Papers
Info
Direct displacement-based design for RC structures
In the early nineties, the Performance-Based Seismic Engineering (PBSE) principles have been introduced in the seismic design of structures. Several authors have identified the limitations of traditional force-based design (FBD) procedures widespread in most of the design codes to accomplish the PBSE requirements. Therefore, various contributions were made towards the development of displacement-based seismic design methodologies, in particularly the one proposed by Priestley, known as "Direct Displacement-Based Design" (DDBD). The purpose of this work is to investigate the DDBD approach in its entirety. In particular, the emphasis is set herein on the definition of the equivalent viscous damping and on the concrete impact of choosing one or another expression. Then, the efficiency of applying DDBD to reinforced concrete (RC) plane frames and dual frame-wall structures is assessed and the consequences of using the linear response spectrum suggested in the Eurocode 8 as input data is investigated.
Year: 2018
Number Pages:
67-88pp.
Author(s): Massena, B.; Degée, H.; Candeias, P.; Bento, R.
: Revista Portuguesa de Engenharia de Estruturas (rpee)
Editor: LNEC
Volume:
Série III, N.º 6.
Keywords: Reinforced concrete buildings; Equivalent viscous damping; Direct displacement-based design
Info
Influência do número de sheds e da distância horizontal entre eles no desempenho da ventilação natural
A ventilação natural é uma eficiente estratégia para o condicionamento térmico passivo de edificações, e muitas vezes o seu potencial está relacionado às decisões em projeto diferentes do modelo convencional. Um exemplo são os sheds, aberturas na cobertura que funcionam como captadores ou extratores de ar, dependendo de sua localização em relação aos ventos dominantes. O objetivo do artigo é avaliar a influência do número de sheds e da distância entre eles no desempenho da ventilação natural. Os ângulos de incidência dos ventos analisados foram 0º, 45º, 135º e 180º. A metodologia adotada foi simulação por Dinâmica dos Fluidos Computacional (CFD), utilizando o software CFX. Os resultados indicam que o aumento do número de sheds reduz a renovação de ar interna para as situações de extração e captação de ar. Por outro lado, o aumento da distância entre esses dispositivos, incrementa o fluxo de ar interno para os sheds captadores. No entanto, teve-se uma redução na renovação de ar para os sheds extratores de ar. Isso ocorre pela redução da área total das abertiras de saída de ar, que apresenta uma influência na vazão volumétrica do edifício. Nos sheds captadores de ar o incremento ocorre, pois, apesar do aumento da distância ter reduzido o número das aberturas de entrada de ar, torna os sheds mais efetivos para captar o fluxo de ar.
Year: 2018
Number Pages:
161-176pp.
Author(s): Lukiantchuki, M.; Shimomura, A.; Marques da Silva, F.; Caram, R.
: Ambiente Construído
Editor: ANTAC (Associação Nacional de Tecnologia do Ambiente Construído)
Volume:
vol.18 no.2.
Keywords: Ventilação Natural; CFD
Info
Seismic vulnerability assessment of a RC pedestrian crossing
The paper addresses the seismic vulnerability assessment of a multispan footbridge, prone to span unseating due to shorter seat lengths. The structure is representative of a series of pedestrian crossings located in the Southern part of Portugal, a region with a relevant seismicity. A probabilistic approach allows considering the variability of the seismic action and uncertainties in the definition of the material properties and/or structural behavior. Based on incremental dynamic analyses and corresponding fragility curves, it is shown that, for code compliance design acceleration, there is a significant probability that the structure will only suffer minor damage.
Year: 2018
Number Pages:
18p.
Author(s): Cismasiu, C.; Santos, F.; Perdigão, R.; Bernardo, V.; Candeias, P.; Carvalho, A. M.; Guerreiro, L.
: Journal of Earthquake Engineering
Editor: Taylor & Francis
Keywords: Dowel connection; Fragility curves; Incremental dynamic analysis; Operational modal analysis; Seismic vulnerability assessment; Rc footbridges
Info
Seismic vulnerability assessment of a RC pedestrian crossing
The paper addresses the seismic vulnerability assessment of a multi-span footbridge, prone to span unseating due to shorter seat lengths. The structure is representative of a series of pedestrian crossings located in the Southern part of Portugal, a region with a relevant seismicity. A probabilistic approach allows considering the variability of the seismic action and uncertainties in the definition of the material properties and/or structural behavior. Based on incremental dynamic analyses and corresponding fragility curves, it is shown that, for code compliance design acceleration, there is a significant probability that the structure will only suffer minor damage.
Year: 2018
Number Pages:
18p.
Author(s): Cismasiu, C.; Santos, F.; Bernardo, V.; Candeias, P.; Carvalho, A. M.; Guerreiro, L.; Perdigão, Rui A. Silva
: Journal of Earthquake Engineering
Editor: Taylor & Francis
Keywords: Dowel connection; Fragility curves; Incremental dynamic analysis; Operational modal analysis; Seismic vulnerability assessment; Rc footbridges
Info
Shake table blind prediction tests: Contributions for improved fiber-based frame modelling
Distributed plasticity Euler-Bernoulli fiber beams are regularly used byresearchers and practitioners to simulate the nonlinear seismic responseof reinforced concrete framed structures. This study presents a sensitivityanalysis, combining newly proposed and existing goodness-of-fitmeasures, to identify commonly used engineering modeling optionsthat most critically influence the response accuracy. The dynamic behaviorof three distinct structures tested in international blind predictionchallenges is considered. Sensitivity parameters include equivalent viscousdamping, element formulation, strain penetration effects, andmaterial models. The results are critically discussed in light of theoreticalshortcomings of the model assumptions.
Year: 2018
Number Pages:
42p.
Author(s): Sousa, R.; Almeida, J.P.; Correia, A.A.; Pinho, R.
