Artigos de Revista
Info
Framework for performance assessment of storm water systems
The integration of performance assessment may be determinant for water utilities and municipalities to improve their management practices regarding storm water systems (SWS). The use of performance assessment in the SW sector has been incipient, and the need to develop a performance assessment framework (PAF) that constitutes a reference for SWS was identified. The article aims to present a PAF, structured into eight objectives, 25 assessment criteria, and 80 performance metrics, namely performance indicators (PI), focusing on the assessment of SWS functioning, considering different performance dimensions and types of SWS. The PAF aims to promote the establishment of performance assessment systems in utilities, supporting the decision-making process and continuous improvement. The PAF was consolidated by incorporating the views and recommendations of two Portuguese water utilities during the validation process. Data collection process constitutes a barrier to the PAF application given the lack of financial and human resources in water utilities.
Ano: 2022
Número Páginas:
15 pp..
Autor(es): Santos, L.F.; Cardoso, M. A.; Galvão, A.
Revista: Urban Water Journal
Editor: Taylor & Francis
Volume:
Volume 19 - Issue 7.
Keywords: Water utilities; Performance metrics; Storm water; Framework; Performance assessment
Info
Key factors for activated carbon adsorption of pharmaceutical compounds from wastewaters: a multivariate modelling approach
O Método dos Mínimos Quadrados Parciais (PLS), uma generalização da regressão linear múltipla, é usado para modelar dados de remoção por adsorção de três compostos farmacêuticos (PhCs), de seis efluentes secundários de ETAR a diferentes carvões ativados em pó (PACs). Para a regressão PLS, foram considerados 25 descritores: 7 descritores relacionados com as propriedades dos PhCs, 10 descritores relacionadas com as propriedades dos efluentes e 8 descritores relacionados com as propriedades dos PACs. Esta abordagem de modelação mostrou boa capacidade descritiva, mostrando que as interações hidrófobas PhC-PAC desempenham o papel principal no processo de adsorção, sendo a energia de solvatação e log Kow os descritores mais adequados. Os resultados também sublinham a importância dos efeitos de competição da matéria orgânica dissolvida em água (DOM), nomeadamente dos compostos moderadamente hidrófobos impactando a capacidade de adsorção ou dos compostos hidrófilos carregados afetando a taxa de adsorção de curto prazo, enquanto a matriz inorgânica de água só parece impactar a capacidade de adsorção do PAC e não a adsorção de curto prazo. Para o conjunto de PAC testados, os resultados apontam para a área BET como um bom descritor da capacidade do PAC, enquanto a adsorção de curto prazo parece estar melhor relacionada com o volume de supermicroporos e a densidade do PAC. A melhoria dessas propriedades dos PAC devem ser consideradas como uma forma de refinar o seu desempenho. As correlações obtidas, envolvendo o impacto de descritores relacionados com as águas, os PhC e os PAC, mostram a existência de interações complexas que uma análise univariada não é suficiente para descrever.
Ano: 2022
Número Páginas:
1 p..
Autor(es): Viegas, R.M. C.; Mestre, A.S.; Mesquita, E.; Miguel Machuqueiro (FCUL); Andrade, M. A.; Carvalho, A. P.; Rosa, M. J.
Revista: Water
Editor: MDPI
Volume:
Volume 14, Issue 2.
Keywords: Regressão PLS; Multivariada; Águas residuais; Compostos farmacêuticos; Carvão ativado em pó; Adsorção
Info
Modelação do decaimento de cloro em sistema de distribuição de água para reutilização
A água residual tratada é uma fonte de água alternativa e a sua utilização contribui para a mitigação da escassez de água, através da aplicação da água para reutilização (ApR) em usos compatíveis, como rega de espaços verdes e lavagem de ruas. A modelação do decaimento de cloro em Sistemas de Distribuição de ApR (SDApR), englobando o decaimento de cloro no seio da água e o decaimento de parede, carece de estudos que proponham metodologias de implementação, bem como de trabalho experimental (laboratorial (e.g. testes de decaimento de cloro em ApR) e à escala real). Este artigo apresenta uma metodologia para modelação do decaimento de cloro em SDApR, tendo em conta a modelação hidráulica, o decaimento no seio da água e o decaimento devido à parede, que pretende servir de ferramenta de apoio à identificação das gamas de desinfetante a aplicar e a manter nas redes, contribuindo para promover uma adequada gestão e manutenção da desinfeção. As condições de operação do sistema, as características de qualidade da ApR e os requisitos de residual de cloro a manter na rede são condicionantes a considerar na modelação de um SDApR. Dados os níveis de amónia dos efluentes tratados em Portugal, deve ser dada especial atenção à seleção do desinfetante, propondo-se um residual de monocloramina.
Ano: 2022
Número Páginas:
13p..
Autor(es): Costa, J.; Ferreira, F.; Viegas, R.M. C.
Revista: Águas&Resíduos
Editor: APESB
Volume:
Série IV - n.º 11.
Keywords: Monocloramina; Modelação do decaimento de cloro; Desinfeção; Reutilização de águas urbanas; Sistemas de distribuição de água para reutilização
Info
Nature-Based Solutions for water management: insights to assess the contribution to urban resilience.
