Papers
Info
Gap inner presure in multy-storey double skin facades
double-skin façades (DSF) areused as an architectural solution to improve indoor comfort being characterized by having at least two membranes between the indoor occupied space and the exterior environment, separated by ana ir gap where the shading devices lie. The pressure within he gap plays an important role on i) the glazing structural safety; ii) te sahft ventilation, in particular if a natural ventilation scheme is implemented, but also to promote an efficient gap air change, and; iii) the safety of the maintenence satff, especially when windows may be opened to the interior.Although there are several DSF typologies only the multi-storey case, where no horizontal or vertical partitioning exists between the two skins, will be analised in this paper. Nevertheless, there are still a number of possible layouts for multi-storey DSF that might impose different pressure distributions within the gap. This paper refers to a set of wind tunnel tests made over a building model wit different multi-storey DSF layouts - from open an all edges to fully lateral closure and from naroow to wide gap depths, for an extented range of wind directions. The experimental data showed a layout dependent inner wall pressure distribution that may be considered different from the unsheltered building.
Year: 2008
Number Pages:
1553-1559.
Author(s): Marques da Silva, F.; MG Gomes
Editor: Elsevier
Volume:
40.
Keywords: Double skin façades
Info
Load Tests of a Cable-Stayed Bridge in Coimbra, Portugal
Field load testing is an effective method to evaluate bridge performance and to calibrate structural models. This paper presents the load tests of the cable-stayed Rainha Santa Isabel Bridge which crosses the Mondego River near Coimbra, in Portugal. During these tests, several parameters were measured, like vertical displacements of the deck, horizontal displacements of the mast, rotations, strains and stay forces. Different types of equipment were used in order to get more accurate measurements. The experimental results are compared with the analytical values computed with a finite element model of the bridge.
Year: 2007
Number Pages:
337-341pp.
Author(s): Oliveira Santos, L.; Xu, Min
: Structural Engineering International
Editor: Taylor & Francis
Volume:
Volume 17, Number 4.
Keywords: finite element method; instrumentation; load tests; cable-stayed; bridges
|
Comunicação
Info
On-site study of the time-dependent behaviour of concrete: evaluation of the application of EC2 prediction models in Algeria
A study of the time-dependent behaviour of concrete carried out on-site in a viaduct in Algeriaprovides an excellent opportunity to assess the suitability of the use of EC2 in non-Europeancountries. This paper presents creep and shrinkage experimental values measured during five yearsand compares them with the values predicted by EC2 models. A procedure for experimentalidentification of the parameters included in EN1992-1-1 prediction models of is proposed and tested.
Year: 2018
Number Pages:
53-61 a 53-68pp.
Author(s): Oliveira Santos, L.; Xu, Min; Vieira,T.
Editor: IABSE - International Association for Bridges and Structural Engineering
Keywords: On-site behaviour; Predictive models; Shrinkage; Creep; Concrete
Info
A Bayesian approach to the use of in-situ specimen data for predicting creep compliance
This paper adopts a Bayesian approach to the problem of creep deformation pre-diction by combining Monte Carlo simulation on an available model with in-situ measurements obtained from in-situ small concrete specimens over a period of six years. Both single point-in-time and sequential updating approaches are de-veloped and demonstrated. It is concluded that for the specific structure exam-ined, the sequential updating method offers advantages in terms of the estimated variability of future predictions.
Year: 2017
Number Pages:
8.
Author(s): Sousa, H. M.; Oliveira Santos, L.; Chryssanthopoulos, M.
Editor: IASSAR - International Association for Structural Safety and Reliability
Keywords: Monte Carlo simulation; in-situ experimental data; creep; Bayesian approach
Info
Dynamic assessment of the São João Bridge structural integrity
São João Bridge, crossing the River Douro, in Oporto, is open to traffic since 1991. It is a prestressed concrete bridge, with a main span of 250 m and a total length of 1028 m. Its structural behaviour has been monitored since construction. In 2014, a vibration-based continuous monitoring system was installed on the bridge. An integrated procedure was developed to automatically carry out the data processing and to extract the modal parameters in real time, using the Stochastic Subspace Identification technique (SSI) and cluster analysis. This paper presents the evolution of its structural health monitoring system, as well the procedure developed for the dynamic assessment of the São João Bridge. Some experimental results are presented and compared with the values predicted by a finite element model. The influence of both environmental conditions and operational factors is discussed.