: Journal of Earthquake Engineering
Editor: Taylor & Francis
Keywords: Material models; Strain penetration; Equivalent viscous damping; Fiber element formulation; Sensitivity analysis; Reinforced concrete frames; Shake table tests; Numerical validation
Info
Simulation and measurements of wind interference on a solar chimney performance
The solar chimney is a stack-induced ventilation strategy used to improve thermal performance in buildings. Besides operating via a buoyancy-driven airflow, even low velocity winds can affect the chimney functioning in both positive and negative ways. In technical literature, though, few studies have considered the influence of windspeed and direction, as well as discharge coefficients and wind pressure coefficients. This paper investigates the effects of wind interference on a solar chimney performance, through different scenarios of wind speed and direction, over a base case model. Wind tunnel experiments and computer simulations using EnergyPlus were carried out to perform qualitative and quantitative analyses of the airflow, as a function of the combined effect of thermal and wind components. Results showed that the airflow rate and distribution pattern at the outlet openings of the solar chimney are influenced by either the thermal gradients and, mainly, by the outdoor windvelocity and direction. A significant reduction in the volumetric flow rate of the chimney is observed due to wind incidence opposite to the inlet opening, even at low velocities, such as 0.6 m/s.
Year: 2018
Number Pages:
135-145pp.
Author(s): Neves, L.; Marques da Silva, F.
: Journal of wind engineering and industrial aerodynamics
Editor: Elsevier
Volume:
179.
Keywords: Wind tunnel; Buoyancy; Solar chemney
Info
Caracterização do comportamento sísmico de edifícios de betão armado representativos do edificado português sem dimensionamento sismorresistente
Uma parte significativa do edificado em Portugal não foi dimensionada para resistir a ações sísmicas. Como tal, o recente impulso do sector da reabilitação pode representar uma oportunidade única para promover a redução da vulnerabilidade sísmica dos edifícios existentes. Neste contexto, o presente trabalho apresenta uma metodologia para avaliar a vulnerabilidade sísmica duma classe de edifícios de betão armado que permite estabelecer indicadores simplificados do seu desempenho estrutural expectável. A metodologia proposta baseia-se num estudo numérico detalhado do comportamento sísmico de edifícios de betão armado com características representativas duma parte significativa do edificado deste tipo em Portugal, simulando de forma adequada os principais aspetos da sua resposta estrutural. Os resultados obtidos pela metodologia desenvolvida permitem identificar as principais vulnerabilidades do edificado e quantificar indicadores de desempenho estrutural que permitem avaliar de forma expedita a sua segurança estrutural.
Year: 2017
Number Pages:
105-114pp.
Author(s): Sousa, R.; Costa, A.; Campos Costa, A.; Candeias, P.; Romão, X.
: RPEE
Editor: LNEC
Volume:
Série III, N.º 3.
Keywords: Indicador de desempenho estrutural; Comportamento sísmico; Betão armado; Reabilitação
Info
Carga aerodinâmica em sombreamentos em cascata
A arquitetura recorre, por vezes, a dispositivos de sombreamento de grandes dimensões, com formas e configurações de montagem cuja resposta à ação do vento carece de caracterização. Este facto condiciona o correto dimensionamento dos apoios e, em menor escala, a determinação do próprio material de construção dos dispositivos.As dimensões dos elementos constituintes destes dispositivos dificultam o recurso a ensaios com modelos reduzidos pelo que se recorreu a um modelo seccional do dispositivo à escala real, sujeito ao escoamento proveniente de um túnel de vento de jacto livre. As características específicas deste ensaio, nomeadamente a geometria do perfil de sombreamento e respetivos suportes, gama de forças e a necessidade de minimizar a obstrução adicionada pela instrumentação ao escoamento, ditaram o desenvolvimento de uma solução particular para a medição das forças aerodinâmicas.O ensaio permitiu avaliar as cargas induzidas pelo escoamento para vários ângulos de incidência fazendo variar a inclinação do modelo relativamente ao jacto através de um suporte articulado onde se montou o modelo seccional, permitindo assim caracterizar o desempenho aerodinâmico do perfil na aplicação em estudo.
Year: 2017
Number Pages:
8p.
Author(s): Marques da Silva, F.; Morais, P.; Pereira, I.; Bairrão, R.; Morais, J.
: Mecânica Experimental
Editor: APAET
Volume:
nº 29.
Keywords: Cascatas; Ação do vento
Info
Shape memory alloy based dampers for earthquake response mitigation
This paper describes the development process and initial tests performed with a new energy dissipation damper based on Shape Memory Alloy (SMA) wires. The aim of this study was to develop a new iteration of this type of devices, and eventually develop a methodology to properly design them for any type of application. The underlying concept of our device is the use of a double counteracting system of pre-strained SMA wire sections as the dissipating component. By using pre-strained wires, this design focuses on maximizing energy dissipation, partially relinquishing the re-centering capabilities of the device.The experimental part was performed on a downscaled prototype based on this design methodology. The goal of this study was to validate the basic mechanical concepts. The device was subjected to a considerable number of load cycling tests, in order to better characterize the SMA wire behavior when used in this arrangement and to improve our understanding of their influence on the device's capabilities.
Year: 2017
Number Pages:
705-712pp.
Author(s): Morais, J.; Gil de Morais, P.; Santos, C.; Campos Costa, A.; Candeias, P.
: Procedia Structural Integrity
Editor: Elsevier
Volume:
Vol. 5.
Keywords: Earthquake Response; Shape Memory Alloy; Vibration Damper
Info
Application of SASHA to seismic hazard for Portugal mainland.
In the frame of the UPStrat-MAFA
Year: 2016
Number Pages:
1827
Author(s): Carvalho, A. M.; Albarello, D.
