Papers
Info
Numerical evaluation of ventilation perfomance in children day care centres
Modelling of ventilation is strongly dependent on the physical characteristics of the building ofwhich precise evaluation is a complex and time consuming task. In the frame of a research project,two children day care centres (CDCC) have been selected in order to measure the envelope airpermeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature.The data obtained was used as input to the computer code CONTAM for ventilation simulations.The results obtained were compared with direct measurements of ventilation flow from shortterm measurements with CO2 tracer gas and medium term measurements with perfluorocarbontracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affectventilation, the model was used to predict the ventilation rates for a wide range of conditions. Thepurpose of this assessment was to find the best practices to improve natural ventilation. A simpleanalytical method to predict the ventilation flow rate of rooms is also presented. The method isbased on the estimation of wind effect on the room through the evaluation of an average factor (2 (
Year: 2014
Number Pages:
21pp - 189-209pp.
Author(s): Viegas, J.; Nogueira, S .; Aelenei, D.; Teixeira da Cruz, H.; Cano, M.; Neuparth, N.
: Build Simul - n.º 8 de 2015
Editor: Build Simul
Keywords: Pft; Tracer gas; Air permeability; Children day care centre
Info
Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell
This paper presents a thermal simulation validation study of the typical precision that a trained thermal simulation engineer can expect to obtain for the simulation of a room connected to a naturally ventilated double skin facade. The open source building thermal simulation tool EnergyPlus is used to predict air and surface temperatures in a free running weather exposed test cell. The validation approach used does not allow for fine tuning the simulation model by trial and error and includes a sensitivity analysis on the impact of different simulation options such as: number of thermal zones, ground heat transfer and accuracy of solar radiation data. The analysis of the results is consistent with the engineering application goal by focusing on standard indicators: average error, bias and difference between predicted and measured daily maximums. The results show good agreement between simulation and experiment, with an average simulation error in air and radiant temperature of1.4"C and an average daily maximum error of 2.5oC,
Year: 2014
Number Pages:
511-522pp.
Author(s): Mateus, N.; Pinto, A.; Graça, G.
: Energy and Buildings
Editor: Elsevier
Volume:
75.
Keywords: Passive house; Natural ventilation; Energyplus; Double skin façade; Validation; Thermal simulation
Info
Ventilação e qualidade do ar interior em edifícios de comércio e serviços. A estratégia do novo enquadramento regulamentar.
Faz cerca de um ano que publicamos um texto sobre os princípios da ventilação e da qualidade do ar nas habitações. Neste texto apresenta-se um resumo sobre o enquadramento regulamentar da ventilação nos edifícios de comércio e serviços, que segue os princípios de: i) prevenção das emissões, ii) extrações locais quando aplicável e hierarquia de pressões para evitar a dispersão de poluentes, iii) remoção dos poluentes pela renovação do ar. 0 princípio da prevenção das emissões encontra-se consubstanciado por legislação diversa, nomeadamente pela lei do tabaco, dos aparelhos de combustão e do regulamento dos produtos da construção. Foi mantido o incentivo para a utilização de materiais de construção com baixas emissões para o ar interior. Para limitar problemas de qualidade do ar interior, nesta versão do regulamento foi introduzida a necessidade de extração mecânica de ar em locais com fortes odores ou de geração de vapor de água, nomeadamente nas instalações sanitárias. Encontra-se preconizado o princípio de uma hierarquia de pressões dos espaços, através de exaustão de ar nos locais mais poluídos.
Year: 2014
Number Pages:
24pp.
Author(s): Pinto, A.
: Edifícios e Energia
Editor: Média Line, Lda.
Volume:
Publicação Bimestral - N.º 91.
Keywords: Qualidade do ar interior; Ventilação
Info
A Method for the Dynamic Characterisation of Daylighting in Mediterranean Climates
The traditional daylighting calculation methods and the metrics used for its quantification have some limitations. For example, these methods do not take into account, effectively and realistically, the consequences of the dynamic characteristics of natural light and in particular those associated with its energy-related impacts and with the influence of the occupants of the buildings in the final daylighting performance. In view of that, an integrated method for characterization and realistic prediction of the dynamic performance of daylighting was developed. The new method takes into account: i) the characteristics of the luminous climate in the southern European regions, where non-overcast sky conditions prevail; ii) the guarantee of an adequate indoor visual environment and minimization of visual discomfort; iii) the energy-related impacts of daylighting; iv) the influence of environmental management systems and their control strategies in the final daylighting conditions and energy use; and, v) the expectations, preferences, attitudes and behaviours of individuals towards their indoor environmental conditions and control systems at their disposal.
Year: 2013
Number Pages:
2p.
Author(s): Santos, A. J.
: ENBRI Webzine July 2013
Editor: ENBRI - European Network of Building Research Institutes
Keywords: Visual comfort; Energy efficiency; Daylighting
Info
Conservação de energia em edifícios
Os produtos da construção são integrados num "todo" que é o edifício.Todos os produtos nele integrados contribuem para os impactes inerentes ao ciclo de vida do edifício. Na verdade, o princípio que deve ser seguido é o da minimização dos impactes inerentes ao edifício durante todo o ciclo de vida. Naturalmente podem existir alguns aspectos que circunstancialmente sejam considerados mais relevantes e privilegiados. Por exemplo, a energia pode ter uma importância especial pelo grande impacte na fase de utilização do edifício e por ser relevante reduzir a dependência energética a fontes politicamente instáveis, embora este último aspecto tenha a sua importância actual um pouco mais mitigada devido à importante incorporação de energias renováveis de origem nacional no mix energético nacional.
Year: 2013
Number Pages:
16-17pp.
Author(s): Viegas, J.
: Edifícios e Energia
Editor: Media Line, Lda.
Volume:
n.º 85.