Year: 2017
Number Pages:
7p.
Author(s): Xu, Min; Oliveira Santos, L.
: Procedia Structural Integrity
Editor: Elsevier B.V.
Volume:
Volume 5, Pages 1-1454 (2017).
Keywords: Structural integrity; Structural health monitoring
Info
Thermal behaviour of a concrete cable-stayed bridge in Algeria
The Salah Bey Viaduct located in the city of Constantine, Algeria, is a cable-stayed bridge with a total length of 756 m and a 259 m main span. Its two pylons have a total height of 130 m and the deck is a prestressed box-girder 3.75 m high with large lateral cantilevers.A comprehensive structural health monitoring system was set up during construction, including a large number of sensors and covering different aspects, as the weather conditions or the static, dynamic and seismic structural behaviours.Since the environmental conditions in Constantine involve large daily and seasonal thermal amplitudes, this paper has the purpose to characterize these thermal variations and to analyse its structural effects.
Year: 2017
Author(s): Oliveira Santos, L.; Xu, Min; Vieira,T.
Editor: IABSE - International Association for Bridges and Structural Engineering
Keywords: thermal behaviour; structural health monitoring; prestressed concrete bridge; Cable-stayed Bridge
Info
Avaliação da condição estrutural baseada nos ensaios de medições de vibrações ambiente
A avaliação do estado de conservação de estruturas é uma atividade cuja importância tem vindo a aumentar, permitindo ao dono de obra uma decisão fundamentada quanto às ações a empreender, contribuindo assim para uma adequada gestão do património construído.As características dinâmicas de uma obra refletem o seu comportamento estrutural global, pelo que se tem recorrido a ensaios in-situ para determinação dos parâmetros dinâmicos de obras, nomeadamente, ensaios de medição de vibração induzidas pela utilização das estruturas e pelas condições ambientais onde se inserem as obras. Estes ensaios têm a vantagem de poderem ser realizados sem recurso a vibrações forçadas e sem restrições à utilização das obras, pelo que no caso de pontes e viadutos não são necessárias interrupções de tráfego.Nesta comunicação apresenta-se o caso de aplicação dessa técnica de ensaios numa ponte com mais de 30 anos de serviço, que apresenta danos claramente visíveis nos seus elementos estruturais, em parte resultantes de reações expansivas no betão. Nessa obra efetuaram-se cinco ensaios de caracterização dinâmica durante 3 anos, permitindo acompanhar a evolução do seu estado de conservação geral e quantificando os efeitos do processo evolutivo inerente às reações expansivas no betão no comportamento estrutural global.
Year: 2016
Number Pages:
12p.
Author(s): Xu, Min; Santos, Teresa O.
Editor: Laboratório Nacional de Engenharia Civil
Keywords: Reações expansivas no betão; Pontes; Condições ambientais; Caracterização dinâmica; Avaliação de danos
Info
Avaliação da resistência à fadiga de pontes metálicas da Linha de Sena, em Moçambique
Na presente comunicação apresenta-se o estudo de avaliação da resistência à fadiga da Ponte Dona Ana, sobre o rio Zambeze, em Moçambique. Este estudo fez parte da avaliação da resistência à fadiga de um conjunto mais alargado de pontes da Linha de Sena e foi realizado pelo Laboratório Nacional de Engenharia Civil, por solicitação da Mota-Engil Ferrovias.Com base no tráfego atual e na evolução esperada, e tendo em conta as diversas ações e as características geométricas e mecânicas das estruturas efetuou-se a avaliação da resistência à fadiga utilizando o método do dano acumulado, tendo-se considerado as categorias de pormenor que melhor representam os elementos analisados. Para tal, simulou-se a influência da passagem dos comboios, recorrendo a um programa de cálculo automático de estruturas baseado no método dos elementos finitos e efetuaram-se análises para cada um dos diversos tipos de vigas que constituem a Ponte Dona Ana e para os vários cenários de carregamento dos comboios reais.