: Bulletin of Earthquake Engineering
Editor: Springer
Volume:
Volume 14, Issue 7.
Keywords: Portugal; Macroseismic intensity; Seismic hazard
|
Comunicação
Info
Shaking table tests on thin lightly reinforced H-shaped structural walls
The paper presents an experimental program on a 5 storey structural wall physical model performed in LNEC 3D shaking table, in Lisbon, within the Project ECOLEADER-LIS. The characteristics of the reduced model and the test set-up are described, as well as the analysis of the main experimental results. Furthermore the results of numerical simulations are discussed. These tests had the main purpose of studying and evaluating the seismic resistance of thin lightly reinforced structural walls representative of the Central Europe practice. Particular issues have been adressed: (a) To investigate the influence of simultaneous 3D loading conditions. (b) To study walls with T (H) cross-sections. (c) To investigate the free edge of a T (H) shaped walls in compression and different trypes of confinement. (d) To investigate the behaviour of coupled walls and the behaviour of diagonally reinforced coupling beams in thin walls. (e) To calibrate and further develop numerical models. Inelastic dynamic analysis was also performed using Multiple-Vertical-Line-Element-Model (MVLEM), which was extended into 3D and implemented into OpenSees. This macro model proved the ability to simulate and predict the global behavior of the wall as well as the behavior of confined boundary areas and local extensions of longitudinal reinforcement. Considerable overstrength was observed in the wall with minimum reinforcement. However, its deformation capacity was limited to less than 1% of the height. Relatively thick slab enhanced the strength of thin coupling beams considerably. Consequently, they did not perform as expected in capacity design and high axial forces as well as shear failure were induced into the wall piers. The EC8 confining reinforcement proved to be efficient. Simpler details (i.e. U-shaped stirrups) might be acceptable for low walls (5-storey) and/or in the case of low seismic intensity. Sequence of loading and pre-cracking influenced the response considerably. The influence of bi-axial loading was relatively low.
Year: 2006
Number Pages:
10p.
Author(s): Coelho, E.; Campos Costa, A.; Falcão Silva, M. J.; Fischinger, M.
Editor: Swiss Society for Earthquake Engineering and Structural Dynamics ( SGEB )
Keywords: Reinforced concrete; Shaking table
Info
Vibration based damage identification of masonry structures
In the process of preservation of ancient masonry structures, damage evaluation and monitoring procedures are particularly attractive, due to the modern context of minimum repair and observational methods, with iterative and step-by-step approaches. High-priority research issues related to damage assessment and monitoring are global non-contact inspection techniques, sensor technology, data management, diagnostics (decision making and simulation), dynamic (modal) analysis, self-diagnosing / self-healing materials, and prediction of early degradation. On these concerns, the present paper aims to assess damage in masonry structures at an early stage. Replicates of historical constructions were built in virgin state. Afterwards, progressive damage was applied and modal identification analysis was performed at each damage stage, aiming at finding adequate correspondence between dynamic behavior and internal crack growth. Accelerations and dynamic strains were recorded in many points of the replicates. Comparisons between different techniques based on vibrations measurements are made to evaluate different damage identification methods.
Year: 2006
Number Pages:
10p.
Author(s): Ramos, L.F.; Lourenço, P.; Campos Costa, A.; De Roeck, G.
Editor: Macmillan
Keywords: Masonry constructions; Dynamic (modal) analysis
Info
A finite
This work uses a non-stationary stochastic seismological model, based on random vibration theory, for calculating response spectra and synthesizing strong ground motion acceleration records for Portugal Mainland. The validation of the method and comparison with strong ground motion records for Portugal are entirely carried out in terms of 5% damped pseudo absolute response spectra for acceleration. The calibrated model is used to simulate ground motion acceleration for the 1755 Lisbon earthquake. Five potential source rupture models that have been recently proposed by several authors for the 1755 Lisbon earthquake are tested: two analytical models based on hydrodynamic studies; two models based on seismic surveys and on from a recent suggestion based on induced stress changes.For all models, peak ground acceleration maps are compared with iso-intensities map of the earthquake in order to test the ability of the source models for estimating the intensities of the earthquake. The peak ground motion is calculated for different unknown parameters like the rupture velocity, the slip distribution and the nucleation point. The fault parameters like dimension, dip and strike are the ones proposed by the authors of the different analysed source models
Year: 2005
Number Pages:
578-583pp.
Author(s): Carvalho, A. M.; Campos Costa, A.; Oliveira, C.S.
: 250th Anniversary of the I755 Lisbon Earthquake: proceedings
Editor: LNEC
Keywords: Non-stationary stochastic seismological model
Info
Operational modal analysis for damage detection of a masonry construction
This paper presents a dynamic identification analysis of a masonry construction, built to be tested in
Year: 2005
Number Pages:
495-502pp.
Author(s): Ramos, L.; Campos Costa, A.; Lourenço, P.
: Proceedings of the 1st International Operational Modal Analysis Conference: IOMAC
Editor: Aalborg University
Keywords: Rubble stone; Masonry construction
Info
Simulating earthquake scenarios using finite-fault model for The Metropolitan Area of Lisbon (MAL)
In the framework of the ongoing European project
Year: 2005
Number Pages:
164-171pp.
Author(s): Zonno , G.; Carvalho, A. M.; Franceschina, G.; Campos Costa, A.; Coelho, E.; Cultrera, G.; Pacor, F.; Pessina, V.; Cocco, M.; Akinci, A.
: 250th Anniversary of the I755 Lisbon Earthquake: proceedings
Editor: LNEC
Keywords: Seismic risk scenario
Info
Verificación experimental da formulación compleja del rocking motion
En este trabajo se confirma experimentalmente una nueva formulación del problema de los bloques rígidos sometidos a vibraciones externas. Un estudio sistemático de las respuestas del sistema permite determinar los valores de los parámetros relevantes. La nueva formulación hace más sencilla la implementación de técnicas computacionales para el problema da varios tipos de mecanismos acoplados. En las respuestas analizadas, tanto para régimen libre como forzado, se ha observado un buen acuerdo entre teoría y experimento.