Keywords: Custos; Impactes ambientais; Consumo energético
Info
Solar and visible optical properties of glazing systems with venetian blinds: Numerical, experimental and blind control study
The increasing use of glazed areas in the building envelope can lead to high solar gains and glare problems that can strongly impact the entire building energy consumption, peak loads and indoor comfort. An important and fundamental strategy in sustainable building design for controlling solar heat gains and daylighting through fenestration is the use of shading devices. Therefore, it is recommended to use detailed models that can accurately estimate the optical properties of the different types of shading devices (such as roller blinds and venetian blinds) and include their effects in the glazing system analysis. This paper describes a net radiation method for determining both solar and visible optical properties of glazing with shading devices, particularly venetian blinds. Some numerical results were compared with in situ experimental measurements carried out in an outdoor test cell. The experimental work included the measurement of illuminance and irradiance fluxes and the determination of the visible and solar transmission properties of the fenestration system. The agreement between numerical predictions and experimental results was better for overcast than clear sky conditions. Moreover, a venetian blind control strategy that blocks direct solar radiation, whilst enabling the transmission of diffuse radiation to indoors, is implemented.
Year: 2013
Number Pages:
13.
Author(s): Gomes, M.; Santos, A. J.; Rodrigues, A.
: Building and Environment
Editor: Elsevier
Volume:
71 (2014) 47-59.
Keywords: Shading control and solar charts; In-situ experiments; Venetian blind; Multilayer glazing/shading systems; Net radiation method; Solar and visible optical properties
Info
The influence of ventilation systems on domestic gas appliances: An experimental study
Ventilation systems play an important role in the energy consumption of heating and cooling, defining hygrothermal conditions and air quality of dwellings. Among other functions, they are absolutely necessary to ensure oxygen levels needed for household combustion appliances. In Portugal in multifamily housing and with natural ventilation systems, installing a mechanical exhaust fan in every kitchen (decentralized ventilation) is common. In this paper, the impact of such a device is evaluated regarding the performance of a water heating appliance for heating the indoor environment or for domestic hot water (B-type gas appliance usually installed in the kitchen). The combination of natural or mechanical ventilation in the kitchen with the natural exhaust of the gas appliances combustion products were tested as well as the evaluation of critical conditions that lead to stopping the gas appliance safely or to reversing the combustion products in the respective exhaust duct. One of the main conclusions to be drawn is that in the case of mechanical exhaust in the kitchen simultaneously with the natural exhaust of the gas appliances combustion products, the kitchens exterior air inlet is a key device for ensuring proper exhaust of combustion products. In extreme situations, reduced air intake by other means or high extraction flows, they can prevent safely stopping the appliance or even reversing the flow of the combustion products. For this purpose, the maximum flow of mechanical exhaust should also be limited.
Year: 2013
Number Pages:
13p.
Author(s): Pinto, M.; Viegas, J.
: Building and Environment
Editor: ELSEVIER
Volume:
69.
Keywords: Reverse flow; Ventilation systems; Dwellings; Gas appliances; Air permeability
Info
Ventilação de edifícios de habitação: Qualidade do ar interior e eficiência energética
Princípios gerais da proposta para a revisão do RCCTE
Year: 2013
Number Pages:
68-75pp.
Author(s): Pinto, A.
: Edifícios e Energia
Editor: Media Line, Lda.
Volume:
n.º 85.
Keywords: Eficiência energética; Qualidade do ar interior; Edifícios de habitação; Ventilação
Info
Ecodesign - Enquadramento geral e aplicação à climatização
O Ecodesign formaliza uma lógica de desenvolvimento, conceção e utlização dos produtos e serviços baseada nos princípios da análise do ciclo de vida, que permita identificar os aspetos ambientais críticos e com isso icentivar a melhoria contínua dos produtos, mantendo a satisfação dos requisitos funcionais e expetativas dos utilizadores finais,sem implicar: um acréscimo de custo excessivo, redução de segurança, impacto na saúde e a livre circulação de produtos. Existe a preocupação de se agir sobre os produtos mais relevantes e de se agir na fase de conceção do produto, já que é aí que a poluição originada no seu ciclo de vida é determinada e que a maior parte dos custos surgem.
Year: 2012
Number Pages:
70-74pp.
Author(s): Pinto, A.
: Climatização. Edifícios e Energia
Editor: Media Line
Volume:
Publicação Bimestral - N.º 84 - novembro/dezembro.
Keywords: Climatização; Eficiência energética
Info
Integração de aspetos qualitativos na avaliação do ambiente sonoro em zonas urbanas
Para a avaliação da perceção de medidas de minimização de ruído de tráfego rodoviário, em zonas urbanas, foram desenvolvidos no presente trabalho, dois inquéritos, um para avaliação da estrutura cognitiva dos indivíduos ao ruído de tráfego e o outro relativo à perceção das medidas de minimização de ruído. A estrutura e formulação das questões e o seu conteúdo foram baseados na pesquisa bibliografia efetuada, e em entrevistas semiestruturadas previamente realizadas. Para a sua efetivação, foi necessária uma abordagem multidisciplinar, na medida em que se utilizou conhecimentos de psicologia ambiental, estatística, acústica e de psicoacústica.
Year: 2012
Number Pages:
3-6pp.
Author(s): Antunes, S.
: Revista de Acústica
Editor: Sociedade Espanhola de Acústica
Volume:
Vol. 43 / N.os 3 e 4.
Keywords: Ruído de tráfego rodoviário; Mitigação de ruído
|
Comunicação
Info
Avaliação experimental da permeabilidade ao ar da envolvente e do sistema de ventilação. Edifício "Gaioleiro" (1880)
ABSTRACT: This communication presents a set of experimental results and numerical evaluations, characterizing the air permeability and ventilation system of a Gaioleiro building. Regarding the high rates of air infiltration obtained, namely by old wooden windows, it was studied retrofit measures for building airtightness and ventilation system. The results presented in this article show a great potential for building thermal performance improvement, regarding only the retrofit of building airtightness (window improvement or window replacement). In this article its also shown the threat of getting bad ventilation after sealing the building envelope. The air permeability evaluation was determined using the fan pressurization method (EN 13829:2000). The ventilation air flow rate was evaluated with tracer gas concentration decay method (EN ISO 12569:2000). Air flow rates calculation, for current construction and retrofit measures, was carried out using numerical model (EN 15242:2007), validated with the experimental results obtained.
Year: 2011
Number Pages:
8p.
Author(s): Pereira da Silva, F.; Pinto, A.
