Papers
Info
Deterioration Models and Service Life Prediction of Vertical Assets of Urban Water Systems
This study proposes a methodology for developing deterioration models and predicting the service lives of vertical assets of urban water systems (i.e., water storage tanks and pumping stations) using regression analysis. The main factors contributing to the deterioration of these assets are analyzed. Simple and multiple linear regression models of average and maximum deterioration are calculated for 22 water storage tanks and 17 wastewater pumping stations. Data on a set of four water storage tanks are used to validate the developed deterioration models. Service life prediction is carried out using the developed models and considering two maximum deterioration levels: the maximum recommended and admissible deterioration levels. Two water storage tanks are further studied to illustrate and discuss the effect of maintenance and rehabilitation interventions on asset service life by comparing the asset deterioration before and after the interventions.
Year: 2024
Number Pages:
19p..
Author(s): Cabral , M.; Loureiro, D.; Amado, C; Covas, D.
: Water Resources Research
Editor: AGU
Volume:
Volume 60, Issue 4.
Keywords: Urban water systems; Service life prediction; Deterioration models
Info
Integrating Uncertainty in Performance Assessment of Water Distribution Networks by Scenario Building
This paper presents and demonstrates a novel scenario-building methodology that integrates contextual and future time uncertainty into the performance assessment of water distribution networks (WDNs). A three-step approach is proposed: (i) System context analysis, identifying the main key factors that impact the WDN performance; (ii) Scenario definition, identifying the implicated WDN variables, describing its possible evolution, and conjugating them to further establish the reference scenario and the two most relevant and opposite ones; and (iii) Scenario modelling, simulating the WDN behaviour for those scenarios. The obtained spatial and temporal hydraulic results are further used to calculate performance metrics. The methodology is applied to a real WDN to assess resilience performance considering infrastructure asset robustness (real water loss performance indicator), service reliability (minimum pressure index), and service flexibility (network resilience index). A new formulation to assess the metric evolution over time is proposed, deducting the further-away performance results by using an uncertainty weight. The results demonstrate that the increase in metric amplitude for the opposite scenarios over time highlights future uncertainty, reflecting context uncertainty, and the comparison of metric spatial distribution (i.e., at the pipe/node levels) highlights critical areas with higher associated uncertainty.
Year: 2024
Number Pages:
18p..
Author(s): Carneiro, J.; Loureiro, D.; Cabral , M.; Covas, D.
: Water
Editor: MDPI
Volume:
Volume 16, Issue 7.
Keywords: Resilience metrics; Scenario modelling; Scenario planning; Aleatory uncertainty; Drinking water networks
Info
A comprehensive performance assessment system for diagnosis and decision-support to improve water and energy efficiency and its demonstration in Portuguese collective irrigation systems.
In regions with a strong seasonal or interannual asymmetry in the distribution of precipitation and higher frequency of droughts, collective irrigation systems are vital infrastructures for agricultural activity. Although operating for decades, several systems have ageing infrastructures, with relevant water losses and pumping energy inefficiencies. Consequently, the systems are not adequately designed or operated to meet current and future water demand. Therefore, rehabilitation to improve water and energy efficiency while ensuring infrastructure, economic sustainability and service quality is crucial. In this sense, comprehensive approaches using performance assessment to support the planning process or benchmarking between water users associations play an essential role in improving efficiency in collective irrigation systems.
Year: 2023
Number Pages:
15p..
Author(s): Loureiro, D.; Beceiro, P.; Moreira, M.; Arranja, C.; Cordeiro, D.; Alegre, H.
: Agricultural Water Management
Editor: Elsevier
Volume:
Vol- 275.
Keywords: Water Users Association; Water and energy efficiency; Performance assessment system; Decision support; Diagnosis; Collective irrigation systems
Info
Energy efficiency assessment in collective irrigation systems using water and energy balances: methodology and application
Many collective irrigation systems have been operating for decades, facing high degradation of existing infrastructures and huge water-energy efficiency problems. Predominantly composed of open canals, they have been partially or entirely converted into pressurised pipe systems, implying a considerable increase in energy consumption and operation and maintenance costs. Simple, easy-to-use, and comprehensive approaches for energy efficiency assessment in collective irrigation systems are needed for diagnosis and assisting decision-making on implementing adequate improvement measures. This research proposes and demonstrates an innovative approach based on the water and energy balances and performance indicators to assess the effect of water losses, network layout and operation, energy recovery, and equipment on energy efficiency. A novel methodology for energy balance calculation is proposed for open canal, pressurised and combined systems. The application to a real-life open canal system and network areas allowed the identification of efficiency problems mainly due to water losses in canals, followed by the dissipated energy in friction losses. Less critical are pumping and manoeuvring equipment inefficiencies. Also, a considerable excess of gravity energy is recovered in hydropower plants. In raising pipe systems, in which shaft input energy predominates and costs for pumping play a key role, surplus and dissipated energy in friction losses are the most relevant issues. Significant energy is lost in the water conveyance and distribution in both systems. Consequently, the potential to improve energy efficiency through water loss management, network layout, and operation improvement, besides pumping and manoeuvring equipment replacement, is considerable.
Year: 2023
Number Pages:
24p..
Author(s): Loureiro, D.; Beceiro, P.; Fernandes, E.A.; Alegre, H.; Covas, D.
: Irrigation Science
Editor: Spinger
Keywords: Water and energy balances; Irrigation systems; Energy efficiency
Info
Exploratory Analysis of Surrogate Metrics to Assess the Resilience of Water Distribution Networks
This study compares and discusses the adequacy of surrogate resilience metrics proposed in the literature for resilience assessment of drinking water systems concerning demand increase and network redundancy. A sensitivity analysis is carried out for increasing flow rates using a conceptual case study with different layouts and demand scenarios, selecting several metrics to assess the resilience of two real network areas. Resilience metrics based on surplus energy are sensitive to network layout and demand scenarios. The network resilience index considers hydraulic reliability and network diameter uniformity. In contrast, the weighted resilience index also considers the network topology and gives importance to pipes with higher flow rates. Entropy-based resilience metrics mainly rely on the network flows' uniformity and are sensitive to pipe redundancy. The entropy metric most adequate to assess the hydraulic capacity is the diameter-sensitive flow entropy, since it is sensitive to the velocity inside the pipes. Topology metrics cannot assess the hydraulic capacity though evaluate the system redundancy (meshed-ness coefficient), robustness (central-point dominance) and water transportation efficiency (average-path length). Surrogate resilience metrics do not assess the system performance during a failure. They indicate systems which are better prepared to overcome failure events and increased demand events, providing vital information to drinking water systems management.