Year: 2005
Number Pages:
13p.
Author(s): Prieto, F.; Lourenço, P.; Campos Costa, A.
Editor: SEMNI
Keywords: Construcciones históricas; Rocking motion; Terramotos; Experimental
Info
A stochastic finite
This work presents a non-stationary stochastic seismological model, based on random vibration theory. The model is applied to the 1755 Lisbon earthquake, being a tentative of reproducing the input motion of this severe earthquake. Five possible interpretations of the fault source mechanism, recently proposed by several authors for the 1755 Lisbon earthquake, are analyzed. Three interpretations are based on seismic surveys and two from a suggestion based on induced stress changes. In order to test the feasibility of the different proposed fault source mechanisms to reproduce the historical intensities of the earthquake, ground motion maps were obtained at bedrock level and the degree of the interrelationship between some seismic parameters and the intensities of the earthquake aredescribed by a correlation analysis.
Year: 2004
Number Pages:
15p.
Author(s): Carvalho, A. M.; Campos Costa, A.; Oliveira, C.S.
Editor: 13WCEE Secretariat
Keywords: 1755 Lisbon earthquake
Info
An automatic seismic scenario loss methodology integrated on a geographic information system
The objective of the present paper is to present the new LNEC automatic Seismic Scenario Loss estimate methodology (SSL), integrated on a Geographic Information System (GIS), which comprises modules evaluating bedrock seismic input, local soil effects, vulnerability and fragility analysis and human losses analysis.Results of seismic risk scenarios studies for the Metropolitan Area of Lisbon are presented.
Year: 2004
Number Pages:
13p.
Author(s): Luísa Sousa, M.; Campos Costa, A.; Carvalho, A. M.; Coelho, E.
Editor: 13WCEE Secretariat
Keywords: Seismic scenario loss
Info
Análise experimental para obtenção das características dinâmicas do edifício da Portugal Telecom no Parque das Nações
Este trabalho foi realizado no âmbito do projeto Dynaseis POCTI 36071-2000, cujos objetivos principais são: i) a determinação experimental de frequências próprias e modos de vibração de uma estrutura em betão armado localizada no Parque das Nações em Lisboa; ii) a elaboração do modelo numérico da estrutura e a sua comparação com os resultados experimentais; iii) a avaliação do comportamento da estrutura sob ação sísmica. Neste estudo apresentam-se os resultados dos ensaios experimentais e a comparação com o modelo numérico de elementos finitos (FEM). O edifício escolhido foi a torre da Portugal Telecom
Year: 2004
Number Pages:
565-574pp.
Author(s): Baptista, M.A.; Mendes, P.; Campos Costa, A.; Afilhado, A.; Silva, P.; Oliveira, C.S.
Editor: Universidade do Minho
Keywords: Calibração de modelos numéricos; Ensaios de vibração ambiental; Características dinâmicas
Info
Caracterização do comportamento dinâmico de barragens de betão com base em ensaios de vibrações ambiente e modelos numéricos
Neste trabalho apresentam-se resultados com os quais se pretende mostrar que atualmente já é possível caracterizar o comportamento dinâmico de grandes barragens de betão (frequências próprias e modos de vibração) com base na medição das vibrações ambiente, ou induzidas pelas atividades de exploração. Para tal é importante utilizar instrumentação adequada e uma estratégia de análise e interpretação das medições baseada na utilização conjunta de diferentes metodologias de identificação modal e de resultados de modelos numéricos que permitam simular o comportamento dinâmico do sistema barragem-fundação-albufeira. Este objetivo só pode ser conseguido com uma monitorização em contínuo, a qual permitirá também obter a resposta da estrutura a eventuais ações sísmicas
Year: 2004
Number Pages:
10p.
Author(s): Mendes, P.; Oliveira, S.; Guerreiro, L.; Baptista, M.A.; Rodrigues, J.; Campos Costa, A.
Editor: Universidade do Minho
Keywords: Comportamento dinâmico; Barragens de betão
|
Books
Info
Historical earthquake-resistant timber framing in the mediterranean area
This book presents a selection of the best papers from the HEaRT 2015 conference, held in Lisbon, Portugal, which provided a valuable forum for engineers and architects, researchers and educators to exchange views and findings concerning the technological history, construction features and seismic behavior of historical timber-framed walls in the Mediterranean countries. The topics covered are wide ranging and include historical aspects and examples of the use of timber-framed construction systems in response to earthquakes, such as the gaiola system in Portugal and the Bourbon system in southern Italy; interpretation of the response of timber-framed walls to seismic actions based on calculations and experimental tests; assessment of the effectiveness of repair and strengthening techniques, e.g., using aramid fiber wires or sheets; and modelling analyses. In addition, on the basis of case studies, a methodology is presented that is applicable to diagnosis, strengthening and improvement of seismic performance and is compatible with modern theoretical principles and conservation criteria. It is hoped that, by contributing to the knowledge of this construction technique, the book will help to promote conservation of this important component of Europe
Year: 2016
Number Pages:
468p.
Author(s): Cruz, H.; Saporiti Machado, J.; Campos Costa, A.; Candeias, P.; Catarino, J. M.
Editor: Springer
Volume:
Vol. 1.