Year: 2016
Number Pages:
11p.
Author(s): Coelho, T.; Silveira, A. P. C. da; Pipa, M.; Asseiceiro, F.; Hipólito, A.
Editor: Centro Rodoferroviário Português
Keywords: Linha de Sena; Ponte ferroviária; Método do dano acumulado; Fadiga
Info
Long-term performance of prestressed concrete bridges
This article provides an overview regarding the SHM and assessment of prestressed concretebridges is performed, mainly focussing on the identification of performance indicators (PI) associated with the long-term performance. The critical aspects related to the monitoring plan as well as the structural assessment based on updated structural models are outlined, being the latter considered as the bottom line of any further considerations. Although the definition of PI devoted to the long-term behaviour of prestressed concrete bridges is not straightforward, two definitions of PI are suggested by taking into account the two main components of the bridge: (i) bearing and expansion joints and (ii) the prestressed concrete structure. Finally, two examples - Lezíria Bridge and Miguel Torga Bridge - are presented in order to illustrate the benefit in using SHM in the assessment of the long-term performance due to creep and shrinkage effects. It is showed that a reduction in the associated uncertainty is achieved and consequently, costs associated with bridge management can be potentially optimized.
Year: 2016
Number Pages:
10.
Author(s): Sousa, H.; Oliveira Santos, L.
Editor: NDT net
Keywords: Long-term performance; Performance indicators; Concrete; Bridges
Info
Modal identification of bridges based on continuous dynamic monitoring
The identification of modal parameters of bridges based on ambient vibration measurements has motivated an increased interest as a tool for detection and diagnosis of small changes in vibratory characteristics and, thus, provides important information to support an efficient maintenance policy. However, the large volume of data continuously produced by a dynamic monitoring system requires an automatic data processing to extract the modal parameters. This paper presents an integrated system developed for this purpose and its application to the data collected from a large cable-stayed bridge.
Year: 2016
Number Pages:
10p.
Author(s): Xu, Min; Vieira,T.; Oliveira Santos, L.
Editor: Alfredo Güemes; Gerardo Aranguren; Fernando Martinez
Keywords: Cable-stayed bridge; SSI-COV; Dynamic monitoring; Ambient vibration; Modal identification
Info
Monitorização da integridade estrutural do Viaduto Salah Bey em Constantine, na Argélia
O Viaduto Salah Bey em Constantine, na Argélia, é uma estrutura de betão armado pré-esforçado, composta por duas torres e nove tramos, três dos quais suspensos através de tirantes dispostos em semi-harpa. O comprimento total do viaduto é de 756 m, possuindo os tramos atirantados vãos de 119 m, 259 m e 105 m. As torres, constituídas por um fuste único e monolíticas com o tabuleiro, têm uma altura total de cerca de 130 m, metade da qual acima do tabuleiro. A secção transversal do tabuleiro, com uma largura de 27,2 m, é constituída por um caixão com duas almas inclinadas e um banzo inferior com geometria côncava, que é dotado de diafragmas afastados entre si de 7,0 m.A monitorização do viaduto visou a preservação da sua segurança estrutural e durabilidade, constituindo um importante auxiliar na gestão da infraestrutura. Na sequência dos exigentes requisitos de projeto, o sistema de monitorização instalado inclui diversas vertentes: condições meteorológicas; comportamento estrutural estático, dinâmico e sísmico; durabilidade; e o estudo do comportamento diferido do betão. No final da construção o viaduto foi sujeito a ensaios estáticos e dinâmicos.Nesta comunicação descreve-se o sistema de monitorização instalado, que compreende mais de 200 sensores, destacando-se os aspetos menos comuns, tanto ao nível dos sensores, como do sistema de aquisição, gestão e transmissão de dados. São também apresentados alguns resultados mais relevantes.