Year: 2023
Number Pages:
16p..
Author(s): Carneiro, J.; Loureiro, D.; Covas, D.
: Water Resources Research
Editor: AGU
Volume:
Volume 59, Issue 8.
Keywords: Water Distribution Networks; Resilience; Surrogate Metrics
Info
From assessment to a decision: a global framework for the management of energy use in wastewater systems
A global framework to assess the energy use and efficiency in wastewater systems is presented, focusing on the development of a portfolio of energy use improvement measures specifically tailored to these systems. The framework includes a performance assessment system for energy efficiency in wastewater systems and an energy balance scheme. The development and analysis of the portfolio of measures included the following steps: (i) an extensive review and compilation of existing energy improvement measures on the urban water cycle, (ii) a tailored survey addressed to multidisciplinary teams of wastewater utilities, (iii) the consolidation of the portfolio of measures for wastewater systems with the identification of main benefits and drawbacks of each measure and (iv) the discussion of the application of the improvement measures. Results from the survey for the different assessed dimensions (e.g., priority, importance) of each measure are presented together with a specific analysis of wastewater utilities. The final portfolio is instrumental for utilities to select measures, decide on the priority ones and prepare an implementation plan.
Year: 2023
Number Pages:
16p..
Author(s): Jorge, C.; Almeida, M. C.; Covas, D.
: International Journal of Environmental Science and Technology
Editor: Spinger
Keywords: Wastewater systems; Portfolio; Improvement measures; Energy efficiency
Info
Implementação e calibração de um modelo de decaimento de cloro em sistemas de distribuição de água para reutilização
Com secas cada vez mais frequentes e prolongadas em Portugal, é necessário repensar medidas que permitam enfrentar a falta de água. A água residual tratada constitui uma fonte de água alternativa, a ser utilizada como água para reutilização (ApR) em usos compatíveis, como rega de espaços verdes e lavagem de ruas.A modelação do decaimento de cloro em Sistemas de Distribuição de ApR (SDApR) carece de estudos que proponham metodologias de implementação dos modelos, técnicas de trabalho experimental a nível laboratorial e exemplos de aplicação à escala real. A modelação contribui para promover uma gestão eficaz da desinfeção da ApR, ajudando a determinar dosagens de desinfetante, concentrações residuais nas redes e locais de cloragem.Neste artigo apresenta-se uma metodologia para modelar o decaimento de cloro em ApR usando o software EPANET-MSX. A metodologia envolveu três fases: desenvolvimento do modelo hidráulico, modelação do decaimento de cloro na água e modelação do decaimento de cloro devido às paredes do reservatório e condutas. O modelo foi aplicado num SDApR da área de Lisboa e calibrado com ensaios à escala real, permitindo simular o decaimento de cloro em diferentes pontos do SDApR ao longo do tempo e prever as necessidades de doseamento de cloro
Year: 2023
Number Pages:
12p..
Author(s): Costa, J.; Mesquita, E.; Ferreira, F.; Figueiredo, D.; Rosa, M. J.; Viegas, R.M. C.
Editor: APDA
Keywords: Epanet-MSX; Sistemas de distribuição de água para reutilização; Modelação do decaimento de cloro; Água para reutilização
Info
Improving climate resilience of critical assets. The ICARIA project
The number of climate-related disasters has progressively increased in the last two decades and this trend will drastically exacerbate in the medium- and long-term horizons according to climate change projections. In this framework, through a multi-disciplinary team and a strong background acquired in recent projects, ICARIA aims to promote the use of asset-level modeling to achieve a better understanding of climate related tangible direct and indirect impacts on critical assets due to complex, cascading, and compound disasters. Furthermore, it takes into account the related risk reduction provided by suitable, sustainable, and cost-effective adaptation solutions. ICARIA focuses on both (i) critical assets and services that were not designed for potential climate change-related impacts that can increase the unplanned outages and failures, and (ii) on housing, natural areas, and population. Cutting edge methods regarding climate scenario building, asset-level-coupled models, and multirisk assessment approaches will be implemented and replicated in three EU regions to understand how future climate scenarios might affect critical assets and to provide decision-making support tools to private and public risk owners to assess the costs and benefits of various adaptation solutions.
Year: 2023
Number Pages:
14p..
Author(s): Russo, B.; de la Cruz, A.; Leonne, M.; Evans, B.; Brito, R.; Havlik, D; Bügelmayer-Blaschek, M.; Pacheco, D.; Sfetsos, A.
: Sustainability
Editor: MDPI
Volume:
Volume 15, Issue 19.
Keywords: Cascading effects; Compound events; Asset modeling; Climate resilience; Critical assets
Info
Improving mixing and renewal in drinking water storage tanks: lessons learnt and practical measures
This paper investigates the effect of different types of structural and operational measures on water mixing and renewal time in circular and rectangular cross-section water storage tanks, aiming at a better understanding of the flow dynamics to find practicable solutions to improve their design, rehabilitation and operation. An experimental programme, including traditional tracer and dye tracer tests, was carried out in small-scale tanks for different configurations and operating conditions. Two tanks were tested with and without interior structures, with the inlet/outlet pipes at different locations and for constant and variable water level. The main findings are that: i) the most effective measure is operating with fill-and-draw cycles, however, for tanks operated nearly full structural measures are recommendable; ii) reducing the inlet pipe diameter and installing nozzles near the tank bottom improve the mixing conditions; iii) the use of baffles is recommendable when the inlet and outlet pipes are very close.
Year: 2023
Number Pages:
13p..
Author(s): Pinheiro, A.; Vaz, S.; Monteiro, L.; Almeida, M. C.; Covas, D.