Keywords: Heart 2015 Conference; Historic Masonry; Performance-based Assessment; Structural Health Monitoring; Timber-Framed Construction Systems; Seismic-Resistant Timber Frames; Historical Constructive Analysis; Historical Timber-Framed Walls
Info
Assessment of the seismic capacity of stone masonry walls with block models
The applications of discrete elements models based on rigid block formulations to the analysis of masonry walls under horizontal out-of-plane loading is simplified block pattern are addressed. Two procedures for creating irregular block systems are presented, one using Voronoi polygons, the other based on a bed and cross joint structure with random deviations. A test problem provides a comparison of various regular and random block patterns, showing their influence on the failure loads. The estimation of manual frequencies of rigid block models, and its application to static pushover analyses, is addressed. An example of application of rigid block model to wall capacity problem is presented.
Year: 2011
Number Pages:
221-236pp.
Author(s): Lemos, J. V.; Campos Costa, A.; Bretas, E. M.
: Computational Methods in Earthquake Engineering
Editor: Springer
Volume:
Vol. 21.
Keywords: RTigid blocks; Discrete elements; Seismic assessment; Masonry structures
Info
Earthquake disaster scenario prediction and loss modelling for urban areas
The overall aim of Sub-Project 10 (Earthquake disaster scenario predictions and loss modelling for urban areas) has been to create a tool, based on state-of-the-art loss modelling software, to provide strong, quantified statements about the benefits of a range of possible mitigation actions, in order to support decision-making by urban authorities for seismic risk mitigation strategies. A further larger aim has been to contribute to a seismic risk mitigation policy for future implementation at European level. Among the European cities for which loss estimation studies have been carried out are Istanbul, Lisbon and Thessaloniki, and tools, using GIS mapping, have been developed by research teams in each of these cities; these were made available for further development to examine mitigation strategies within SP10. Related research studies
Year: 2007
Number Pages:
180p.
Author(s): Campos Costa, A.; Carvalho, A. M.
Editor: IUSS Press
Keywords: Shaking scenarios
Info
European manual for in-situ assessment of important existing structures. LessLoss Sub Project 5-In-situ assessment, monitoring and typification of buildings and infrastructure
Much work in Earthquake Engineering was devoted to the improvement of earthquake resistant design of new structures. One European result is EN 1998, which will be in several years the main seismic code for all European countries. But it is well known, that older existing structures cause in many large earthquakes much more casualties and damages than new structures. It is certainly not possible to retrofit all existing structures, but agreement exists, that assessment and retrofit of safety - critical - structures and lifeline structures must have priority. In September 2004 the European Integrated Research Project LESSLOSS on Risk Mitigation for Earthquakes and Landslides was started. The project will run for three years and comprises 13 Sub-Projects (SP´s). The consortium consists of 46 partners (see http:\\www.lessloss.org). LESSLOSS SP5 is on In-situ Assessment, Monitoring and Typification of buildings and Infrastructure. The project partners of SP5 are ARS, CESI, LNEC, RWTH and VCE. This Sub Project focuses mainly on the assessment of important existing structures and tries to integrate experimental methods into the assessment procedure. The progress of SP5 obtained in the first year is summarized in this paper. Highlights presented by all partners are mentioned and the assessment of Hospital Innsbruck is presented in more detail. The most innovative task of LESSLOSS/ SP5 is Update of vulnerability estimates via monitoring, which was also started in the first year.
Year: 2007
Number Pages:
195p.
Author(s): Campos Costa, A.; Candeias, P.; Mendes, L.; Flesch, R.; Pellegrini, R.; Friedl, H.; Hoffmeister, B.; Oppe, M.; Veit-Egerer, R.; Wenzel, H.; Eusebio, M.
Editor: IUSS Press
Keywords: Structures; Earthquake
Info
Modal analysis from ambient vibration survey of bridges: LNEC experience
In order to study the behavior of bridge structures in relation to traffic, wind and seismic loads, it is extremely important to know their actual dynamic properties (natural frequencies, vibration mode shapes and damping). The experimentally identified dynamic properties of bridge structures are also an effective way to characterize their actual global structural behavior. Whether included in the reception load tests of recently built bridges, before they are opened to the traffic, or as part of the inspection works of bridges already in service, LNEC has performed modal analysis studies based on the results of ambient vibration tests. Some of the studies carried out recently in important bridges are reported in this paper.
Year: 1999
Number Pages:
712-718pp.
Author(s): Rodrigues, J.; Campos Costa, A.
: Proceedings of the 17th International Modal Analysis Conference : February 8 - 11, 1999 / IMAC XVII.
Editor: SEM
Volume:
Vol. 3727.
Keywords: Dynamic properties; Bridge structures
Info
O Sismo de Northridge, Los Angeles, de 17 Janeiro de 1994. Ensinamentos para Portugal.
O sismo de Northridge ocorreu na parte norte da área metropolitana de Los Angeles, Califórnia, às 4:31 h do dia 17 de janeiro, uma segunda-feira coincidente com dia de feriado nacional, tendo atingindo uma magnitude de 6.6 na escala de Richter. O número total de vítimas mortais cifra-se em 57, havendo para cima de 8 000 feridos e 20 000 desalojados.As estimativas de perdas totais, feitas em meados de fevereiro de 1994, apontavam para valores de 15 biliões de US dólares, tendo o Estado da Califórnia apresentado um impacto económico total de ordem dos 30 biliões de dólares, perto do valor do Orçamento Geral do estado Português para 1994. Os prejuízos infligidos na indústria e no comércio são também surpreendentemente elevados, exigindo longos períodos de interrupção das atividades económicas.
Year: 1995
Number Pages:
165p.
Author(s): Oliveira, C.S.; Costa, A.; Campos Costa, A.; Azevedo, J.; Delgado, R.M.
Editor: IST e FEUP
Keywords: Northridge earthquake; Earthquake effects
|
Capítulo de Livro
Info
Shaping favorable beliefs towards seismic protection through risk communication: A pilot-experience in two Lisbon schools (Portugal).
