custódio, J.; Viegas, J.; Grandão Lopes, J.; Patrício, J.; Saporiti Machado, J.; Lina Nunes; Real, L. P.; Rodrigues, M. P.; Domingues, M.; Pontífice, P
Keywords: Testing; Building construction elements; Biocomposites
Info
Acousticork T61
N/A
Year: 2011
Number Pages:
6pp.
Author(s): DED/NAICI
Editor: LNEC
Keywords: Europa; Certificação; Isolamento acústico; Aglomerado de cortiça
Info
Provas de Agregação: Programa de Disciplina
N/A
Year: 2006
Author(s): Patricio, J.
Keywords: Conforto; Acústica; Edificios
|