Assessing the Nature-Based Solutions (NBS) contribution to urban resilience, along with developing tools capable of demonstrating their long-term value, comprises a most needed step forward. Nevertheless, the NBS contribution to urban resilience has been yet slightly explored. Given the urban resilience complexity and multiple NBS capabilities, specific needs for a robust assessment should be investigated. This paper identifies the requirements for a comprehensive assessment of the NBS contribution to urban resilience and analyses the main assessment frameworks focused on resilience and NBS for urban drainage. First, the evolution of the resilience concept and relevant resilience assessment frameworks (RAF) are presented. Secondly, NBS challenges to enhance resilience and NBS assessment proposals are analysed. Thirdly, the attributes for assessing urban resilience and aspects to assess the NBS contribution are analysed. To conclude, a critical analysis of the assessment approaches is presented. Important challenges across the RAF have been identified, especially regarding their feasibility of application. Based on the performed analysis, most RAFs are not feasible for city benchmarking and assessing the resilience evolution over time, neither for assessing comprehensively the NBS contribution. Regarding specifically the NBS assessment proposals, just one focused on urban resilience was developed to date, which allows evaluating their contribution over time, between cities, or between different NBS.
Ano: 2022
Número Páginas:
108-134pp..
Autor(es): Beceiro, P.; Brito, R.; Galvão, A.
Revista: Blue-Green Systems
Editor: IWA Publishing
Volume:
Volume 4 - Issue 2.
Keywords: Water drainage sector; Urban resilience; Resilience assessment framework (RAF); Nature-based solutions (NBS); Cities
Info
Performance assessment of a storm water system in an estuarine area
Performance assessment is an important management tool in the water sector, and its integration on storm water systems
Ano: 2022
Número Páginas:
pp. 13-22.
Autor(es): Santos, L.F.; Cardoso, M. A.; Galvão, A.
Revista: Águas & Resíduos
Editor: APESB
Volume:
IV (10).
Keywords: Storm water systems; Performance assessment; Internal validation; Framework; Estuarine area, framework
Info
Powdered activated carbon full-scale addition to the activated sludge reactor of a municipal wastewater treatment plant: Pharmaceutical compounds control and overall impact on the process
Powdered activated carbon (PAC) dosing to a conventional activated sludge (AS) reactor is a low-investment option for controlling pharmaceutical compounds (PhCs) in municipal wastewater treatment, but its advantages and limitations in real operating environments are not fully assessed. A 3-week PAC-AS full-scale test was conducted in an oxidation ditch plant to assess PAC impact on effluent quality (PhCs, dissolved organic carbon (DOC) and other parameters), energy consumption, sludge production and costs. DOC-normalized PAC doses of 0.7
Ano: 2022
Número Páginas:
26 pp..
Autor(es): Campinas, M.; Viegas, R.M. C.; Almeida, C.M.M.; Martins, A.; Silva, C.; Mesquita, E.; Coelho, R.; Sofia, S.; Cardoso, V.V.; Benoliel, M. J.; Rosa, M. J.
Revista: Journal of Water Process Engineering
Editor: Elsevier
Volume:
Volume 49.
Keywords: Cost analysis; Powdered activated carbon-activated sludge; Municipal wastewater; Powdered activated carbon;; Pharmaceutical compounds
Info
Quality assessment of small urban catchments stormwater models: A new approach using old metrics
Small urban catchments pose challenges in applying performance metrics when comparing measured and simulated hydrographs. Indeed, results are hampered by the short peak flows, due to rainfall variability and measurement synchronization errors, and it can be both difficult and inconvenient to remove base flows from the analysis, given their influence on combined sewer overflow (CSO) performance. A new approach, based on the application of metrics to peak flows for a selected set of different durations, is proposed and tested to support model quality assessment and calibration. Its advantages are: avoiding inconveniences arising from lags in peak flows and subjectivity of possible adjustments; favouring the assessment of the influence of base flow variability and flow lamination by CSOs; promoting integrated analysis for a wide range of rainfall events; facilitating bias identification and also guiding calibration. However, this new approach tends to provide results (e.g., for NSE, r2 and PBIAS) closer to optimal values than when applying metrics to compare the measured and simulated values of hydrographs, so the comparison of results with thresholds widely used in the literature should be done with caution. The various case study examples highlight the importance of using a judicious set of different metrics and graphical analyses
Ano: 2022
Número Páginas:
28 pp..
Autor(es): David, L.; Mota, T.
Revista: Hydrology
Editor: MDPI
Volume:
9 (5).
Keywords: Kling-Gupta Efficiency (KGE); Nash
Info
Storm water systems
Performance assessment is recognized as an important management tool for urban water systems. This article describes the application of a performance assessment framework for storm water systems, in collaboration with two Portuguese urban water utilities. A performance assessment system was built for each water utility, including objectives, assessment criteria and performance metrics. The results showed the existence of areas vulnerable to flooding occurrences and the need for investment in rehabilitation. The application of the performance assessment framework supports the identification of systems
Ano: 2022
Número Páginas:
27 pp..
Autor(es): Santos, L.F.; Cardoso, M. A.; Galvão, A.
Revista: International Journal of Water Resources Development
Editor: Taylor & Francis
Keywords: Portugal; Water utility; Storm water systems; Water management; Performance metrics; Performance assessment
Info
The use of resilience metrics to support decision making in drinking water systems.