: Urban Water Journal
Editor: Taylor and Francis
Volume:
Volume 20, nº 7.
Keywords: Improvement measures; Short-circuiting; Water renewal; Water mixing; Water storage tanks
Info
Improving the pharmaceutical compounds control in two activated sludge wastewater treatment plants: key operating conditions and monitoring parameters
The control of pharmaceutical compounds (PhCs) in urban wastewater treatment plants (WWTPs) is an issue of health and environmental relevance, expected to become mandatory in the European Union and beyond, but studies at full scale are still scarce. A long-term (2.5-year) full-scale study addressing practical strategies for controlling PhCs was conducted in two activated sludge WWTPs with nitrification (BEI with A2O process; FNW with oxidation ditch). The results showed similar removal patterns in both plants
Year: 2023
Number Pages:
14p..
Author(s): Silva, C.; Almeida, C.M.M.; Rodrigues, J.A.; Sofia, S.; Coelho, R.; Martins, A.; Lourinho, R,; Cardoso, E.; Cardoso, V.V.; Benoliel, M. J.; Mesquita, E.; Ribeiro, R.; Rosa, M. J.
: Journal of Water Process Engineering
Editor: Elsevier
Volume:
54.
Keywords: Urban wastewater treatment; Treatment conditions; Pharmaceutical compounds; Biodegradation-sorption classes; Activated sludge treatment
|
Comunicação
Info
Avaliação do funcionamento de um sistema de lagunagem destinado ao tratamento de efluentes de suinicultura
N/A
Year: 2000
Author(s): Ribeiro, R.; Bicudo, J. R.
Editor: ******
Info
Beneficiação de sistemas urbanos de águas residuais desafios e estratégias para o futuro
N/A
Year: 2000
Author(s): Matos, J. S.; Matos, R. S.; Frazão, A.
Editor: ******
Info
Benefícios da análise hidráulica de sistemas separativos domésticos através de modelação matemática
N/A
Year: 2000
Author(s): Cardoso, M. A.; Almeida, M. C.; Brito, R. S.
Editor: ******
Info
Certificação de qualidade e indicadores de desempenho
N/A
Year: 2000
Author(s): Alegre, H.
Editor: ******
Info
Decaimento do cloro em sistemas de distribuição de água
N/A
Year: 2000
Author(s): Vieira, P.; Coelho, S. T.
Editor: ******
Info
Enhanced naphtalene-biovalailability in a liquid-liquid biphasic system
N/A
Year: 2000
Number Pages:
309-320.
Author(s): Menaia, J.; Freixo, M.; Girio, F.
Editor: ******
Info
Especificação de materiais para as redes de abastecimento de água de Oeiras e Amadora
N/A
Year: 2000
Number Pages:
13 p.
Author(s): Moreira, E.; Machado, F.; Marques, J.; Melo Baptista, J.; Alegre, H.
Editor: ******
Info
Estado de conservação e práticas de manutenção de sistemas de distribuição de água em Portugal
N/A
Year: 2000
Number Pages:
14 p.
Author(s): Figueiredo, S.; Duarte, P.; Alegre, H.; Carvalho, R. F.
Editor: ******
Info
Indicadores de desempenho para serviços de abastecimento de água
N/A
Year: 2000
Author(s): Alegre, H.; Melo Baptista, J.
Editor: ******
Info
Les indicateurs de performance de l Association internationale de l eau
N/A
Year: 2000
Number Pages:
12 p.
Author(s): Alegre, H.
Editor: ******
|
Books
Info
Quality Assessment Guide for Water and Waste Services Provided to Users: 4th Generation Assessment System
The Technical Guide presents the 4th generation of the service quality assessment system, which abandons some 3rd generation indicators and adds new ones to respond to the latest challenges to supply services, urban waste water management and urban waste management. Changes are also made to definitions and benchmarks for some indicators are adjusted.
Year: 2023
Number Pages:
345p..
Author(s): Cardoso, M. A.; Rosa, M. J.; Brito, R.; Silva, C.; Beceiro, P.; Jorge, C.; Alegre, H.; Martinho, G.; Pina, J.; Silveira, A.; Alves, A.V.; Brito Ana, J.; Ramos, M.; Carrega, M.
Editor: ERSAR/NOVA
Keywords: Benchmarking; Performance indicators; Waste services; Water services; Quality assessment
Info
Avaliação da eficiência energética nos serviçoes urbanos de águas. Guia para diagnóstico, priorização de alternativas, nonitorização e revisão do plano de ação
O projeto Avaler+
Year: 2021
Number Pages:
55 pp..
Author(s): Loureiro, D.; Silva, C.; Cardoso, M. A.; Alegre, H.; Cabral , M.; Covas, D.; Rosa, M. J.
Editor: LNEC
Keywords: Serviços urbanos de águas; Plano de ação; Eficiência energética; Diagnóstico; Avaliação de desempenho
Info
Technical Guidelines PAC/MF
These technical guidelines provides guidance on the use of the hybrid process of powdered activate carbon adsorption and ceramic microfiltration for sustainable drinking water production. They were developed based on the field demonstration of the technology, in Portugal, with a pilot prototype, within the LIFE Hymenb project LIFE12 ENV/PT/001154 "Tailoring hybrid membrane processes for sustainable drinking water production", conducted by LNEC - the National Civil Engineering Laboratory and Águas do Algarve, S.A.
Year: 2017
Number Pages:
29 p.
Author(s): Campinas, M.; Viegas, R.M. C.; Silva, C.; Rosa, M. J.