Editor: LNEC
Keywords: Ensaio; Simulação; Témica; Edifício gaioleiro; Reabilitação; Pressurização; Eficiência energética; Permeabilidade; Ventilação; O a i
Info
Caracterização do escoamento do jacto de ventiladores de impulso
Actualmente não estão ainda definidas regras de projecto da ventilação de impulso aplicada aos parques de estacionamento cobertos. Nesta comunicação são apresentados resultados experimentais que caracterizam o jacto livre axi-simétrico gerado pelos ventiladores de impulso de 50 N e apresenta-se a sua aplicação no dimensionamento da ventilação e do controlo de fumo de parques de estacionamento cobertos sugerido em [1].
Year: 2011
Number Pages:
11p.
Author(s): Teixeira da Cruz, H.; Viegas, J.; Virgílio, A.
Editor: LNEC
Keywords: Jactos; Ventiladores de impulso; Controlo de fumo; Incêndios; Parques de estacionamento
Info
Caracterização experimental do desempenho térmico na estação de aquecimento de um edifício gaioleiro
The energy conservation in buildings is one of the European Union main targets for 2020 to reduce energy dependence and greenhouse gases emissions. For residential buildings, the energy conservations measures are encouraged by several laws, and the thermal performance of building is regulated mainly by RCCTE. Old buildings use substantially different materials and construction solutions from those ones in new constructions, which require special studies to characterize their thermal performance and support the proper evaluation of retrofit measures. The Pombalinos and Gaioleiros buildings are widely studied from the structural and architectural point of view, with little information about their thermal characteristics. This communication presents the experimental results related to the evaluation of thermal performance characteristics in heating mode of a Gaioleiro building located in Lisbon.
Year: 2011
Number Pages:
8p.
Author(s): Mamede, M.; Pinto, A.
Editor: LNEC
Keywords: Ensaio; Simulação; Térmica; Edifício gaioleiro; Reabilitação; Fluximetro; Coeficiente transmissão térmica; Isolamento térmico; Eficiência energética
Info
Cognitive structure of individuals regarding road traffic noise: considerations about their application in global noise impact assessments
In this paper the evaluation of the cognitive structure of individuals in relation to sources of traffic noise was made by using the semantic differential technique applied to people living in urban areas. Audio recordings of the traffic noise were used as objects. 12 sample sounds were selected, and an analysis in terms of physical and psychoacoustic quantities was made. Subsequently, a principal component analysis was made in order to extract the common factors underlying the 21 pairs of considered adjectives. This analysis was conducted jointly for the 12 samples sounds and, individually, for the sounds due to road traffic, vehicle pass by, rail traffic, and air traffic. Then an association between the adjectives pairs and physical and psychoacoustical aspects was done. In the context of the results of this study, some considerations about the parameters used to quantify the impact of noise in urban areas, and the procedures to globally improve public participation in noise impact assessment are made.
Year: 2011
Number Pages:
8p.
Author(s): Antunes, S.; Patrício, J.; Samagaio, A.
Editor: LNEC
Keywords: Perception; Environmental acoustics; Evaluation; Road traffic noise
Info
Controlo de fumo em átrios de grande altura
A maioria das vítimas mortais resultantes de situação de incêndio são atribuídas à inalação de fumo em detrimento das queimaduras. Para além disso, a redução de visibilidade devida ao fumo constitui o maior perigo nos incêndios em átrios e pátios interiores cobertos, pelo que deve constituir um dos aspectos a ter em conta na instalação de controlo de fumo a adoptar. É pois fundamental que o projectista de segurança contra incêndio possa clarificar a natureza do escoamento do fumo no átrio. Pretende-se com este artigo apresentar as abordagens possíveis recorrendo-se à modelação numérica pela utilização de CFD e à modelação física pela utilização de água salgada em modelo reduzido, à escala, do átrio objecto de estudo.
Year: 2011
Number Pages:
12p.
Author(s): Fernandes, C.; Viegas, J.
Editor: LNEC
Keywords: Modelação em água salgada; Cfd; Átrios; Desenfumagem
Info
Especificação da caixilharia no PRONIC
O caderno de encargos técnico, a par do projecto de execução, constitui um elemento fundamental para a definição da obra e dos elementos e componentes que a integram. O ProNIC (Protocolo para a Normalização da Informação Técnica na Construção), numa das suas várias vertentes, permite a constituição do caderno de encargos da obra através de uma ferramenta informática. Nesta comunicação apresenta-se genericamente a forma como foi concebida esta ferramenta, no âmbito da caixilharia, analisando-se detalhadamente as vantagens e desvantagens na sua adopção, e os aspectos práticos que resultaram da sua aplicação à terceira fase das obras de reabilitação das escolas secundárias promovidas pela Parque Escolar.
Year: 2011
Number Pages:
8p.
Author(s): Viegas, J.; Couto, P.; Gonçalves, M.
Editor: LNEC
Keywords: Pronic; Especificação do desempenho; Caixilharia
Info
Integração da avaliação da percepção de medidas de minimização para o ruído de tráfego rodoviário, em estudos de impacte ambiental
This paper presents a summary of psychoacoustics tests made in order to assess the perception of noise mitigation measures. Question were addressed in order to understand the sound perception, the visual assessment of noise barriers from photographs, and the degree of pleasantness and corresponding effectiveness of picture and sound from behind noise barriers. Comparison between sounds of a vehicle passage in different pavements and the association between the physical and perceptual data are also presented. The results suggest the importance of public information about the noise mitigation measures and the integration of public perceptions in noise impact studies. Advantage of computer technology can be taken for the presenting information to the public (including sound recordings) in order to assess to the perception and information about the visual noise barriers.
Year: 2011
Number Pages:
8p.
Author(s): Antunes, S.; Patrício, J.; Samagaio, A.
Editor: LNEC
Keywords: Impacte ambiental; Rodoviário; Ruído tráfego; Medidas de minimização
Info
Modelação Física de Incêndios Confinados
Nesta comunicação apresenta-se o formalismo em que se baseia a modelação física de incêndios. É particularizada a modelação em escala real mas com velocidade reduzida, que possibilita a realização de ensaios com fontes de calor menos intensas do que as previstas em projecto, e a modelação em escala reduzida fazendo uso da analogia de água salgada. Evidencia-se a sua adequação e necessidade de utilização em alguns casos, mesmo quando se compara com a utilização de modelos numéricos.
Year: 2011
Number Pages:
12p.
Author(s): Viegas, J.