Performance assessment is essential for effectively managing drinking water systems. It allows to understand the system's behaviour, identify critical components and subsystems, and help with the decision analysis of measures to improve economic, infrastructural and water and energy resources. The current paper proposes an updated methodology for diagnosing drinking water networks, considering different perspectives: water and energy efficiency, infrastructural sustainability, and the quality of service provided, including resilience and redundancy concepts. Several performance indicators and indexes, including Resilience index and Entropy, are recommended to describe each perspective. The methodology is applied to a real-life network, and the attained results are discussed. The status quo situation for the network area is assessed, and the main problems are identified (i.e., high friction losses, inefficient pump operation, old pump equipment). Different improvement solutions are considered (e.g., pipe replacement with higher diameter, pump operation improvement, pump replacement). These interventions are considered individually or combined. Using the resilience-based perspective with other performance assessment criteria has provided a broader assessment. The resilience index has proven sensitive to the different alternatives, endorsing the system's efficiency. Smaller values of the resilience index indicate that a small amount of energy in excess is available as surplus energy in the consumption nodes, being dissipated, either as pumping inefficiencies, water losses, or friction and singular head losses. The Entropy metric is sensitive to the network layout and is helpful in alternatives that consider flow path alterations to prevent the impact of pipe failure. The best improvement alternative achieves a considerable enhancement in energy efficiency, maintains a good quality of service, improves the system's infrastructural sustainability, and corresponds to the highest resilience index value.
Ano: 2022
Número Páginas:
4p..
Autor(es): Carneiro, J.; Loureiro, D.; Covas, D.
Editor: WDSA / CCWI
Keywords: Alternative comparison; System diagnosis; Performance metrics; Resilience; Drinking water systems
Info
Uncertainty evaluation in time-dependent measurements
Data quality plays a strong role in modelling and is fundamental to ensure that obtained analyses and results are reliable. Data uncertainty is related to the measurement
Ano: 2022
Número Páginas:
16 pp..
Autor(es): Almeida e Silva, M.; Amado, C; Ribeiro, A.; Loureiro, D.
Revista: Measurement
Editor: Elsevier
Volume:
Volume 196.
Keywords: Uncertainly evaluation; Time-dependent measurements; Resampling; Model-based approach
|
Comunicações
Info
Urban services interdependencies and cascading events for floods in urban areas
Floods in urban areas are responsible for severe disruptions to services as well as for consequences in several dimensions, to people, built environment and society functions. These events are largely associated with natural phenomena and climate dynamics. Traditionally, drainage and civil protection services are involved in planning for facing floods but this is insufficient. A broader involvement of communities
Ano: 2022
Número Páginas:
5p..
Autor(es): Almeida, M. C.; Telhado, M.; Lopes, R.; Barreiro, J.; Brito, R.
Editor: ICUR
Keywords: Urban resilience; Cascade effects; Flooding; Climate change
Info
Afluências indevidas a sistemas de drenagem urbana: Uma abordagem integrada
As afluências individas a sistemas urbanos de água têm elevados impactos em diferentes dimensões, destacando-se o desempenho hidráulico, estrutural, ambiental, económico-financeiro, na saúde e segurança pública. O LNEC promoveu duas acções do projecto colaborativo iAFLUI - Iniciativa Nacional para o Controlo de Afluências Individas, onde foi desenvolvida, aplicada e consolidada uma metodologia para controlo destas afluências.
Ano: 2021
Número Páginas:
12 pp..
Autor(es): Almeida, M. C.; Brito, R.; Jorge, C.; Ribeiro, A.; Simões, C.
Editor: ENEG
Keywords: Sistemas de água urbanos; Monitorização; Avaliação de desempenho; Afluências indevidas
Info
Balanço energético em sistemas de águas residuais
Neste artigo apresenta-se o balanço energético específico para a avaliação da eficiência energética dos sistemas de águas residuais.
Ano: 2021
Número Páginas:
12.
Autor(es): Jorge, C.; Almeida, M. C.; Covas, D.
Editor: ENEG
Keywords: Sistemas de águas residuais; Estações elevatórias; Afluências indevidas; Eficiência energética; Balaço energético
Info
Contribuição de armazenamentos em áreas periurbanas na redução dos caudais de ponta a jusante
A Vala da Salgueirinha é uma linha de água efémera que se integra na rede mais vasta de valas de escoamento de águas pluviais e superficiais que atravessa toda a península de Setúbal. Sendo das linhas de água mais importantes do concelho de Palmela, é aquela que, em períodos de pluviosidade intensa, maiores perturbações provoca nos aglomerados urbanos, em vários troços da rede viária e nos campos ribeirinhos, devido a inundações. Presentemente, o Município de Palmela encontra-se a regularizar o troço jusante desta linha de água, numa extensão de 5.500 m. Este município pretende, numa segunda fase, proceder à regularização, para montante, da restante linha de água, numa extensão aproximada de 5.600 m, bem como à construção de uma bacia de retenção. Em alternativa ou complementarmente à bacia de retenção, poderão ser equacionados armazenamentos em outras áreas periurbanas, tirando vantagem das condições orográficas do terreno. Neste artigo apresentam-se os objetivos, a metodologia do trabalho e os resultados preliminares do estudo hidrológico que está a ser desenvolvido na bacia hidrográfica da Vala da Salgueirinha, a montante da localidade de Lagoínha, em Palmela. Prevê-se que com a conclusão do estudo seja possível quantificar a redução dos caudais de ponta recorrendo a armazenamentos relativamente naturais em áreas rurais, aumentando a eficiência da bacia de retenção a construir, ou permitindo reduzir o seu volume, diminuindo os custos de construção, expropriações e impactes gerados no local e contribuindo para uma maior harmonização da linha de água e sua envolvente.