Editor: LNEC
Keywords: Technical guidelines; LIFE Hymemb; Emerging contaminants; Drinking water treatment; Ceramic microfiltration; Activated carbon adsorption
Info
Guia de avaliação da qualidade dos serviços de águas e resíduos prestados aos utilizadores - 2ª Geração do sistema de avaliação
O objetivo do presente Guia é a apresentação e a especificação dosistema correspondente à 2.ª geração de avaliação da qualidade dosserviços de abastecimento de água, de saneamento de águas residuaisurbanas e de gestão de resíduos urbanos prestados pelas entidadesgestoras sujeitas a regulação.Este sistema constitui uma peça fundamental do modelo de regulaçãoem implementação pela ERSAR, sumariamente descrito neste Guia emais detalhadamente descrito em [1], nomeadamente no que respeitaà componente da regulação da qualidade do serviço, de forma a tornarpossível a avaliação quantificada.Note-se que, de acordo com o disposto na alínea e) do n.º 1 do artigo 5.ºdo Decreto-Lei n.º 277/2009, de 2 de outubro, a ERSAR tem atribuiçõesnão apenas para assegurar a regulação da qualidade de serviço prestadoaos utilizadores pelas entidades gestoras, mas também para avaliaro desempenho dessas entidades, promovendo a melhoria dos níveis deserviço. É no quadro destas atribuições que se pretende promover estesistema de avaliação da qualidade dos serviços de águas e resíduos.A 2.ª geração do sistema de avaliação da qualidade do serviço resultouda análise crítica do sistema de indicadores adotado na 1.ª geração e darespetiva aplicação desde 2004 ao universo das entidades concessionáriase teve em conta o estado atual de conhecimentos e a experiênciainternacional entretanto adquirida.Para além da identificação e da especificação de todos os componentesdo sistema de avaliação, e em particular do conjunto de indicadores dequalidade do serviço a utilizar em cada um dos três tipos de serviços,são também definidos os procedimentos de avaliação, através dadefinição da informação a obter, do cálculo de indicadores, da sua interpretaçãoe análise comparativa, numa perspetiva de benchmarking, eda produção do relatório de síntese.
Year: 2012
Number Pages:
256p.
Author(s): entidade LNEC
Editor: ERSAR/LNEC
Info
Adaptação e Sustentabilidade de Serviços de Abastecimento de Água e de Águas Residuais - RESUMOS
N/A
Year: 2010
Number Pages:
425p.
Author(s): entidade LNEC
Editor: APESB
Info
Gestão patrimonial de infra-estruturas de abastecimento de água - Uma abordagem centrada na reabilitação
O texto está organizado em três partes e um conjunto de anexos (Figura 1.1). A primeira parte é de enquadramento geral, na segunda apresenta
Year: 2010
Number Pages:
510p.
Author(s): Covas, D.; Alegre, H.
Editor: ERSAR / LNEC / IST
Keywords: Sistema de abastecimento de água; Rede de distribuição; Legislação; Guia; Eta; Captação de água; Água; Adutora
Info
Gestão patrimonial de infra-estruturas de águas residuais e pluviais - Uma abordagem centrada na reabilitação
A gestão patrimonial de infra
Year: 2010
Number Pages:
362p.
Author(s): Almeida, M. C.; Cardoso, M. A.
Editor: ERSAR / LNEC
Keywords: Sistema de drenagem de águas residuais; Saneamento; Guia; Etar; Emissário
Info
Guia de avaliação da qualidade dos serviços de águas e resíduos prestados aos utilizadores. 2ª Geração do sistema de avaliação
O objectivo do presente Guia é a apresentação e a especificação do sistema correspondente à 2.ª geração de avaliação da qualidade dos serviços de abastecimento de água, de saneamento de águas residuais urbanas e de gestão de resíduos urbanos prestados pelas entidades gestoras sujeitas a regulação. Este sistema constitui uma peça fundamental do modelo de regulação em implementação pela ERSAR, sumariamente descrito neste Guia e mais detalhadamente descrito em [1], nomeadamente no que respeita à componente da regulação da qualidade do serviço, de forma a tornar possível a avaliação quantificada. Note-se que, de acordo com o disposto nas alíneas e) do artigo 5.º do Decreto-Lei n.º 277/2009, de 2 de Outubro, a ERSAR tem atribuições não apenas para assegurar a regulação da qualidade de serviço prestado aos utilizadores pelas entidades gestoras bem como para avaliar o desempenho dessas entidades, promovendo a melhoria dos níveis de serviço. É no quadro destas atribuições que se pretende promover este sistema de avaliação da qualidade dos serviços de águas e resíduos. A 2.ª geração do sistema de avaliação da qualidade do serviço resultou da análise crítica do sistema de indicadores adoptado na 1.ª geração e da respectiva aplicação desde 2004 ao universo das entidades concessionárias e teve em conta o estado actual de conhecimentos e a experiência internacional entretanto adquirida. Para além da identificação e da especificação de todos os componentes do sistema de avaliação, e em particular do conjunto de indicadores de qualidade do serviço a utilizar em cada um dos três tipos de serviços, são também definidos os procedimentos de avaliação, através da definição da informação a obter, do cálculo de indicadores, da sua interpretação e análise comparativa, numa perspectiva de benchmarking, e da produção do relatório de síntese.
Year: 2010
Author(s): entidade LNEC
: ERSAR / LNEC
Info
Strategic Asset Management of Water and Wastewater Infrastructures
Invited papers from the IWA Leading Edge Conference on Strategic Asset Management (LESAM), Lisbon, October 2007
Year: 2009
Number Pages:
536p.
Author(s): Alegre, H.; Almeida, M. C.
Editor: IWA Publishing
Keywords: Infrastructures; Wastewater; Water supply; Asset management
Info
Modelação e análise de sistemas de abastecimento de água
A simulação matemática dos sistemas de abastecimento de água é hoje em dia uma ferramenta indispensável aos serviços de água, para apoio a uma gestão técnica racional. O campo de aplicação é variado, sendo um auxiliar das actividades de planeamento, de projecto, de operação e demanutenção. Destacam-se o apoio ao dimensionamento de novas redes, aos programas de reabilitação, ao licenciamento de novas ligações, ao controlo de perdas de água, ao controlo da qualidade da água nas redes ou à gestão optimizada de energia.Em Portugal, o desenvolvimento e a aplicação de modelos matemáticos de sistemas de distribuição de água iniciou-se na década de 80, com o modelo da rede de Almada, elaborado em 1981 pelo LNEC. Depois dealguns anos em que a actividade realizada se centrou essencialmente no ambiente científico e académico, as empresas de consultoria começaram a ganhar espaço de mercado na prestação deste tipo de serviços para as entidades gestoras. Numa fase inicial os requisitos computacionais eramconsideráveis
Year: 2006
Number Pages:
335.