Communicating science within disaster risk reduction using methods that encourage two-way dialogue between scientists and laypersons is a challenging task. This paper aims at presenting a methodological strategy of communicating risk and non-structural seismic protection measures through participatory approach. Such methodological strategy is part of a pilot experience of risk communication in two schools in Lisbon (Portugal) under the EU project KnowRISK (Know your city, Reduce seISmic risK through non-structural elements). The efficacy of education for seismic safety is often inhibited by an incomplete understanding of the process by which individuals decide to protect themselves from harm (Becker JS, Paton D,Johnston DM, Ronan KR. Nat Hazards 64(1):107
Year: 2019
Number Pages:
445-458pp.
Author(s): Silva, D. S.; Vicente, M.; Pereira, A.; Candeias, P.; Ferreira, M.A.; Oliveira, C.S.; Bernardo, R.; Lopes, M.; Henriques, P.
: Proceedings of the International Conference on Earthquake Engineering and Structural Dynamics
Editor: Springer Link
Volume:
Volume 47.
Keywords: Non-structural; Protective behaviours; Risk communication; Seismic risk
Info
Characterization of timber masonry walls with dynamic tests
Most of the Lisbon 18th century timber-framed masonry
Year: 2018
Number Pages:
299-309pp.
Author(s): Gonçalves, A.; Candeias, P.; Guerreiro, L.; Ferreira, J.; Campos Costa, A.
: Historical earthquake-resistant timber framing in the mediterranean area
Editor: Springer
Volume:
Vol. 1.
Keywords: Shaking table tests; Timber-masonry walls;
Info
KnowRISK practical guide for mitigation of seismic risk due to non-structural components
Good performance of non-structural elements can be decisive in saving lives and costs when an earthquake strikes. The European project KnowRISK aims to educate and encourage households to take the necessary precautionary measures to protect people, houses, and contents. Preparedness and prevention act on community resilience. Within the KnowRISK project, the idea of a Practical Guide has been conceived suggesting seismic mitigation solutions for non-structural components to non-experts stakeholders. It is intended to guide people into the first steps of prevention in a straightforward manner, minimizing or avoiding injuries, damage, and long-term financial consequences. The novelty of the Guide belongs to his philosophy: a path through increasing challenges corresponds to a growing level of safety. The idea is that anyone can mitigate seismic risk in its own environment by adopting simple and low cost measures. The Practical Guide may contribute to increase risk awareness. This kind of initiatives if undertaken at larger scales may also enhance social resilience.
Year: 2018
Number Pages:
309-321pp.
Author(s): Ferreira, M.A.; Oliveira, C.S.; Lopes, M.; Musacchio, G; Candeias, P.; Vicente, M.; Silva, D. S.; O
: Proceedings of the International Conference on Earthquake Engineering and Structural Dynamics
Editor: Springer Link
Volume:
Volume 47.
Keywords: Practical guide; Community resilience; Preparedness; Non-structural elements
Info
Elastic and inelastic analyses of frames with a force-based higher-order 3D beam element accounting for axial-flexural-sheartorsional interaction
When one of the dimensions of a structural member is not clearly larger than the two orthogonal ones, engineers are usually compelled to simulate it with refined meshes of shell or solid finite elements that typically impose a large computational burden. The alternative use of classical beam theories, either based on Euler-Bernoulli or Timoshenko
Year: 2016
Number Pages:
109-128pp.
Author(s): Correia, A.A.; Almeida, J.P.; Pinho, R.
: Computational Methods in Applied Sciences
Editor: Springer
Volume:
Vol. 3.
Keywords: Inelastic response; Boundary conditions; Flexural-shear-torsional interaction; Higher-order; Force-based; Beam element
Info
A finite-fault modeling of the 1755 Lisbon earthquake sources
A non
Year: 2009
Number Pages:
433-454.
Author(s): Carvalho, A. M.; Campos Costa, A.; Sousa Oliveira, C.
Editor: L.A. Mendes-Victor et al. (eds)
Keywords: Earthquake scenarios; Finite-fault modeling
Info
Simulating earthquake scenarios in the european project Lessloss: the case of Lisbon
N/A
Year: 2009
Number Pages:
233-243.
Author(s): Zonno, G.; Carvalho, A. M.; Franceschina, G.; Akinci, A.; Campos Costa, A.; Coelho, E.; Cultrera, G.; Pacor, F.; Pessina, V.; Cocco, M.
Editor: L.A. Mendes-Victor et al. (eds)
Keywords: Earthquake scenarios
Info
Shaking table testing
This text reflects the first of the four lectures that the author has presented at Udine, Italy, at CISM
Year: 2008
Number Pages:
165-196pp.
Author(s): Bairrão, R.
Editor: Springer Verlag
Keywords: Shaking table testing
|
Tese de Doutoramento
Info
Modelos estocáticos para a caracterização da acção sísmica em Portugal Continental
Um dos principais problemas e interesses da engenharia sísmica é a caracterizaçãoda acção sísmica, envolvendo a estimativa da intensidade, conteúdo em frequência,duração e variabilidade espacial dos movimentos intensos do solo mais gravosos, emtermos dos seus efeitos nas estruturas, que pode ocorrer num local.O presente trabalho de investigação desenvolve e aplica a metodologia estocástica etécnicas de modelação de fonte
Year: 2009
Author(s): Carvalho, A. M.