Ano: 2021
Número Páginas:
4 pp..
Autor(es): Sousa, J.F.; David, L.; MARTINS, S.
Editor: APRH
Keywords: Inundações; Bacia de retenção; Modelação hidrológica; Drenagem urbana; SIG
Info
Eficiência hídrica de edifícios residenciais
Em resposta aos desafios relacionados com o uso eficiente da água, ao potencial de eficiência hídrica e ao nexus água-energia nos edifícios, e em resultado de um processo participativo envolvendo vários stakeholders, foi desenvolvido pela ADENE
Ano: 2021
Número Páginas:
5 pp..
Autor(es): Vieira, P.; Alegre, H.; Poças, A.; Cardoso, P.; Santos, P.; Newton, F.
Editor: APRH
Keywords: AQUA+; Edifícios; Nexus água-energia; Uso eficiente da água; Auditoria; Eficiência hídrica
Info
Enhanced control of recalcitrant pharmaceuticals and organic matter in urban wastewater treatment with pine nut shell CO2 activated carbons
Foi explorada em laboratório a produção de novos carvões ativados em pó (PAC) por ativação com vapor de água e com CO2 de cascas de pinhão (PNS), tendo sido testadas várias condições. Os PAC foram testados em ambiente operacional, com adsorção competitiva de três compostos farmacêuticos (PhC) em efluente secundário de ETAR, tendo o PAC activado com CO2 mostrado melhores remoções dos PhC do que o ativado com vapor de água. Ambos os PNS PAC superaram os melhores PAC comerciais testados.
Ano: 2021
Autor(es): Mestre, A.S.; Duque, L.P.; Mesquita, E.; Viegas, R.M. C.; Rosa, M. J.; Betz, W.; Carvalho, A. P.
Editor: Carbon Chemistry and Materials Conference
Keywords: ETAR; Tratamento; Compostos farmacêuticos; Cascas de pinhão; Novos carvões ativados em pó
Info
Fatores de contexto e técnicas de deteção de afluências indevidas pluviais, no sistema da Águas do Norte
Com esta comunicação pretende-se partilhar conhecimento sobre algumas técnicas disponíveis para identificação e localização de afluências indevidas potencialmente mais relevantes, com foco nas afluências de origem pluvial, desenvolvidas no âmbito do projecto colaborativo iAFLUI.
Ano: 2021
Número Páginas:
17 pp..
Autor(es): Vieira, A.; Santos, G.; Gonçalves, M.; Brito, R.; Almeida, M. C.
Editor: ENEG
Keywords: Águas residuais; Pluviais; Controlo; Afluências indevidas; Fatores de contexto
Info
Influence of activated carbon surface chemistry on the removal of pharmaceutical compounds from water
In the present work the surface chemistry of a commercial AC (NucharA74) was modified by thermal treatments at 500 ºC (NucharA74/500) and 800 ºC (NucharA74/800) under N2 (see pHPZC values on Table 1). The textural properties of the materials were characterized by N2 adsorption at -196 ºC and FTIR spectra. Materials were tested for the simultaneous removal of three PhCs (100 ?g/L) spiked in mineral aqueous solution. PhCs were selected considering their worldwide occurrence and persistence in wastewater treatment plant (WWTP) effluents (validated in LIFE IMPETUS, www.life-impetus.eu) and adsorption key-properties: carbamazepine (CBZ - neutral, hydrophobic), diclofenac (DCF - anionic, relatively hydrophobic) and sulfamethoxazole (SMX - anionic, hydrophilic). Concerning PhCs, DCF and CBZ were the most adsorbable compounds. The lower adsorbability of SMX may result from its hydrophilic character and higher polar surface area. The adsorptive capacity was generally more efficient for NucharA74/800, followed by NucharA74/500. The good performance of NucharA74/800 was attributed to its pHPZC value, as it has a lower negative net surface charge density than the other ACs. NucharA74/500 material, despite its high acidity and slightly smaller microporous volume than that of NucharA74, showed a higher adsorption capacity for all PhCs. Thus, the changes on the surface chemistry during the thermal treatment of NucharA74/500 may have favoured the adsorbent-adsorbate interactions, compensating the electrostatic repulsions.
Ano: 2021
Autor(es): Mestre, A.S.; Mesquita, E.; Lopes, A.; Rosa, M. J.; Carvalho, A. P.