Editor: LNEC
Keywords: Modelação em água salgada; Ensaios; Modelação física; Incêndios confinados
Info
O controlo de fumo em caixas de palco
Nesta comunicação apresentam-se os resultados de um estudo da aplicação de sistemas de controlo de fumo ao interior da caixa de palco de um teatro. Foram realizadas simulações computacionais com o programa Fire Dynamic Simulator.. Paralelamente procedeu-se também à modelação física recorrendo à técnica de água salgada, que permite a utilização de modelos em escala reduzida. São analisados os resultados das simulações computacionais e comparados com os resultados do modelo à escala reduzida.
Year: 2011
Number Pages:
11p.
Author(s): Valadares, R.; Viegas, J.; Rodrigues, J. P.
Editor: LNEC
Keywords: Modelação em água salgada; Cfd; Caixas de palco; Controlo de fumo
Info
Rational use of potable water and potential use of rainwater and reclaimed water in residential buildings
This paper presents the results of a survey on domestic water consumption inside buildings covering some countries in European and American continents, namely Portugal, United States of America USA and Brazil.. Some studies were identified and in which one was found the percentage of waterconsumed in the various activities carried out within the buildings, either by simple activities performed by residents, as well by appliances that add up the heaviest services automatically (dish and clothes washers). Considering the residential water profiles it was identified which part could be supplied by rainwater and the essential part exclusively supplied with drinking water. From this perspective was performed some calculations to find out the water savings by using rainwater for domestic purposes and which appliances inside buildings are eligible to be supplied. As complementary and considering that waste water generated by some appliances (showers) it was performed the calculations including the wastewater reclaimed inside buildings. The study finds out an average of drinkable water savings of 28 to 100 % for WC cisterns using rainwater and reclaimed water. Some other savings are presented according to sanitary appliance and inside or outside house activities when rain and reclaimed water were used. In conclusion it is noted that for the first part of residential water consumption there is a range of possibilities to promote the rational use of water by adopting measures involving design, saving water equipment and educational campaigns. For the second part it was highlighted the use of rainwater as an alternative.
Year: 2011
Number Pages:
15p.
Author(s): Barreto, D.; Pedroso, V.
Editor: Civil Enginneering Department of Sao Carlos Ferderal University - Brazil
Keywords: Reclaimed water; Rainwater use; Water consumption; Rational use of water
|
Books
Info
Weathering of Polymers and Plastic Materials
This book presents the state of the art on the weathering of polymers and plastic materials in outdoor applications, comprising natural weathering, accelerated climatic weathering, laboratory artificial accelerated weathering, and lifetime prediction methodology. It summarizes the most suitable methods of instrumental analysis to access and quantify (when possible) degradation caused by weathering, while also covering the degradation and stabilization of polymers based on environmental and artificially induced factors. Innovative polymer additives and some developments in polymeric materials designed for outdoor applications are also included, emphasizing a few selected cases. the book intends to be an important reference source for those involved in the study of the durability of polymers and plastics, production of plastics for exterior applications, chemists responsible for quality control of plastic products, and researchers and students across plastics engineering, polymer science, polymer chemistry and environmental science.
Year: 2023
Number Pages:
XXIV, 136.
Author(s): Real, L. P.
: Weathering of Polymers and Plastic Materials
Editor: SPRINGER NATURE
Keywords: Lifetime prediction; Correlation; Durability; Polymer degradation; Polymer stabilization; Plastics; Artificial weathering; Climatic weathering
Info
Recycled Materials for Construction Applications - Plastic Products and Composites.
In this work, a general approach to the recyclability of plastics and composites used in construction, with the purpose of their reuse, is made.The various recycling technologies applicable to the plastic materials, most used in construction, and their various stages are described, detailing for the main polymers, and indicating the difficulties inherent in these processes. In this context, several Illustrative cases of success and examples of recent technological innovation are presented.It also addresses the issue of quality control, certification, and standardization adopted in Europe for recycled plastics.Some market data are presented, namely the production capacity, data for bio-based plastics and polymers, the quantities of recycled plastic and, for each type of polymer, statistics data on recycling and market barriers of recycled materials, also referring to the variables that most influence recycling costs and the price of recycled materials.The conclusions drawn from this work are of several types. In a succinct way, they demonstrate that recycling is a fundamental resource to minimize waste and reduce environmental pollution, constituting a strategic approach to the management of waste from plastic construction products at the end of its useful life.The main challenges and future perspectives that arise from the most recent developments in this area are made.Finally, the most relevant strategic recommendations are presented in order to continue and concretize the resolution of the problem of recycling plastics and seek to achieve the objectives of the circular economy, which involves the development of the specialized market for recycling and recycled plastics and, consequently, promote the purchase and sale operations of economic agents and interested parties (sellers, buyers, consumers, associations, recyclers, manufacturers of production machinery, etc.) in order to also increase the recycling and recyclability of plastic waste.
Year: 2022
Number Pages:
1-162.
Author(s): Real, L. P.
: Recycled Materials for Construction Applications - Plastic Products and Composites.
Editor: Springer
Keywords: Environmental impact; Recycling; Circular economy; Construction; Sustainability; Composites; Plastics
Info
Método LNEC para avaliação e classificação da qualidade acústica de edifícios habitacionais
Esta publicação apresenta uma metodologia para avaliar a qualidade acústica de edifícios habitacionais, ou partes deles (fogos), visando a sua qualificação em termos das características da componente acústica interior, nos espaços com utilização sensível, contribuindo, consequentemente, para a sustentabilidade ambiental e para o reforço dos padrões de qualidade de vida do cidadão. A metodologia proposta assenta num processo de avaliação segundo três linhas estratégicas fundamentais, às quais corresponde um determinado nível físico, respetivamente: uma relacionada com a integração da unidade edificada no seu ambiente próximo (ou seja, tendo em conta um contexto de planeamento), designada na presente publicação por Vizinhança; outra relacionada com a disposição interior dos diversos espaços funcionais e com a sua inter-relação cruzada, assim como com os diferentes usos que podem estar associados às diversas frações autónomas existentes (ex. fogos versus espaços comerciais), para além das caraterísticas acústicas dos espaços comuns, a qual é intitulada Edifício; e uma outra assente na eficácia acústica das soluções de compartimentação adotadas e no nível máximo admissível do ruído de equipamentos de uso coletivo, designada por Habitação. Por último, apresentam-se, a título de exemplo, algumas casos práticos que possibilitam demonstrar a potencialidade, as nuances, e o interesse de que se pode revestir o uso da metodologia em causa para classificação, e eventual etiquetagem, da qualidade acústica das unidades habitacionais, potenciando assim a qualidade correspondente e introduzindo um novo parâmetro de valoração de mercado.