Keywords: Portugal continental; Risco sísmico; Fonte sísmica; Modelos estocásticos; Acção sísmica
Info
Risco sísmico em Portugal Continental
Os sismos são encarados frequentemente como desastres naturais inevitáveis. Todavia,deveriam ser considerados fenómenos naturais, cujos efeitos adversos podem ser minimizadoscaso se proceda a uma gestão efectiva do risco sísmico.O objectivo principal do presente trabalho de investigação é o de avaliar o risco sísmicoem Portugal Continental.Sendo um tema de natureza multidisciplinar, apresentam-se e discutem-se modelos deavaliação probabilística da perigosidade sísmica e sua desagregação, de vulnerabilidade efragilidade sísmicas de tipologias construtivas, de danos e de perdas económicas e humanas.Aplica-se a análise probabilística da perigosidade sísmica, e sua desagregação, aPortugal Continental, obtendo-se cenários modais capazes de reproduzir os níveis deperigosidade que os condicionam. Apresenta-se o inventário do parque habitacional e seushabitantes, descriminado por factores de vulnerabilidade, e classifica-se a sua vulnerabilidadesegundo os modelos de dano. Procede-se à actualização e aferição de uma metodologia parasimulação de cenários sísmicos, integrada num Sistema de Informação Geográfico. Avalia-seo risco sísmico, seguindo diversas abordagens, comparando-se os resultados com o risco deoutros países.Construiu-se assim uma ferramenta de avaliação de perdas devidas a sismos, queconstitui uma primeira contribuição para o desenvolvimento de um processo de gestão dorisco sísmico aplicado ao Continente Português.
Year: 2009
Author(s): Sousa, M. L.
Info
Avaliação da vulnerabilidade sísmica de edifícios de alvenaria
O parque habitacional de Portugal Continental contém algumas tipologias construtivas deelevada vulnerabilidade sísmica em relação às quais urge actuar no sentido de reduzir o riscosísmico a elas associado. No projecto de investigação
Year: 2008
Author(s): Candeias, P.
Keywords: Reforço sísmico; Vulnerabilidade sísmica; Ensaios sísmicos; Edifícios
|
|
Relatório Científico
Info
Avaliação de risco sísmico do edifício Sede I da EDP - Ensaios in situ de caracterização dinâmica e do comportamento mecânico da estrutura do edifício relatório final
O presente estudo teve como objetivo a caracterização dinâmica e do comportamento mecânico da estrutura do edifício Sede I da EDP, para uma adequada simulação do seu comportamento sísmico. Neste relatório descrevem-se os ensaios de identificação dinâmica in situ realizados, com base em vibrações ambiente e em vibrações forçadas, com o objetivo de recolher informação sobre as propriedades dinâmicas da estrutura como um todo e das suas lajes dos pisos elevados em particular. Foi efetuado o registo e a análise dos sinais de aceleração devido a vibração ambiente, medidos em diversos pontos do edifício, bem como devido a vibrações forçadas impostas num dos pisos enterrados do edifício. São também apresentados e analisados os ensaios de caracterização do comportamento mecânico de componentes estruturais relacionadas com a ligação das lajes mistas dos pisos elevados às paredes dos núcleos resistentes de betão armado do edifício. Estes consistem em ensaios destrutivos de troços de laje mista ligados aos núcleos, por meio de varões selados à parede, e em ensaios de arrancamento desses varões, tendo como objetivo caracterizar os materiais e componentes dos elementos estruturais. Esta informação é essencial para a posterior calibração dos modelos numéricos da estrutura e para uma realista simulação do seu comportamento sísmico, bem como para uma eventual deteção de anomalias estruturais decorrentes de patologias que possam comprometer o desempenho do edifício face à ocorrência de sismos.
Year: 2022
Author(s): Correia, A.A.; Candeias, P.; Ribeiro, F.; Gomes, J. P.
Keywords: Comportamento mecânico; Ensaios in situ; Vibração ambiente; Vibração forçada; Identificação dinâmica
Info
Metodologia para a avaliação da segurança sísmica de edifícios existentes baseada em análises de fiabilidade estrutural - Edifícios de betão armado
A avaliação da segurança sísmica de edifícios existentes tem como quadro de referência o Eurocódigo 8
Year: 2019
Author(s): Sousa, R.; Campos Costa, A.; Costa, A.
Keywords: Análise de fiabilidade estrutural; Metodologias expeditas; Avaliação da segurança sísmica; Edifícios existentes
Info
Mapas de perigosidade sísmica para Portugal Continental: Uma análise crítica - Parte I
Nos estudos probabilísticos para avaliação da perigosidade sísmica, são estabelecidas zonas de geração sísmica (zonas sismogénicas), representando regiões que partilham as mesmas caraterísticas sismológicas, tectónicas e geológicas e definidas as relações entre a frequência com que aí ocorrem os sismos e as respetivas magnitudes, num dado período de tempo. Em 2006, para o Anexo Nacional do Eurocódigo 8, foram consideradas e caraterizadas 11 zonas Sismogénicas para Portugal continental, adaptadas de estudos previamente elaborados em 1996. Entre 2008 e 2009, no âmbito dos projetos ERSTA e SHARE, foram propostas novas zonas sismogénicas, e estimados os respetivos parâmetros da lei de frequência - magnitude. Estas diferentes propostas resultaram em diferentes mapas de perigosidade sísmica para Portugal continental. A SPES, Sociedade Portuguesa de Engenharia Sísmica, espelhando a inquietude existente na comunidade científica face às diversas expressões da perigosidade sísmica em Portugal, e consciente da necessidade de um consenso perante os agentes decisores, considerou urgente a realização de um estudo criterioso acerca das opções tomadas, nos diferentes estudos, e suas implicações. É nestecontexto que surge este trabalho, que pretende fazer uma análise crítica e comparativa dos resultadosobtidos nos diferentes estudos mencionados e as suas implicações ao nível dos períodos de retorno para sismos de maior magnitude. Numa parte II, serão estudadas as implicações em termos de valores da perigosidade sísmica, para vários períodos de retorno e frequências espetrais.
Year: 2018
Author(s): Carvalho, A. M.; Malfeito, N.