Revista: Abstract book of the XI National Meeting on Catalysis and Porous Materials and the II Meeting of the Carbon Group
Editor: Sociedade Portuguesa de Química, Universidade de Aveiro
Keywords: Pharmaceutical compounds; Adsorption; Surface chemistry,; Activated carbon
Info
Melhoria da fiabilidade de sistemas de abastecimento de água recorrendo a algoritmos de optimização
O dimensionamento adequado de sistemas de distribuição de água é essencial para assegurar a eficiência e a eficácia do seu funcionamento. Tradicionalmente, o dimensionamento é efetuado atendendo apenas ao objetivo de minimização de custos, não sendo contemplados outros objetivos como o desempenho e a fiabilidade. Uma vez que é pretendido pelas Entidades Gestoras que os seus sistemas sejam capazes de manter o abastecimento perante situações anómalas, é fundamental que a fiabilidade seja tomada em conta no processo de dimensionamento do sistema. Este artigo apresenta os resultados de um trabalho exploratório de objetivos e de índices de fiabilidade. Apresenta uma metodologia para a escolha dos diâmetros das condutas de um sistema de distribuição de água, atendendo à minimização de custos e à maximização da fiabilidade do abastecimento em caso de ocorrência de uma avaria, com a análise de dois indicadores de fiabilidade, o Índice de Resiliência (RI) e o Índice de Resiliência da Rede (NRI). O problema de otimização é resolvido recorrendo a Algoritmos Genéticos, integrando as restrições relativas à pressão mínima e às velocidades máxima e mínima como penalizações na função objetivo. A aplicação da metodologia a um caso de estudo real resulta em três soluções de dimensionamentos distintas com objetivos contraditórios.
Ano: 2021
Autor(es): Carneiro, J.; Loureiro, D.; Covas, D.
Editor: ENEG
Keywords: Fiabilidade; Dimensionamento; Otimização; Sistemas de abastecimento água
Info
RESCCUE RAF app using technology to mitigate climate change urban impacts.
The constant expansion of urban areas ant its services has created new challenges to city managers. Climate Change (CC) is one of the most important topics, taking special importance in urban areas. Given its scalability, technology can take an important role to help city managers identify and mitigate specific CC-related problems in these areas. In this paper, a web application is presented to empower city managers with a tool that give them detailed data about their cities resilience to cope with CC, accessible from anywhere. The usage of this app allows city managers to take optimized measures to suppress weak areas of each city. This app is integrated as a service of the Portuguese Infrastructures Roadmap, under the Infraestrutura Nacional de Computação Distribuída (INCD) project INCD provides the resources for the apps data computation and storage, and assures its scalability to handle multiple user requests as well as database storage growth. This app uses a methodology of city assessment that goes deep into city services processes, identifying the specific areas that have higher vulnerability to CC hazards. The identification of these areas allows the city managers to implement incisive measures and to estimate costs of those measures improving the city resilience. Three case studies are being carried out in different cities (Barcelona, Lisbon and Bristol). Despite the complexity of the methodology of urban assessment, the RESCCUE RAF app can be accessed using a user-friendly interface that can be accessed from anywhere. The access requires authentication due to sensibility of information processed. After authentication, the user has access to a dedicated area where city information can be filled in, in an intuitive way such as: last review of City Master Plan, history of climate hazards or a detailed way of operation of city services. Then, taking advantage INCD infrastructure, this information is processed on-the-fly and several indicators are calculated. This information can then be explored within the app, at multiple levels, using intuitive and interactive chart and tabular information, from a macro view on overall city resilience to specific items like resilience of a specific process of a city service. These results can support targeted efforts and investments in the services that need to be improved. Given its importance and flexibility, the RESCCUE RAF App can be extended to other cities and take a major role in the urban resilience improvement to cope with climate change effects, contributing in the decision making process to avoid human, material and environmental losses.
Ano: 2020
Número Páginas:
8 pp..
Autor(es): Lopes, P.; Oliveira, A.; Pereira, C.; Brito, R.; Cardoso, M. A.; Martins, R.; David, M.; Gomes, J.; Pina, J.