Year: 2013
Number Pages:
77pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Conforto acústico; Avaliação; Controle de qualidade; Edifício de habitação; Acústica de edifício
Info
IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia
A IV Conferência Nacional em Mecânica de Fluidos, Termodinâmica e Energia (MEFTE 2012) contempla diversas áreas temáticas onde métodos experimentais, analíticos e numéricos contribuem para o progresso nestas áreas científicas. Esta conferência é uma organização conjunta entre o Laboratório Nacional de Engenharia Civil (LNEC), a Universidade Nova de Lisboa (UNL), o Instituto Superior de Engenharia de Lisboa (ISEL), o Instituto Superior Técnico (IST), a Faculdade de Engenharia da Universidade do Porto (FEUP) e a Universidade de Coimbra (UC), sob os auspícios da Associação Portuguesa de Mecânica Teórica, Aplicada e Computacional (APMTAC). A APMTAC promove bienalmente esta conferência nacional temática, como um dos seus objectivos estratégicos e estatutários, no âmbito da mecânica dos fluidos, termodinâmica e energia. Na sequência do sucesso das conferências anteriores (2006 FCT-UNL, 2008 U. Aveiro, 2009 Instituto Politécnico de Bragança), a IV Conferência Nacional é realizada nas instalações do Laboratório Nacional de Engenharia Civil, nos dias 28 e 29 de Maio de 2012. Foram inicialmente submetidos 111 resumos de investigadores portugueses e estrangeiros, dos quais resultaram 80 comunicações que foram submetidas a avaliação. A Comissão Organizadora manifesta o seu apreço e agradece a todos os que contribuiram para a realização deste evento, em especial, aos membros das Comissões Científica e Executiva pelo seu esforço e dedicação, assim como a todos os autores e participantes. Agradecemos ainda aos oradores convidados para as sessões plenárias pelo seu contributo em tornar esta conferência um lugar de partilha de conhecimentos do estado da arte da mecânica de fluidos, termodinâmica e energia. Finalmente agradecemos aos nossos patrocinadores o seu apoio à realização desta conferência.
Year: 2012
Number Pages:
192pp.
Author(s): entidade LNEC
Editor: LNEC
Keywords: Congresso; Energia; Termodinâmica; Mecânica dos fluidos; Pt
Info
Road Tunnels: Operational strategies for emergency ventilation
Le présent document est un rapport préparé par le groupe de travail n° 6 « Ventilation et maîtrise des incendies » du comité technique C3.3 'Exploitation des tunnels routiers' de lAssociation mondiale de la Route (AIPCR). Ce rapport fournit des informations sur lexploitation des systèmes de ventilation des tunnels dans les cas durgence, principalement ceux causés par un incendie. En exploitation normale, la ventilation est nécessaire pour assurer la propreté de lair ambiant et préserver la visibilité dans le tunnel, en évitant laccumulation de gaz polluants et de particules. En cas dincendie, lexploitation de la ventilation doit être modifiée pour passer de son mode normal à un mode qui optimise les possibilités dévacuation des usagers du tunnel et dintervention sûre des services durgence. La stratégie à adopter dépend de la géométrie spécifique du tunnel, de la densité du trafic et de son mode de circulation uni ou bidirectionnel. Après une discussion des travaux antérieurs de lAIPCR et quelques remarques sur la directive européenne de 2004 et les recommandations nationales concernant la ventilation des tunnels, le rapport présente des informations sur les types de système de ventilation communément utilisés, tels que les systèmes longitudinal, transversal et semi-transversal. Les objectifs visés dans lidéal pour la maîtrise des fumées dans ces différents types de tunnel sont ensuite traités, et le mode de commande préféré est présenté. Ceci peut inclure, par exemple, le contrôle de la vitesse du courant dair longitudinal, une fonction qui peut ne pas être disponible dans tous les cas, mais qui devrait normalement être prévue dans un ouvrage nouveau. Les principes de la commande de la ventilation sont alors décrits dans leurs grandes lignes, et quelques remarques sur la maintenance et les essais de vérification suivent.
Year: 2011
Number Pages:
99p.
Author(s): Allemann, M.; Brandt, R.; Carlotti, P.; Viegas, J.
Editor: PIARC
Volume:
2011R02.
Keywords: Controlo de fumo; Ventilação; Túneis
Info
Sistemas de combate a incêndios em edifícios - De acordo com a nova regulamentação
Com o advento da nova regulamentação de segurança contra incêndios em edifícios, e tendo em conta a importância da mesma na segurança das pessoas e bens, pretende-se com este documento colocar à disposição dos projectistas, alunos de engenharia e de todos aqueles que se relacionem de alguma forma com a temática dos sistemas de combate a incêndios com água em edifícios, uma súmula das partes mais relevantes do regulamento, destinadas a este fi m, bem como a apresentação de metodologias de cálculo, adequadas, que facilitem a compreensão e aplicação destas, no sentido da obtenção de projectos que conduzam à produção de sistemas com níveis de desempenho funcional satisfatório.
Year: 2010
Number Pages:
74pp.
Author(s): Pedroso, V.
Editor: LNEC
Volume:
NS 117 Não Seriados.
Keywords: Protecção dos edifícios contra o fogo; Segurança contra incêndios
Info
A acústica nos edifícios. Pavimentos e revestimentos de pavimentos, isolamento a sons de percussão
As exigências relativas às condições acústicas dos edifícios encontram-se definidas no Regulamento dos Requisitos Acústicos dos Edifícios, aprovado pelo Decreto-Lei nº 129/2002 de 11 de Maio, com as alterações introduzidas pelo Decreto-Lei n.º 96/2008 de 9 de Junho. A necessidade de conhecimento das características de isolamento a sons de percussão, de diferentes soluções, na elaboração dos projectos de condicionamento acústico, fundamenta o objectivo desta publicação e é consubstanciado pela compilação de resultados de diferentes soluções obtidos em laboratório. No sentido de contextualizar a informação disponibilizada, referem-se os conceitos gerais, os parâmetros característicos e a terminologia utilizada, assim como as variáveis que condicionam o desempenho dos elementos de separação horizontal à transmissão de sons de percussão. É ainda apresentado um exemplo de estimativa das condições de isolamento a sons de percussão, usando o método simplificado constante da norma EN 12354-2:2000 Building Acoustics Estimation of acoustic performance of buildings from the performance of elements Part 2: Impact sound insulation between rooms.