Author(s): Coelho, S. T.; Loureiro, D.; Alegre, H.
Editor: IRAR / LNEC
Volume:
Série Guias Técnicos nº 4.
Keywords: Água
|
Capítulo de Livro
Info
Sanitation Approaches & Solutions
Water scarcity and asymmetric space-time distribution is driving many countries to seek nonconventional water sources. Treated wastewater is an emerging alternative water source but, depending on its use(s), it may require an increased level of water treatment. At the same time, the list of emerging contaminants (ECs), including pharmaceutical compounds (PhCs), of great relevance to the environment and to public health continues to grow. Further, many of these contaminants are partly or strongly resistant to conventional treatment in water and wastewater treatment plants (WTPs and WWTPs). Therefore, advanced treatment processes are being developed or optimised for improved PhC control. Amongst them, hybrid processes of adsorption
Year: 2018
Number Pages:
pp 97-108.
Author(s): Viegas, R.M. C.; Mesquita, E.; Campinas, M.; Almeida, C.M.M.; Rosa, M. J.
: Sanitation Approaches & Solutions and the Sustainable Development Goals
Editor: ERSAR, EWA, APESB, CERIS
Keywords: Water reuse; Water reclamation; Pharmaceutical compounds; PAC/NF; Hybrid membrane processes
Info
Development of soft sensors based on analytical and spectral data on a real small size wastewater treatment plant
Advances in measurement and automation technologies enabled the deployment of monitoring systems with data acquisition at high frequency in Wastewater Treatment Plants (WWTP). The aim of this work is the design of soft sensors to predict hard-to-measure quality variables of wastewater required for mechanistic modeling of the biological treatment system in a real municipal WWTP. The input data collected in the WWTP using a flowmeter and spectro-photometric and electrochemical online probes, sampling campaigns and on-line analysis, was used for the development of soft sensors by multivariate analysis, like Principal Component Analysis (PCA) and Partial Least Squares (PLS) regression. Exploratory data analysis was performed in order to detect outliers, patterns and correlations. PLS models for soft sensors were developed using leave-one-out cross validation and the predictive capacity of independent data was evaluated by root mean square error (RMSE). The normalized RMSE obtained for organic nitrogen prediction were 19.5% and 18.1%, using sensors with analytical and spectral data, respectively. The possibility of using spectro-photometric probes providing measurements of a single wavelength was evaluated in order to reduce the online monitoring investment costs.
Year: 2017
Number Pages:
323-333pp.
Author(s): Leitão, C.; Fernandes, L.; Ribeiro, R.; Almeida, M. C.; Pinheiro, C. C.; Pinheiro, H. M.
: CONTROLO 2016. Lecture Notes in Electrical Engineering
Editor: Springer
Volume:
vol 402.
Keywords: Partial least squares; Online monitoring; Soft sensors; Wastewater treatment; Prediction; Municipal WWTP
Info
Resiliência e gestão do risco no turismo
Capítulo de livro sobre planeamento e desenvolvimento turístico em que é desenvolvida a temática de resiliência e gestão do risco no turismo. São focados aspetos que incluem conceitos de base em resiliência e risco, as categorias de risco relevantes em turismo, a abordagem estruturada para a gestão do risco da norma ISO 31000:2009 e eixos de atuação para aumentar a segurança e a resiliência no turismo.
Year: 2017
Number Pages:
105-120pp.
Author(s): Almeida, M. C.
: Planeamento e desenvolvimento turístico
Editor: Lidel
Keywords: Turismo; Gestão do risco; Resiliência
Info
Chapter 12: Economic and operational aspects
Municipalities and/or sewer operators have to decide investment strategies to rehabilitate and upgradeboth the efficiency and quality of their sewer systems. Frequently, such decisions are based on limitedinformation and do not consider simultaneously the sewer pipes, the wastewater treatment plant andthe receiving environment, especially groundwater. In order to provide some basic working elements tohelp operators in making such decisions, Work Area 4 (WA4) within the APUSS project, described in thepresent chapter included three topics:i) the definition of a set of infiltration/exfiltration specific performance indicators, PIs;ii) the proposition of a generic multi-criteria methodology to compare investment strategieswhich is elaborated separately in Chapter 10 and;iii) the analysis of cost structures of sewer systems and costings for the new tracer methods proposed in the APUSS methodology (as outlined in Chapter 2).
Year: 2010
Number Pages:
159-167.
Author(s): Cardoso, M. A.; Frehmann, T.
Editor: IWA
Info
Performance indicators as a management support tool, capítulo 9 do livro Urban Water Supply Infrastructure Management Handbook
N/A
Year: 2002
Number Pages:
9.1-9.74.
Author(s): Alegre, H.
Editor: ******
|
Tese de Doutoramento
Info
Gestão patrimonial de infra-estruturas de abastecimento de água e de drenagem e tratamento de águas residuais
Esta publicação corresponde ao Programa de Investigação e ao Programa de Pós-Graduaçãoelaborados pela autora nos termos estabelecidos no artigo 30.º do Decreto-lei n.º 124/99, de20 de Abril, com vista à prestação de provas de habilitação para o exercício de funções decoordenação de investigação científica, realizadas em 31 de Janeiro e 1 de Fevereiro de 2008.Com o Programa de Investigação pretende-se contribuir para o estabelecimento de umaestratégia de desenvolvimento técnico e científico no âmbito da gestão patrimonial deinfra-estruturas de abastecimento de água e de drenagem de águas residuais. Trata-se de umprograma dirigido de forma privilegiada para as necessidades nacionais, mas que atende aocontexto internacional, tendo em vista o papel que o País pode desempenhar nodesenvolvimento do conhecimento nesta matéria, em sentido lato. Propõe-se uma estratégiaassente no estabelecimento de parcerias interdepartamentais e interinstitucionais, ancorada noNúcleo de Engenharia Sanitária do Departamento de Hidráulica e Ambiente do LNEC.Neste documento começa-se por fazer uma apresentação geral do programa, especificando osobjectivos e expondo as razões para a escolha do tema. Propõe-se a seguir uma visita guiadasobre o tema, que permite a um leitor menos familiarizado obter uma panorâmica geral.A sequência de capítulos seguinte é dedicada à apresentação e discussão do estado actual deconhecimentos. Inicia-se pelas abordagens integradas para apoio à GPI, seguindo-se depoispara as principais vertentes de análise na GPI: desempenho, custo e risco.Faz-se seguidamente uma análise de lacunas e prioridades de investigação. Termina-se com aapresentação de um programa de estudos, estruturados em quatro linhas de investigação:Linha 1: GPI
Year: 2009
Author(s): Alegre, H.