Editor: MIPRO 2020
Keywords: Web application; Resilience; Assessment framework; Climate change
|
Livros
Info
Uso eficiente da água no sector urbano
O IRAR, enquanto regulador das entidades gestoras concessionárias deserviços de águas e resíduos em Portugal, tem seguido uma estratégia depermanente procura de sinergias através de parcerias com entidades daadministração e com instituições técnicas e científicas relevantes dosector, nomeadamente nos aspectos associados à temática do usoeficiente da água. De acordo com o disposto na alínea l) do artigo 11.º doDecreto-Lei n.º 362/98, de 18 de Novembro, com as alteraçõesintroduzidas pelo Decreto-Lei n.º 151/2002, de 23 de Maio, o IRAR temresponsabilidades na sensibilização das entidades gestoras e dosautarcas em geral para as questões da qualidade na concepção,execução, gestão e exploração dos sistemas multimunicipais emunicipais.O Instituto da Água (INAG), como organismo responsável pelodesenvolvimento e aplicação das políticas nacionais no domínio da água,promove a implementação do Programa Nacional para o Uso Eficiente daÁgua (PNUEA). Este Programa, cujas bases e linhas orientadoras foramaprovadas pela Resolução do Conselho de Ministros n.º 113/2005, de 30de Junho, constitui um instrumento de planeamento estratégico, no qualsão definidas as orientações de âmbito nacional para a promoção do usoeficiente da água nos sectores urbano, agrícola e industrial, contribuindopara minimizar os riscos de stress hídrico, quer em situação hídricanormal, quer durante períodos de escassez.O Laboratório Nacional de Engenharia Civil (LNEC) é uma instituição decarácter técnico e científico, competente e credenciada para a realizaçãode estudos em vários ramos da engenharia, nomeadamente nos domíniosda engenharia sanitária. Tem vindo a desenvolver estudos deinvestigação em áreas prioritárias, nomeadamente projectos para o INAGde definição e apoio à implementação do PNUEA, incluindo manuais paraa promoção do uso eficiente da água.Nesse âmbito, foi assinado em Março de 2005 um protocolo decooperação técnica e científica formalizando a colaboração entre estastrês entidades. Esse protocolo prevê a edição conjunta de um manual (ouguia técnico) dirigido, entre outras, às entidades gestoras de sistemas deabastecimento de água e de águas residuais, contendo orientaçõestécnicas para a implementação de medidas e de mecanismos promotoresdo uso eficiente da água no sector urbano.O objectivo é promover um uso mais eficiente da água, ou seja, optimizara utilização desse recurso - eficiência de utilização -, sem pôr em causaos objectivos pretendidos - eficácia de utilização - ao nível dasnecessidades vitais da sociedade, da qualidade de vida da população edo desenvolvimento sócio-económico do País. Pretende-se utilizar a quantidade óptima de água para conseguir os objectivos pretendidos, permitindo também, como benefícios indirectos, a redução da poluição dos meios aquáticos e a redução do consumo de energia, aspectos dependentes do consumo de água. Esta iniciativa integra-se no esforço de planeamento da água que o País tem vindo a efectuar, estando prevista não apenas no Plano Nacional da Água e nos Planos de BaciaHidrográfica, mas também no Plano Estratégico de Abastecimento deÁgua e de Saneamento de Águas Residuais 2000-2006.O resultado é a presente publicação, intitulada
Ano: 2006
Número Páginas:
203p.
Autor(es): Almeida, M. C.; Vieira, P.; Ribeiro, R.
Editor: IRAR / INAG / LNEC
Info
Controlo de perdas de água em sistemas públicos de adução e distribuição
O presente guia resulta de um protocolo estabelecido entre o LaboratórioNacional de Engenharia Civil (LNEC), o Instituto Regulador de Águas eResíduos (IRAR) e o Instituto da Água (INAG).O LNEC, na sua função de Laboratório de Estado, tem vindo adesenvolver, desde há mais de duas décadas, estudos de investigaçãoaplicada e de consultoria especializada no domínio da gestão técnica dossistemas de abastecimento de água, alguns dos quais no domínio docontrolo de perdas de água. Destaca-se um estudo de identificação, análisecrítica e sistematização das melhores práticas de controlo de perdas deágua realizado para a EPAL, S.A. em 1994 (Coelho et al., 1994) e aprodução de terminologia portuguesa (Hirner et al., 1999), estudos essesque se reflectem no conteúdo do presente manual.O IRAR tem como um dos seus objectivos estratégicos contribuir para amaior eficiência dos operadores, tanto regulados como não regulados,através de parcerias com as instituições técnicas e científicas maisrelevantes do sector. As perdas de água são, sem dúvida, uma dasimportantes causas de ineficiência dos operadores de sistemas deabastecimento, razão pela qual o IRAR tomou a iniciativa da elaboraçãodeste guia em colaboração com o LNEC e o INAG.O INAG é o organismo responsável pela implementação do ProgramaNacional para o Uso Eficiente da Água (PNUEA). Este programa preconizaa redução de perdas de água nos sistemas públicos de abastecimentocomo uma medida prioritária na melhoria da utilização do recurso água nosector urbano. O presente guia integra-se nos documentos de apoio emdesenvolvimento no âmbito da estratégia de implementação do referidoprograma.Este manual vem ajudar a colmatar uma lacuna que havia em termos debibliografia especializada adaptada às condições existentes em Portugal eescrita em português no domínio das perdas de água. Não constitui um fimem si mesmo, mas apenas o ponto de partida para uma abordagemprogressivamente mais universal e mais consolidada no domínio docontrolo das perdas de água nos serviços de abastecimento de água.Trata-se de um instrumento de trabalho para as entidades gestoras, aquem cabe a tarefa principal que é de o pôr em prática.
Ano: 2005
Número Páginas:
306p.
Autor(es): Alegre, H.; Coelho, S. T.; Almeida, M. C.; Vieira, P.
Editor: IRAR / Inst. Água / LNEC
Volume:
Série Guias Técnicos nº 3.