Year: 2009
Number Pages:
133pp.
Author(s): Domingues, M.
Editor: LNEC
Keywords: Revestimento de pavimento; Pavimento de edifício; Isolamento acústico; Acústica de edifício
Info
Projecto de condicionamento acústico de edifícios
A Acústica apresenta um carácter diagonal no domínio do conhecimento científico, o que pode determinar dificuldades na abordagem de áreas específicas, como seja o domínio do condicionamento acústico de edifícios. Há também a considerar o facto de serem muito reduzidas as potências postas em jogo na audição humana, apesar de este sentido ser muito importante no diálogo do Homem com o Ambiente. Afigurou-se oportuno, face ao quadro esquissado, congregar, de modo ordenado, elementos entendidos como necessários para o desenvolvimento de estudos de engenharia no domínio do condicionamento acústico de edifícios. Não está em causa um pretenso tratado nem um vade-mécum de Acústica aplicada, mas um instrumento com interesse para quem pretenda exercer actividade de Engenharia Acústica, no projecto de condicionamento acústico de edifícios.
Year: 2009
Number Pages:
76pp.
Author(s): Silva, P. M.
Editor: LNEC
Keywords: Nível sonoro; Conforto acústico; Acústica de edifícios
|
|
Tese de Doutoramento
Info
Utilização de ventilação de impulso em parques de estacionamento cobertos
A aplicação da ventilação de impulso em parques de estacionamento cobertos tem conhecido uma grande expansão em Portugal no último decénio. Este tipo de ventilação baseia-se na utilização de um conjunto de ventiladores axiais, suspensos no tecto do parque de estacionamento, que gera um escoamento adequado para promover o varrimento entre a admissão de ar novo e a exaustão, normalmente realizada por ventiladores axiais periféricos, de forma a assegurar o escoamento para o exterior dos poluentes emitidos pelos veículos. Na condição de incêndio este sistema de ventilação é utilizado para limitar o escoamento do fumo no interior do parque de estacionamento coberto e também para promover o seu escoamento para o exterior. Neste documento é feita uma síntese crítica do conhecimento neste domínio utilizando o levantamento do estado do conhecimento nas matérias relevantes para estabelecer recomendações de concepção e de dimensionamento de tais sistemas. Este documento também identifica as necessidades de investigação neste domínio, detalha o conteúdo dos projectos de investigação que devem ser realizados, estabelece as bases da sua coordenação através de um programa de investigação de forma a ser possível criar sinergias e identifica as oportunidades de formação pós-graduada, apoiadas nesse programa de investigação.
Year: 2009
Author(s): Viegas, J.
Info
Aplicação da avaliação de ciclo de vida à análise energética e ambiental de edifícios
O impacto energético e ambiental dos edifícios é cada vez mais importante nas sociedades contemporâneas, pelo consumo de energia e de recursos durante a fase de utilização dos edifícios, mas também pelas fases de construção e demolição. Encontra-se comprovado que os edifícios são responsáveis por cerca de 46% do consumo de energia primária no concelho de Lisboa, mas não se encontra apreciado o impacte da fase de construção e demolição. No âmbito desta tese aplicou-se a metodologia de análise do ciclo de vida a edifícios, desde a fase de construção até à demolição, com o objectivo de avaliar os impactes ambientais directamente relacionados com o edifício, em particular avaliar as possíveis interacções entre a fase de construção e a fase de utilização. Para efectuar a análise do ciclo de vida foram inicialmente definidos os aspectos de conforto ambiental interior a satisfazer. Foram avaliados os impactes ambientais associados ao fabrico e à utilização de alguns materiais de construção e de instalações de edifícios de forma a possibilitar a ACV. Tendo em conta o impacte dos envidraçados nas necessidades energéticas na fase de utilização dos edifícios, foi efectuada a avaliação de diferentes soluções envidraçadas de forma a estabelecer áreas de vidro optimizadas que minimizem as necessidades energéticas de aquecimento, arrefecimento e iluminação. Foi avaliada experimentalmente a permeabilidade ao ar de edifícios Portugueses e foi avaliado o impacte da permeabilidade nas infiltrações de ar e nas necessidades de climatização para diferentes tipos de sistemas de ventilação, sendo apresentada uma proposta de limites a adoptar para os edifícios Portugueses. Por fim a metodologia de ACV do edifício foi aplicada a casos de estudo sendo evidenciado que o impacte ambiental dos edifícios vai para além do consumo de energia na fase de utilização, pois a fase de construção de edifícios novos e de fim-de-vida pode corresponder a sensivelmente 30% do impacte ambiental do edifício. Se for considerado apenas a construção, fase de fim-de-vida e a energia para climatização, o impacte ambiental da construção é de sensivelmente 90% para o caso de Lisboa. Nos casos de estudo foi evidenciado que existe um ponto de optimização do nível de isolamento térmico dos elementos opacos a partir do qual as poupanças de energia associadas ao incremente da espessura do isolante térmico não compensam a carga ambiental nele incorporada. Por outro lado para reduzir o impacte ambiental dos edifícios é evidenciado que a concepção de edifícios que prevejam a reutilização dos elementos de construção mais pesados tem um peso que é cerca do dobro do associado à optimização do isolamento térmico do edifício.
Year: 2008
Author(s): Pinto, A.