Keywords: Sismos; Períodos de retorno; Perigosidade sísmica
Info
Segurança estrutural e sísmica das construções nas intervenções de reabilitação - Enquadramento jurídico da reabilitação urbana síntese dos instrumentos jurídicos e conceitos relevantes
O presente relatório, elaborado no âmbito de um estudo em curso no LNEC sobre a segurança sísmica das construções nas intervenções de reabilitação, sintetiza os instrumentos jurídicos e os conceitos relevantes para a análise do atual regime jurídico da reabilitação urbana (RJRU), e do regime excecional de reabilitação urbana (RERU).
Year: 2015
Author(s): Coelho, E.
Keywords: Instrumentos legais; Reabilitação urbana; Segurança sísmica
Info
Assessment of innovative solutions for non
This document reports the outcomes of the research project
Year: 2013
Author(s): Correia, A.A.; Candeias, P.; Campos Costa, A.; Coelho, E.; Vintzileou, E.; Palieraki, V.; Lourenço, P.; Leite, J.
Keywords: Innovative test setup; Shaking table test; Wire mesh coating reinforcement; Bed joint reinforcement; Reinforced concrete frames; Non-load bearing masonry enclosures
Info
Seismic performance of multi-storey timber buildings - Rusticasa building
This document reports the outcome of the seismic test on the Rusticasa building, the first in a total of four buildings included in the TIMBER BUILDINGS Project. This building is a log house system (LHS). The goal of the tests was to assess the seismic performance of the building, panel elements and steel connectors, defined in terms of relative displacements and hold-down forces.
Year: 2013
Author(s): Campos Costa, A.; Candeias, P.; Lourenço, P.; Branco , J.; Aranha, C.
Keywords: Steel connectors; Shaking table test; Log house system (LHS); Timber buildings
Info
Seismic performance of multi-storey timber buildings - LegnoCase building
This document reports the outcome of the seismic test on the LegnoCase building, the second in a total of four buildings included in the TIMBER BUILDINGS Project. This building is a platform frame system with sheathing assembled by means of OSB panels (PF-OSB). The goal of the tests was to assess the seismic performance of the building, panel elements and steel connectors, defined in terms of relative displacements and hold-down forces.
Year: 2013
Author(s): Campos Costa, A.; Candeias, P.; Piazza, M.; Bartolucci, C.; Tomasi, R.; Grossi, P.
Keywords: Shaking table test; Steel connectors; OSB panels; Timber buildings
Info
Seismic performance of multi-storey timber buildings - Rubnerhaus building
This document reports the outcome of the seismic test on the RubnerHaus building, the third in a total of four buildings included in the TIMBER BUILDINGS Project. This building is a platform frame system with sheathing assembled by means of gypsum fibre panel (PF-GF). The goal of the tests was to assess the seismic performance of the building, panel elements and steel connectors, defined in terms of relative displacements and hold-down forces.
Year: 2013
Author(s): Campos Costa, A.; Candeias, P.; Piazza, M.; Tomasi, R.; Grossi, P.
Keywords: Shaking table test; Steel connectors; Gypsum fibre panel (PF-GF); Timber buildings
Info
Seismic performance of multi-storey timber buildings - TUGraz building
This document reports the outcome of the seismic test on the TUGraz building, the fourth in a total of four buildings included in the TIMBER BUILDINGS Project. This building is a cross laminated system (CTL). The goal of the tests was to assess the seismic performance of the building, panel elements and steel connectors, defined in terms of relative displacements and hold-down forces.
Year: 2013
Author(s): Campos Costa, A.; Candeias, P.; Schickhofer, G.; Flatscher, G.
Keywords: Shaking table test; Steel connectors; Cross laminated system (CTL); Timber buildings
Info
The LNEC earthquake engineering testing facility. Background information: LNEC testing facility, testing setup and protocol and data processing
The TIMBER BUILDINGS Project, led by the University of Trento, included testing of four full scale multi-story timber houses with a realistic horizontal plan and three types of timber housing systems: platform frame system (PFS), log house system (LHS) and cross laminated timber (CLT). The tests were carried in the LNEC-3D shake table under different levels of excitation and different conditions of the structure.The tests were carried with the goal of assessing the seismic performance of the buildings, panel elements and steel connectors, defined in terms of relative displacements and hold-down forces.The results were presented in separate reports, one for each building. This document contains information common to the remaining four reports.
Year: 2013
Author(s): Campos Costa, A.; Candeias, P.; Piazza, M.; Tomasi, R.; Lourenço, P.; Branco , J.; Schickhofer, G.; Flatscher, G.
Keywords: Equipment; Shaking Table; Timber buildings
|
|
|
Outro
Info
Sensibilidade climática, capacidade adaptativa e de vulnerabilidades atuais e futuras da AML
Análise dos registos históricos de eventos climáticos e o seu impacto no setor da energia da AML, para identificar o grau em que este setor foi afetado por estímulos relacionados com o clima. Avaliação de capacidades adaptativas.
Year: 2019
Author(s): Marques da Silva, F.; Pinto, A.; Machado, P.
Keywords: Energia; Alterações climáticas
Info
A propósito da forma na engenharia do vento
Análise da forma das edificações nas ações do vento
Year: 2018
Author(s): Marques da Silva, F.
Keywords: Engenharia do vento; Aerodinãmica
Info
Forma e desenho urbano - efeitos na ventilação
As condicionantes arquitetónicas e de urbanização na ventilação natural
Year: 2018
Author(s): Marques da Silva, F.
Keywords: Engenharia do vento; Ventilação
Info
Wind and structures
Caracterização do vento. Ações sobre estruturas. Ensaios em túnel de vento
Year: 2017
Author(s): Marques da Silva, F.
Keywords: Wind tunnel; Actions on structures; Wind engineering
|