Year: 2016
Number Pages:
11p.
Author(s): Oliveira Santos, L.; Xu, Min; Santos, Carlos; Vieira,T.; Roma, J.
Editor: GPBE
Keywords: Comportamento térmico de ponte; Análise modal operacional; Monitorização de integridade estrutural; Ponte atirantada
Info
Monitorização das medidas de mitigação das reações expansivas do betão na Ponte do rio Sabor na N315
O crescente número de estruturas de betão afetadas por reações expansivas, em particular com reação álcalis-sílica (RAS) e reação sulfática interna (RSI), tem motivado numerosos estudos visando a prevenção, o diagnóstico e a mitigação deste fenómeno.O presente trabalho apresenta um caso de estudo de uma ponte sobre o rio Sabor, no Norte de Portugal, cujos pilares principais foram submersos devido à construção de uma barragem a jusante. Nestas circunstâncias, foi realizada uma campanha de ensaios para avaliar a condição atual do betão e o potencial de expansão futuro devido à RAS e RSI. Os resultados obtidos mostraram existir uma forte possibilidade de desenvolvimento desses fenómenos, pelo que foi recomendado, como medida mitigadora, a aplicação de um sistema de impermeabilização do betão dos pilares da ponte, antes do enchimento da albufeira, uma vez que o aumento do grau de saturação do betão tem influência significativa no desenvolvimento destas reações.Para avaliar o desempenho do sistema de impermeabilização e detetar precocemente os efeitos estruturais resultantes duma eventual ocorrência de reações expansivas no betão, foi instalado um sistema de monitorização que inclui a medição da humidade no interior do betão de um pilar, tendo-se utilizado, para esse efeito, dois tipos distintos de sensores.Depois de uma breve descrição da ponte e do processo adotado para mitigar o desenvolvimento das reações expansivas internas no betão, o foco desta comunicação é a apresentação do sistema de monitorização concebido e dos principais resultados obtidos.
Year: 2016
Number Pages:
13.
Author(s): Oliveira Santos, L.; Pereira, E. V.; Santos Silva, A.; Ribeiro, A. C.; Xu, Min
Editor: LNEC
Keywords: Monitorização; Mitigação; Ponte de betão; Reações expansivas
|
Tese de Doutoramento
Info
Retracção do betão em pontes
A retracção tem uma importância significativa na concepção, dimensionamento, processoconstrutivo e comportamento em serviço de grandes estruturas de betão. No entanto, não estãoainda completamente esclarecidos os mecanismos básicos a ela inerentes e o modo comointeragem entre si, além de que os modelos de previsão não consideram de forma adequada ainfluência dos factores que a determinam.Os objectivos desta dissertação prendem-se com o estudo da retracção do betão e suasconsequências estruturais em pontes, aprofundando e desenvolvendo trabalhos anteriormenteefectuados neste domínio.Neste sentido, foi planeada uma extensa campanha de ensaios em provetes tendo em vista, aavaliação da influência da espessura das peças, a quantificação da retracção diferencial que seprocessa na espessura das peças, a avaliação da influência de diferentes condições ambientais,para além da aferição da metodologia experimental utilizada pelo Núcleo do Observação deEstruturas do LNEC.Foi também realizado um conjunto de ensaios com vista a obter um melhor esclarecimento darelação entre a retracção de provetes de betão colocados em obra e a retracção que ocorre nassecções dos tabuleiros em caixão de pontes. Para tal, foram executados e instrumentadospainéis de parede de betão que foram mantidos em condições ambientais semelhantes às dasalmas de um tabuleiro em caixão, isto é, uma das faces sujeita a ambiente interior e a outra aambiente exterior e, simultaneamente, foi também avaliada a retracção do mesmo betão emprovetes colocados nesses diferentes ambientes. Com a informação obtida foi possível, por umlado, avaliar a retracção das peças sujeitas a diferentes ambientes em duas superfícies opostase, por outro lado, esclarecer qual a relação entre a retracção medida em provetes de betão e aretracção que ocorre nos elementos estruturais cujas faces opostas estão sujeitas a essesdiferentes ambientes.Com base nos resultados obtidos nos ensaios realizados, foi proposta uma metodologia para amodelação do comportamento estrutural de pontes que considera a não uniformidade daretracção do betão na secção transversal do tabuleiro. Essa metodologia, que consiste naconsideração integrada de um modelo longitudinal global da estrutura e de modelos locais dasaduelas, tirando partido da informação experimental disponível sobre a retracção, foi aplicada àspontes S. João e Miguel Torga, cujo comportamento estrutural é observado pelo LNEC.Por último, apresentam-se as principais conclusões do trabalho e formulam-se algumasperspectivas sobre o seu desenvolvimento futuro.