Keywords: Qualidade do ambiente interior; Declaração ambiental; Ciclo de vida; Eficiência energética; Edifícios; Sustentabilidade
|
Dissertação de Mestrado
Info
Projecto de desenvolvimento tecnológico de condutas de evacuação de produtos da combustão de turbinas a gás utilizadas para propulsão naval
Nos sistemas de evacuação dos produtos da combustão de turbinas a gás, utilizadas na propulsão naval de alguns navios de combate, tem-se verificado a ocorrência de nucleação e propagação de fissuras através das paredes de pressão do sistema, tendo as principais fissuras propagando-se a partir dos pés dos cordões de soldadura. A conduta do sistema em estudo é constituída num aço inoxidável austenítico, AISI 316L (N), designado pela norma EN 10088-1 por 1.4404, com uma espessura de aproximadamente 3,7 mm. Em estudos anteriores foi medida a temperatura exterior da parede de pressão da conduta, tendo-se registado 350 ºC na zona junto ao anel de suporte inferior. No presente trabalho, e com o intuito de se proceder a uma substituição localizada do material constituinte da conduta, foram realizados estudos metalográficos comparativos entre o aço inoxidável austenítico 1.4404 e o aço inoxidável austenítico 1.4376, tendo-se também efectuado a determinação da composição química dos mesmos. Definiu-se a geometria dos provetes de fadiga e de fluência (e tracção), tendo neste último sido determinado a carga máxima de ensaio e a sua verificação pelo método de elementos finitos. O trabalho foi concluído com a modelação numérica do escoamento do fluido, num programa de diferenças finitas comercial, para a determinação do campo de pressões e temperaturas actuantes na conduta.
Year: 2008
Author(s): Cruz, H.
Keywords: Modelação cfd; Aço inoxidável 1.4376; Aço inoxidável 1.4404; Turbina a gás; Conduta de evacuação dos produtos da combustão
|
Relatório Científico
Info
EMPREENDIMENTO SEIXAL BAÍA 1.ª FASE, LOTES 8, 10, 11 e 12 Certificado LNEC da qualidade do processo de instalação da caixilharia exterior
N/A
Year: 2009
Number Pages:
20pp.
Author(s): Pina dos Santos, C.
Info
Avaliação da eficácia das medidas de minimização de impactes ambientais implementadas em Portugal
O presente relatório foi elaborado para a Estradas de Portugal, S.A. (adiante designada por EP, S.A.) no âmbito do estudo Avaliação da Eficácia das Medidas de Minimização de Impactes Ambientais Implementadas em Portugal, desenvolvido pelo Laboratório Nacional de Engenharia Civil (LNEC) e pela Universidade de Évora. Corresponde ao Relatório Final da componente Ruído. Integra uma compilação de todo o trabalho desenvolvido ao longo do período de vigência do estudo, pelo que incluem as actividades efectuadas e apresentadas em relatórios anteriores, bem como as novas componentes realizadas nos últimos meses e que integram os capítulos 4, 5, 6 e 7. Este relatório foi estruturado nos seguintes sete capítulos: Capítulo 1 Introdução; Capítulo 2 Levantamento e caracterização dos sistemas; Capítulo 3 Avaliação da eficácia de várias medidas de minimização; Capítulo 4 Análise dos resultados de programas de monitorização; Capítulo 5 Breve análise custo-eficácia das medidas de minimização de ruído; Capítulo 6 Proposta de directrizes para a orientação da prática para a implementação de sistemas de minimização de ruído; Capítulo 7 Indicação de programas de monitorização.
Year: 2008
Number Pages:
140pp.
Author(s): Antunes, S.; Patrício, J.
Keywords: Ruído; Implementadas em portugal; Impactes ambientais; Medidas de minimização; Avaliação da eficácia
Info
Proposta de medidas para um uso mais eficiente da água nos edifícios
O crescente aumento dos níveis de consumo de água potável em meio urbano, associado a uma cada vez maior escassez dos recursos existentes, quer em termos quantitativos, quer qualitativos, com o consequente aumento do custo da produção para a sua obtenção, deve levar-nos à adopção de medidas que revertam esta tendência. Com o presente documento pretende-se proceder à apresentação de um conjunto de medidas que conduzem a um uso mais eficiente da água nos edificios, sem que no entanto sejam postos em causa, quer o desempenho funcional adequado dos equipamentos, quer os níveis de conforto e de saúde pública a proporcionar aos consumidores.
Year: 2008
Number Pages:
43pp.
Author(s): Pedroso, V.
Keywords: Meio urbano; Consumo de água
Info
Caixilharia de edifícios - Aspectos de segurança e resistência mecânica do vidro
A aplicação do vidro na construção tem sofrido um desenvolvimento acentuado nos anos mais recentes, com a aplicação de vidros com propriedades reforçadas de isolamento térmico, controlo solar, isolamento sonoro, tendo propiciado a aplicação de envidraçados cada vez de maior dimensão. Neste relatório pretende-se sintetizar os aspectos de segurança a que os vidros devem satisfazer, de forma a minimizar o risco de rotura dos vidros e de ferimentos em pessoas, tendo em conta as normas Europeias publicadas nos anos mais recentes. Nesse âmbito, foi efectuado um estudo detalhado do risco de rotura por choque térmico dos vidros para as condições climáticas de Portugal, no sentido de auxiliar na especificação de vidro de elevada resistência ao choque térmico.
Year: 2007
Number Pages:
70pp.
Author(s): Pinto, A.
|
ICT
Info
A iluminação natural nos edifícios - Uma perspetiva no âmbito do conforto ambiental e da eficiência energética
A iluminação natural é inquestionavelmente um dos aspetos fundamentais do conforto ambiental nosedifícios e também um dos aspetos que mais pode contribuir para a sua eficiência energética, desde que seja adequadamente captada e distribuída para os espaços interiores. Adicionalmente, têm vindo a ser demonstrados vários benefícios suplementares que o uso da luz natural possui na saúde e bem-estar dos indivíduos, benefícios estes que não são habitualmente tidos em consideração em abordagens mais tradicionais do uso da iluminação natural nos edifícios. Pretende-se com o presente documento efetuar uma introdução aos temas da iluminação natural nos edifícios numa perspetiva holística tendo como pressuposto fundamental a satisfação do conforto dos ocupantes e a utilização racional da energia nos edifícios.
Year: 2014
Author(s): Santos, A. J.