Keywords: Água
Info
Indicadores de desempenho para serviços de abastecimento de água
O LNEC tem vindo a apostar, há mais de uma década, na actividadeestratégica de I&D associada à temática da avaliação de desempenho desistemas de águas de abastecimento e águas residuais. Maisrecentemente, esta actividade expandiu-se também à área dos resíduossólidos. Consolidou-se, assim, a importância da qualidade do serviço nassuas várias vertentes, e conquistou-se uma importante dimensão deinternacionalização, nomeadamente com a publicação, pela InternationalWater Association (IWA), de Manuais de Boa Prática no âmbito dossistemas de abastecimento de água e de águas residuais publicados,respectivamente, em 2000 e 2003.Os trabalhos desenvolvidos tiveram como principais finalidades definir umametodologia de avaliação da qualidade do serviço prestado através de umconjunto de indicadores de desempenho e delinear alguns princípiosfundamentais para a sua implementação. A abordagem pretendeu serabrangente, visando cobrir as necessidades de diversos tipos deutilizadores tais como entidades gestoras dos sistemas, entidadesreguladoras, entidades financiadoras, organizações ambientais ou dedefesa do consumidor. Pretendeu-se igualmente que os resultados fossemaplicáveis a entidades de diferente dimensão, nível de desenvolvimento,clima, demografia e características sócio-culturais. É pois com grandesatisfação que vemos concretizada, no âmbito da colaboração protocoladacom o IRAR, a edição e adaptação para português da publicaçãoPerformance Indicators for Water Supply Services
Ano: 2004
Número Páginas:
277p.
Autor(es): Alegre, H.; Hirner, W.; Baptista, J. M.; Parena, R.
Editor: IRAR / LNEC
Volume:
Série Guias Técnicos.
Info
Performance Indicators for Wastewaters Services. Manual of Best Practice
N/A
Ano: 2003
Número Páginas:
192.
Autor(es): Matos, R. S.; Cardoso, M. A.; Ashley, R.; Duarte, P.; Molinari, A.; Shulz, A.
Editor: ******
|
Capítulos de Livros
Info
Controlling organic micropollutants in urban (waste) water treatment by activated carbon adsorption and membrane technology.
The number of climate-related disasters has progressively increased in the last two decades and this trend will drastically exacerbate in the medium- and long-term horizons according to climate change projections. In this framework, through a multi-disciplinary team and a strong background acquired in recent projects, ICARIA aims to promote the use of asset-level modeling to achieve a better understanding of climate related tangible direct and indirect impacts on critical assets due to complex, cascading, and compound disasters. Furthermore, it takes into account the related risk reduction provided by suitable, sustainable, and cost-effective adaptation solutions. ICARIA focuses on both (i) critical assets and services that were not designed for potential climate change-related impacts that can increase the unplanned outages and failures, and (ii) on housing, natural areas, and population. Cutting edge methods regarding climate scenario building, asset-level-coupled models, and multi-risk assessment approaches will be implemented and replicated in three EU regions to understand how future climate scenarios might affect critical assets and to provide decision-making support tools to private and public risk owners to assess the costs and benefits of various adaptation solutions.
Ano: 2023
Número Páginas:
141-180pp,.
Autor(es): Rosa, M. J.; Campinas, M.; Silva, C.; Mesquita, E.; Viegas, R.M. C.
Editor: IWA
Keywords: Compound events; Asset modeling; Cascading effects; Climate resilience; Critical assets
Info
Activated carbons in full-scale advanced wastewater treatment
Activated carbons are versatile adsorbents that can play a crucial role in the enhancement of wastewater treatment, namely by controlling organic microcontaminants of emerging concern (CECs) and organic matter. These materials have a 100-year market availability, large scientific testing at lab-scale and applicability in consolidated technologies. However, the use of activated carbons at full-scale wastewater treatment is still emerging, driven by the increasing awareness on environmental and human threats mainly resulting from CECs. The present chapter reviews the literature on the application of activated carbons in full- or large pilot-scale plants, highlighting the state-of-art knowledge on practical issues on operational set-ups, improvements on water overall quality, and costs. The selection criteria and properties of the powdered and granular (PAC and GAC) materials used, and the pros and critical aspects of their application, relevant for product development and process optimisation, are also analysed and determine the research needs proposed for a technical, economic, and environmentally sustainable application of activated carbon in full-scale advanced wastewater treatment.
Ano: 2022
Número Páginas:
44 pp..
Autor(es): Mestre, A.S.; Campinas, M.; Viegas, R.M. C.; Mesquita, E.; Carvalho, A.; Rosa, M. J.
Revista: Advanced Materials for Sustainable Environmental Remediation: Terrestrial and Aquatic Environments
Keywords: Cost analysis; Contaminants of emerging concern; Wastewater treatment; GAC; PAC
Info
Assessing urban resilience to cope with climate change (Cap. 7)
Urban areas are dynamic, complex, and vulnerable systems involving multiple strategic services such as water supply, wastewater, and stormwater and waste management. Climate-change trends may directly affect the urban water cycle, through heavy rainfall, tides, and droughts, potentially causing cascading impacts with serious consequences for people, the natural and built environments, and the economy. These challenges to urban areas require an integrated and sustainable approach to increase their resilience, with the allocation of the needed resources, including the development and implementation of disaster risk reduction (DRR) strategies, plans, and regulations in all relevant sectors. This chapter describes a resilience-assessment framework to be used by cities and urban-service managers. It considers a structured and objective-driven assessment aiming at supporting the development and monitoring of cities' and urban services' resilience action plans, thus contributing to appropriate DRR investments. Our approach considers four resilience dimensions: organizational, spatial, functional, and physical. It is aligned with the UNDRR's Disaster Resilience Scorecard for Cities and addresses the priorities of the Sendai Framework for Disaster Risk Reduction. In this chapter, we apply the resilience-assessment framework to the waste and mobility sectors in Lisbon (Portugal), identifying main opportunities to enhance their resilience and supporting the development of resilience and DRR strategies.