Info
Pollutant Transformation Processes in Sewers under Aerobic Dry Weather Flow Conditions
N/A
Year: 2000
Author(s): Almeida, M. C.
Editor: ******
Quebramares não-convencionais
|
|
Relatório Científico
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG G, e integra o Deliverable D3.3 do projeto. A EG G é responsável por 4 etapas dos sistemas urbanos de águas: i) captação e transporte, ii) transporte e distribuição de água, iv) recolha e transporte de águas residuais, v) tratamento e descarga. Os gastos com energia residuais têm nesta EG um peso significativo nos gastos totais, representando 8 % em 2018. A etapa de captação, transporte e distribuição de água foi a que consumiu em 2018 mais energia (65%), seguida da etapa de tratamento e descarga de águas residuais (31%) e da etapa de drenagem de águas residuais (4%). A EG G decidiu analisar a etapa de tratamento de águas residuais como crítica, não tendo sido efetuado o desempenho nas outras etapas. A etapa de tratamento de águas residuais não foi eficaz (qualidade da água não conforme com a licença de descarga); em eficiência energética, o desempenho foi bom em energia consumida por carga removida, mediano em energia consumida por volume tratado e insatisfatório em energia produzida. A etapa de tratamento de águas residuais foi dividida em 4 ETAR variando entre 0,5% na ETAR 4 e 12,3% na ETAR 1 Verificou-se que todas as ETAR tiveram desempenho insatisfatório em conformidade em 2018 e o consumo de energia por volume tratado mostra potencial de melhoria de eficiência energética. A ETAR 1 apresenta também maior potencial de produção de energia. Para a ETAR 1, que foi considerada uma das críticas, foram realizadas campanhas de medição de consumo de energia em cada processo da ETAR e o arejamento foi responsável pelo maior consumo de energia na ETAR 1, representando 3,2% do consumo de energia da EG G e com desempenho insatisfatório, em 2018. Os resultados alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Silva, C.; Loureiro, D.; Pisoeiro, J.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG H, e integra o Deliverable D3.3 do projeto. A EG H é responsável pelo abastecimento e drenagem em alta, tendo-se analisado apenas um sistema de tratamento e abastecimento de água e um sistema de drenagem e tratamento de água residual da EG H. Os gastos com energia para captação e transporte de água e drenagem e tratamento de água residual representam 37 % dos gastos totais em 2018 dos dois sistemas analisados. Os principais consumos de energia encontram-se na captação e transporte de água, representando 59 % do consumo total de energia na EG, e no tratamento de água residual, com 24 % do consumo total da EG H. A etapa de captação e transporte de água para consumo, relativamente à eficiência energética, revelou um nível insatisfatório em energia em excesso por volume de consumo autorizado e em consumo de energia normalizado das instalações elevatórias. Esta etapa de captação e transporte considerada crítica foi depois analisada para cada um dos 3 subsistemas de distribuição da EG H. Verificou-se que em 2018 o consumo energético de cada subsistema analisado variou entre 7 % e 39 % do consumo energético total da EG. O consumo de energia normalizado mostra potencial de melhoria em todos os subsistemas. Para o subsistema 3, que foi considerado o subsistema crítico, das 5 instalações elevatórias inseridas neste subsistema 3 apresentam um consumo de energia normalizado de nível mediano. Foram identificadas 3 instalações elevatórias críticas com um consumo energético que representa 37 % do consumo total da EG H. Os resultados agora alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Loureiro, D.; Silva, C.; Pisoeiro, J.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG I, e integra o Deliverable D3.3 do projeto. A EG I é responsável pela captação, transporte e distribuição de água e pela recolha de águas residuais. Esta EG, embora possua várias com captações próprias, adquire também água a EG em alta. Os gastos com energia para captação, transporte e distribuição de água e drenagem de águas residuais representam 4,4 % dos gastos totais em 2017. Este valor não contabiliza a energia gasta pela EG I indiretamente através da compra de água para consumo público e entrega de águas residuais para tratamento. O consumo de energia na captação, transporte e distribuição de água representou 96 % do consumo total de energia na EG, uma vez que a drenagem de água residual é maioritariamente gravítica. A etapa da captação, transporte e distribuição de água para consumo público revela um nível insatisfatório em perdas de água. Em eficiência energética, o desempenho foi mediano em energia em excesso por volume de consumo autorizado e em consumo de energia normalizada nas instalações elevatórias. Esta etapa foi depois analisada para cada um dos 9 subsistemas da EG I. Verificou-se que em 2017 o consumo de energia elétrica em cada subsistema analisado variou entre 0 % e 23 % do consumo energético total da EG. O consumo de energia normalizado das instalações elevatórias mostra potencial de melhoria em 8 dos 9 subsistemas. Para o subsistema 6 (Maceira), que foi considerado o subsistema crítico, o nível de perdas de água é elevado (50 %) e das 6 Instalações Elevatórias (IE) inseridas neste subsistema 3 têm rendimento insatisfatório e 3 têm rendimento mediano. Do total de IE do subsistema 6, 4IE foram identificadas como críticas por terem um desempenho mediano ou insatisfatório e por apresentarem um consumo energético relevante neste subsistema (13 % do consumo total da EG I). Os resultados agora alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Pisoeiro, J.; Loureiro, D.; Silva, C.