Keywords: Física e tecnologia das construções; Sustentabilidade; Eficiência energética; Conforto visual; Iluminação em edifícios; Iluminação natural
Info
Janelas e portas pedonais exteriores - Guia para a marcação CE (EN 14351-1:2006+A1:2010)
Neste documento apresentam-se os principais aspectos a considerar para a marcação CE da caixilharia exterior (EN 14351-1:2006+A1:2010) a que se aplica o sistema 3 de avaliação da conformidade. São apresentadas as regras gerais necessárias para a avaliação da conformidade. Indicam-se, nomeadamente, os princípios para a selecção de protótipos a submeter aos ensaios de tipo iniciais (ITT), as formas de racionalizar o número de amostras a submeter a ensaio e as recomendações sobre princípios mínimos de controlo interno da produção em fábrica. Complementa-se esta informação com algumas instruções de fabrico e de instalação da caixilharia em obra, de modo a permitir que as janelas e portas instaladas em obra tenham um desempenho conforme com as características declaradas.
Year: 2010
Number Pages:
93pp.
Author(s): Pinto, A.; Fernandes, O.
Editor: LNEC
Keywords: Europa; Guia; Avaliação; Marca de conformidade; Caixilharia; Porta exterior; Janela
Info
COMPONENTES DE EDIFÍCIOS - Selecção de caixilharia e seu dimensionamento mecânico
No presente documento é apresentada a metodologia de dimensionamento mecânico da caixilharia exterior, tendo por base o Regulamento de Segurança e Acções para Estruturas de Edifícios e Pontes [1], e, no quadro das novas normas europeias, a selecção da caixilharia em função da sua exposição nos aspectos de permeabilidade ao ar, estanquidade à água e de resistência às solicitações do vento. Para além disso, é também especificada a selecção das exigências funcionais de caixilharia relativamente aos aspectos de força de manobra, resistência e durabilidade mecânicas.
Year: 2009
Number Pages:
79pp.
Author(s): Viegas, J.
Editor: LNEC
Keywords: Ensaio não destrutivo; Exigência funcional; Ensaio dinâmico; Ensaio de estanquidade; Ensaio de permeabilidade; Caixilharia; Componentes de edifício; Ensaio mecânico
Info
Instalações elevatórias e sobrepressoras de água para edifícios
No presente documento é feita a apresentação de um conjunto de regras de dimensionamento e concepção das instalações elevatórias e sobrepressoras de água para edifícios. Para cada um dos tipos de instalação elevatória ou sobrepressora referidas, procede-se à apresentação de um pequeno exemplo prático de aplicação, de modo a facilitar a compreensão das regras de dimensionamento apresentadas.
Year: 2009
Number Pages:
70pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Drenagem de águas residuais; Instalação sanitária; Instalação de bombagem; Instalação de edifícios; Rede de drenagem de efluentes; Rede de distribuição de água
Info
Medidas para um uso mais eficiente da água nos edifícios
O crescente aumento dos níveis de consumo de água potável em meio urbano, associado a uma cada vez maior escassez dos recursos existentes, quer em termos quantitativos, quer qualitativos, com o consequente aumento do custo da produção para a sua obtenção, deve levar-nos à adopção de medidas que revertam esta tendência. Com o presente documento pretende-se proceder à apresentação de um conjunto de medidas que conduzem a um uso mais eficiente da água nos edifícios, sem que no entanto sejam postos em causa, quer o desempenho funcional adequado dos equipamentos, quer os níveis de conforto e de saúde pública a proporcionar aos consumidores.
Year: 2009
Number Pages:
39pp.
Author(s): Pedroso, V.
Editor: LNEC
Keywords: Instalação sanitária; Instalação de abastecimento de águas; Instalação de edifício; Utilização da água; Área urbana; Água potável; Consumo de água
Info
Isolamento sonoro a sons aéreos e de percussão - Metodologias de caracterização
Este documento apresenta uma síntese das metodologias disponíveis para caracterização do isolamento sonoro dos elementos de compartimentação dos edifícios, tanto a sons aéreos como a sons de percussão. Nesse sentido, faz-se referência a parte do articulado constante da regulamentação em vigor em Portugal Regulamento dos Requisitos Acústicos dos Edifícios , apresentando-se, ao mesmo tempo, o procedimento integrante da norma internacional aplicável para caracterização do comportamento dos elementos em causa, numa perspectiva de valor único (índice). Complementarmente, apresentam-se algumas noções teóricas de base, visando uma melhor integração na formulação e nos conceitos utilizados, fazendo-se também algumas referências a aspectos construtivos e dando-se possíveis pistas para aprofundamento e desenvolvimento de novas metodologias de caracterização do comportamento acústico em questão.
Year: 2008
Number Pages:
67pp.
Author(s): Patrício, J.
Editor: LNEC
Keywords: Protecção contra o ruído; Ruído de impacto; Ruído aéreo; Acústica de edifícios; Isolamento acústico
|
|
Outro
Info
BioBuild. D6.4 definitive testing of full-scale demonstration installation test-rigs.
The aim of the BioBuild project is to use biocomposite materials to reduce significantly the embodiedenergy in building facade, supporting structure and internal partition systems, with no increase in cost.This will lead to a step change in the use of sustainable, low carbon construction materials, byreplacing aluminium, steel, conventional FRP materials derived from non-renewable resources (suchas GRP), brick and concrete in new-build and refurbished structures.The result expected for the project is a low cost, lightweight, durable and sustainable biocompositebuilding system, based on panels, profiles, frames and sandwich structures, with full technical andenvironmental validation, which offers low embodied energy for different construction products andkits.Under Work Package 1 of the project, Performance and Standards Requirements, the availablematerials were analysed for basic mechanical performance, environmental impact and compatibility.The appropriate standards and legislation were gathered. These were combined and targets set forperformance, resulting in case study specifications. The results of these tasks were reported in thedeliverables
Year: 2015
Author(s): Tjeerdsma, B.; Pina dos Santos, C.; Pereira, J.; Custódio, J.; Viegas, J.; Grandão Lopes, J.; Patrício, J.; Saporiti Machado, J.; Lina Nunes; Real, L. P.; Rodrigues, M. P.; Domingues, M.; Pontífice, P
Keywords: Testing; Building construction elements; Biocomposites
Info
Acousticork T61
N/A
Year: 2011
Number Pages:
6pp.
Author(s): DED/NAICI
Editor: LNEC
Keywords: Europa; Certificação; Isolamento acústico; Aglomerado de cortiça
Info
Provas de Agregação: Programa de Disciplina
N/A
Year: 2006
Author(s): Patricio, J.
Keywords: Conforto; Acústica; Edificios
|