Year: 2007
Author(s): Santos, T.
|
Relatório Científico
Info
Relatório de atividades do Núcleo de Observação de Estruturas no ano de 2023
O presente documento visa apresentar de forma sucinta as atividades desenvolvidas pelo Núcleo deObservação de Estruturas do Departamento de Estruturas durante o ano de 2023. A atividade desenvolvida está apresentada de acordo com as vertentes habitualmente consideradas no LNEC, isto é, i) Investigação e Inovação; ii) Estudos e pareceres; iii) Outras atividades científicas e técnicas. Este relatório inclui também uma caracterização dos recursos humanos afetos ao núcleo, bem como da faturação externa obtida.
Year: 2024
Author(s): Oliveira Santos, L.
Keywords: Núcleo de Observação de Estruturas; Relatório de atividade
Info
Software DT500COM - Controlo dos Geologgers da Série DT500, da Datataker
Neste relatório apresenta-se o software desenvolvido para controlo das subunidades de aquisição Geologger série 500, da Datataker. Para além de se fornecerem indicações para trabalhar com o software referido, é feita uma apresentação do projeto desenvolvido na linguagem de programação C#.
Year: 2016
Author(s): Silveira, A. P. C. da; Barateiro, J.
Keywords: C#; Data logger; Porta série
Info
OPÇÕES E PARÂMETROS ADOPTADOS NO ANEXO NACIONAL DA EN-1991-1-5
Em 1975 a Comunidade Económica Europeia adoptou um programa de acção tendente aharmonizar as especificações técnicas e a eliminar entraves técnicos, na área daconstrução.Neste sentido foram criadas regras técnicas para o projecto de estruturas, que numaprimeira fase coexistiriam com as regras preconizadas na regulamentação nacional, masque posteriormente as deveriam substituir.Deste modo encontra-se em fase final de desenvolvimento um conjunto de EurocódigosEstruturais, dos quais faz parte o Eurocódigo 1
Year: 2008
Number Pages:
40pp.
Author(s): Silveira, A. P. C. da
Keywords: Parâmetros adoptados; Opções; En-1991-1-5; No anexo nacional
Info
Materiais metálicos. Arames. Ensaio de dobragem alternada. Projecto de revisão da NP 851 (1971)
O presente trabalho apresenta um projecto de revisão da Norma Portuguesa NP 851 (1971)
Year: 1991
Author(s): Baptista, A. M.
Keywords: Normalização; Ensaio de Dobragem Alternada; Arames; Materiais metálicos
Info
Materiais metálicos. Ensaio de dureza. Ensaio Vickers. 1ª Parte: HV5 a HV100. Projecto de Norma Portuguesa.
O presente trabalho apresenta um projecto de Norma Portuguesa relativo ao ensaio de dureza Vickers (HV5 a HV100) de materiais metálicos, e insere-se numa série de estudos programados pelo autor, enquanto coordenador da normalização nacional no domínio dos ensaios mecânicos, físicos e não-destrutivos de materiais metálicos, a fim de actualizar as Normas Portuguesas existentes neste domínio.O texto apresentado consiste na versão final de uma proposta redigida pelo autor, na sequência dos estudos efectuados ao nível da Comissão Técnica de Normalização competente.
Year: 1990
Author(s): Baptista, A. M.
Keywords: Normalização; Ensaio Vickers; Ensaio de dureza; Materiais metálicos
|