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Substituir o resumo por: Neste documento apresenta-se os resultados do diagnóstico de eficiência energética nos serviços urbanos de águas na EG K participante no projeto, e integra o Deliverable D3.3 do projeto Avaler+. A EG K é responsável por 4 etapas dos sistemas urbanos de águas: i) captação e transporte, ii) transporte e distribuição de água, iv) recolha e transporte de águas residuais, v) tratamento e descarga. Os gastos com energia em 2017 tiveram um peso significativo (13%) nos gastos operacionais. A etapa de captação, transporte e distribuição de água foi a que consumiu mais energia (65,7%), tendo a etapa de tratamento e descarga de águas residuais e a etapa de drenagem de águas residuais consumido 27,8% e 6,5%, respetivamente. Na etapa de captação, transporte e distribuição de água, o equipamento de bombeamento apresentou globalmente um desempenho adequado, mas desempenho insatisfatório no Índice de energia fornecida (dE3). Entre os 4 subsistemas, o subsistema 3 (com 46% do consumo total) foi considerado crítico pelo desempenho insatisfatório da energia em excesso por consumo autorizado e da água não faturada. Os resultados indicam ineficiências de energia associadas a perdas de água e/ou layout, em vez de ineficiências da bomba. No entanto, dado o elevado consumo de energia elétrica no subsistema 3, as IE inseridas no subsistema crítico foram avaliadas no nível de análise 4. As IE 3.5, 3.7, 3.8 e 3.9 foram escolhidas para estudo dado o desempenho insatisfatório ou mediano no consumo normalizado e vida residual com valores insatisfatórios nas IE 3.8 e 3.9. Na etapa de tratamento de águas residuais, os resultados dos indicadores de eficiência energética mostraram desempenho mediano em termos de energia consumida por massa removida (wtE3) e bom desempenho por volume tratado (wtE2), mesmo com um valor significativo de 0,81 kWh /m3. As ETAR 5 e 9 (com 6% e 4% do total), foram identificadas como críticas, pois apresentam potencial de melhoria no consumo de energia por carga removida. Além disso, as ETARs 9 e 5 apresentaram maior consumo de energia para a mesma gama de volume tratado que outras ETAR (ETAR 9 vs. 8; ETAR 5 vs. 6). Na etapa de drenagem de águas residuais, o equipamento de bombeamento apresentou globalmente um desempenho mediano, desempenho mediano em Água residual recolhida e insatisfatório na Ocorrência de inundações. Os resultados alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Loureiro, D.; Silva, C.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG J, e integra o Deliverable D3.3 do projeto. A EG J é responsável por 4 etapas dos sistemas urbanos de águas: i) captação e transporte, ii) transporte e distribuição de água, iv) recolha e transporte de águas residuais, v) tratamento e descarga. Os gastos com energia para captação, transporte e distribuição de água e drenagem e tratamento de água residual representaram 10 % dos gastos totais em 2017. A etapa de captação, transporte e distribuição de água foi a que consumiu em 2017 mais energia (67%), seguida da etapa de tratamento e descarga de águas residuais (26%) e da etapa de drenagem de águas residuais (7%). Na etapa de recolha e transporte de águas residuais (que representou 7% do consumo total de energia na EG), o equipamento de bombeamento apresentou globalmente um desempenho mediano, e em termos de eficácia, o desempenho foi mediano em água residual recolhida (wcE6), em que o volume de água residual recolhida foi inferior ao volume de água residual faturada e insatisfatório na ocorrência de inundações (wcE7), indicando que existem oportunidades de melhoria, nomeadamente através de um maior controlo das inundações e de by-pass que podem estar a originar elevados volumes de descargas A etapa de captação, transporte e distribuição de água para consumo revela na eficiência energética um desempenho mediano no consumo de energia normalizado e na energia fornecida em excesso. A etapa de captação, transporte e distribuição de água foi divida em 3 subsistemas. Selecionou-se o subsistema 4, por representar 23% do consumo de energia na EG e por ser o que apresenta pior de desempenho em termos dos equipamentos de bombeamento, o valor mais elevado de energia fornecida em excesso e para o qual contribui maioritariamente a energia dissipada por perdas de água, para além da ineficiência nos equipamentos de bombeamento. Para o subsistema 4, que foi considerado o crítico, foram identificadas 3 instalações elevatórias para intervenção prioritária por representarem 8% consumo total da EG J e por apresentarem problemas de baixa eficiência associada a equipamentos envelhecidos e/ou degradados ou a funcionar afastados do ponto ótimo de operação. Na etapa de tratamento de águas residuais (que representou 26% do consumo total de energia na EG) os resultados dos indicadores de eficácia mostram 100% de conformidade no tratamento de águas residuais e os de eficiência energética mostram desempenho mediano em termos de energia consumida por volume tratado e bom desempenho por massa removida. Em relação à produção de energia o desempenho foi insatisfatório face ao potencial de produção. A etapa de tratamento de águas residuais foi dividida em 4 ETAR, mas a ETAR 1 foi responsável pela maioria do consumo no tratamento de águas residuais, correspondendo a 25% do consumo total da EG, onde se verificou que foi eficaz em 2017 e que existe potencial de melhoria de eficiência energética, quer no consumo de energia por volume tratado, quer na produção de energia. Para a ETAR 1, que foi considerada crítica, o arejamento foi responsável pelo maior consumo de energia, representando 14 % do consumo de energia da EG J e obteve um desempenho bom, no entanto pode ser insuficiente para satisfazer as necessidades da água residual a tratar. Os resultados agora alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Pisoeiro, J.; Silva, C.; Loureiro, D.; Rosa, M. J.
Keywords: Serviços urbanos de águas.; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG L, e integra o Deliverable D3.3 do projeto. A EG L é responsável pela captação, transporte e distribuição de água e pela recolha de águas residuais. Os gastos com energia para captação, transporte e distribuição de água e drenagem de águas residuais representam 6,2 % dos gastos totais em 2018. O consumo de energia na captação, transporte e distribuição de água representou 66 % do consumo total de energia na EG, com a etapa de drenagem de águas residuais e a etapa de tratamento de água a representarem 17 % cada uma. Relativamente à eficiência energética, a etapa da captação, transporte e distribuição de água para consumo público revelou um desempenho insatisfatório em energia em excesso por volume de consumo autorizado e mediano em consumo de energia normalizada nas instalações elevatórias. Esta etapa foi depois analisada para cada um dos 9 subsistemas da EG L. Verificou-se que em 2018 o consumo de energia elétrica em cada subsistema analisado variou entre 0 % e 28 % do consumo energético total da EG. O consumo de energia normalizado das instalações elevatórias mostra potencial de melhoria em todos os subsistemas, com diagnóstico insatisfatório e mediano. Para os subsistemas 2 e 3, que foram considerados críticos, das 4 Instalações Elevatórias (IE) inseridas nestes subsistemas 2 têm rendimento insatisfatório e 2 têm rendimento mediano. As identificadas como criticas foram a IE 2.1, por apresentar um desempenho insatisfatório no rendimento e consumo normalizado e por representar 15 % do consumo total da EG L, e a IE 3.1, por apresentar diagnóstico insatisfatório nos mesmos indicadores combinado com uma vida residual de apenas 0,16. Os resultados agora alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Loureiro, D.; Pisoeiro, J.; Silva, C.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Plano de ação
Neste documento apresentam-se os resultados do diagnóstico de eficiência energética numa das 13 entidades gestoras (EG) de serviços urbanos de águas participantes no projeto Avaler+, a EG M, e integra o Deliverable D3.3 do projeto. A EG M é responsável pela captação, transporte e distribuição de água e pela recolha de águas residuais. Os gastos com energia para captação, transporte e distribuição de água e drenagem de águas residuais representam 9,4 % dos gastos totais em 2017. O consumo de energia na captação, transporte e distribuição de água representou 94 % do consumo total de energia na EG, uma vez que a drenagem de água residual é maioritariamente gravítica. O desempenho energético foi mediano em energia em excesso por volume de consumo autorizado e insatisfatório em consumo de energia normalizada nas instalações elevatórias. Esta etapa foi depois analisada para cada um dos 7 subsistemas da EG M. Verificou-se que em 2017 o consumo de energia elétrica em cada subsistema analisado variou entre 0 % e 30 % do consumo energético total da EG. O consumo de energia normalizado das instalações elevatórias mostra potencial de melhoria em 5 dos 7 subsistemas. Para os subsistemas 4 e 5, que foram considerados críticos, das 4 Instalações Elevatórias (IE) inseridas nestes subsistemas 3 têm rendimento insatisfatório e 1 tem rendimento mediano. A IE 4.1 foi identificada como crítica por apresentar um desempenho insatisfatório e por representar praticamente a totalidade do consumo energético neste subsistema (18 % do consumo total da EG M). Os resultados agora alcançados no diagnóstico (Tarefa 3) constituem a base para o estudo de alternativas (Tarefa 4).
Year: 2020
Author(s): Loureiro, D.; Pisoeiro, J.; Silva, C.; Rosa, M. J.
Keywords: Serviços urbanos de águas; Diagnóstico; Plano de ação; Eficiência energética; Avaliação de desempenho
Info
Report on cost-benefit analysis
This document presents relevant indicators that may affect the impact of LIFE IMPETUS project actions, as well the results of a Future Scenarios Design exercise, in order to address a sustained approach to their potential.
Year: 2020
Author(s): Ribeiro, R.; Viegas, R.M. C.; Rosa, M. J.
Keywords: Benefits; Costs; Cost-benefit analysis
Info
Report on LIFE IMPETUS International Final Conference
This document summarises the LIFE IMPETUS Final Conference held in Lisbon on 5 December 2019.
Year: 2020
Author(s): Ribeiro, R.; Rosa, M. J.
Keywords: LIFE IMPETUS Final Conference
Info
Report on PAC testing at full scale in FNW WWTP
This document constitutes a Technical report of Action B7.2
Year: 2020
Author(s): Campinas, M.; Viegas, R.M. C.; Silva, C.; Gomes, A.; Rosa, M. J.
Keywords: Efficiency; Energy; Pharmaceutical compounds; Biological reactor; Full scale; Activated carbon; PAC testing; Secondary treatment; WWTP; Faro NW; Wastewater treatment; LIFE Impetus
|
|
|
Outro
Info
AWARE-P vence prémio alemão e conquista novo reconhecimento internacional
EXCLUSIVO: AWARE-P vence prémio alemão e conquista novo reconhecimento internacional: É a primeira vez que é distinguido um projecto de um país que não fala alemão, entrevista de Ana Santiago (Jornalista do Jornal Água & Ambiente - Portal Ambiente Online) a Helena Alegre, 19 de Agosto de 2014
Year: 2014
Number Pages:
1.
Author(s): Alegre, H.
Info
Processos de pré oxidação e de desinfeção
N/A
Year: 2014
Number Pages:
36 slides.
Author(s): Rosa, M. J.
Editor: APDA
Info
Vamos premiar quem aproveitou melhor a tecnologia
N/A
Year: 2014
Number Pages:
1p.
Author(s): Alegre, H.
Editor: Ambiente on-line
Info
Ciência e inovação
N/A
Year: 2012
Number Pages:
1p.
Author(s): Alegre, H.
Editor: About Media
Info
A engenharia sanitária no DHA em 2023
N/A
Year: 2009
Author(s): Alegre, H.
Info
Aplicações do modelo SWMM a casos de Estudo.
N/A
Year: 2009
Author(s): Brito, R. S.; David, L. M.
Info
Modelação dinâmica de sistemas de drenagem: Casos de estudo nacionais
N/A
Year: 2009
Author(s): Ferreira, F.; David, L. M.; Brito, R. S.
Info
Modelação dinâmica de sistemas de drenagem: Princípios de modelação e principais modelos existentes
N/A
Year: 2009
Author(s): Ferreira, F.; David, L. M.; Matos, J. S.
Info
Modelação estatística do consumo nocturno doméstico de água
N/A
Year: 2009
Author(s): Borba, R.; Amado, C.; Pacheco, A.; Loureiro, D.; Rebelo, M.; Alegre, H.; Coelho, S. T.; Covas, D.; Pina, A.
Info
O tratamento de água para consumo humano face à qualidade da água de origem
N/A
Year: 2009
Author(s): Rosa, M. J.; Vieira, P.; Menaia, J.
|