Ano: 2022
Número Páginas:
163-188pp..
Autor(es): Cardoso, M. A.; Almeida, M. C.; Telhado, M.; Morais, M.; Brito, R.
Revista: Investing in Disaster Risk Reduction for Resilience. Design, methods and knowledge in face of climate change
Editor: Elsevier
Keywords: Urban-resilience assessment; Multisectoral approach; Lisbon; Disaster risk reduction; Climate change; Adaptation strategies and measures
Info
Capítulo 11.4 - A avaliação da condição física de ativos verticais de sistemas urbanos de águas para apoio às operações de manutenção
Atualmente os sistemas urbanos de água são reconhecidos como infraestruturas indispensáveis de suporte para a prestação de serviços públicos de primeira necessidade à saúde e bem-estar das populações e à economia das sociedades
Ano: 2022
Número Páginas:
15 pp..
Autor(es): Cabral, M.; Loureiro, D.; Flores-Colen, I.; Covas, D.
Revista: Manual sobre Manutenção em edificações: estudos, técnicas e aplicações
Editor: Editora Universitária de Direito
Keywords: Manutenção; Sistemas urbanos de águas; Reabilitação; Avaliação da condição; Ativos verticais
Info
Investing in Disaster Risk Reduction for Resilience. Design, methods and Knowledge in the face of climate change.
Urban areas are dynamic, complex, and vulnerable systems involving multiple strategic urban services, stakeholders, and citizens. Strategic services essential to society include water and sewerage (water supply, and wastewater and stormwater management), waste management, energy supply, public lighting, transport, and public security. The potential effects of climate dynamics on the urban areas might lead to the aggravation of existing fragile conditions and the emergence of new hazards or risk factors, with major impacts on strategic urban services, people, the natural and built environment, and the economy. Climate change challenges to urban areas thus require an integrated and sustainable approach to increase their resilience, with the allocation of the needed resources at all administrative levels. These include the development and implementation of disaster risk reduction (DRR) strategies, policies, plans, laws, and regulations in all relevant sectors (UNISDR, 2015). This chapter describes a resilience assessment framework to be used by cities and urban-service managers. The framework considers a structured and objective-driven assessment aiming at supporting the development and monitoring of cities
Ano: 2022
Autor(es): Cardoso, M. A.; Brito, R.; Almeida, M. C.; Telhado, M.; Morais, M.
Revista: Investing in Disaster Risk Reduction for Resilience. Design, methods and Knowledge in the face of climate change.
Editor: Elsevier
Keywords: Lisbon; Urban resilience assessment; Multisector approach; Disaster risk reduction; Climate change; Adaptation strategies and measures
Info
Management of Urban Drainage Infrastructure
This chapter briefly presents concepts and methodologies to support the management of urban drainage infrastructure. After the introduction, data requirements for assessing the condition of urban drainage systems are presented. Data can be collected in different ways. Data analysis allows for determining structural and functional issues and system performance. The causes and consequences of failures are required for condition assessment and are the subject of the risk section. Any intervention in the urban drainage system has a cost that must be assessed. Mathematical modelling of the urban drainage systems has an advantage for evaluating the hydraulic and structural performance. Decisions on the management of urban drainage rehabilitation need to be addressed considering the different points of view or aspects that are often contradictory. This may be addressed by using multi-criteria decision analysis methodologies.
Ano: 2022
Número Páginas:
7p..
Autor(es): Carriço, N.; Almeida, M. C.; Leitão, J. P.
Revista: Routledge Handbook of urban water governance
Editor: Routledge
Keywords: Multi-criteria decision; Mathematical modelling; Urban drainage infrastructure
Info
Quality of measurement in urban water services: a metrological perspective
Urban water services make use of extensive networked infrastructures - water supply and drainage systems. Efficient management of these services relies on the quality of measurements of hydraulic variables in pipes and sewers to support robust analysis of systems
Ano: 2022
Número Páginas:
351 - 375.
Autor(es): Almeida, M. C.; Ribeiro, A.; Brito, R.
Revista: Advances on Testing and Experimentation in Civil Engineering
Editor: Springer Nature
Volume:
capitulo 15.
Keywords: Urban water systems; Uncertainty; Quality; Measurement; Accuracy
Info
Quality of measurement in urban water services: A metrological perspective
Urban water services make use of extensive networked infrastructures
Ano: 2022
Autor(es): Almeida, M. C.; Ribeiro, A.; Brito, R.
Revista: Advances on Testing and Experimentation in Civil Engineering
Editor: Springer Nature
Volume:
Cap. 15.
Keywords: Urban water systems; Uncertainty; Quality; ·Measurement
Info
Risk Analysis of Water Harvesting Systems
Rainwater harvesting systems (RWHS) can result in important benefits, but there are a number of potential negative risks. The risks associated with RWHS depend on several factors and duly consideration is required to ensure that risks associated with this type of solutions are low. Therefore, a generic and systematic approach to manage risk is required. This chapter introduces a brief overview of concepts and terminology adopted. Subsequently, an overview of common approaches to risk management is presented. The chapter focuses on specific aspects for the application of these approaches to RWHS, with emphasis on risk identification, specific risk treatment action, and monitoring. Different approaches on how to determine risks such as water safety plan (WSP), risk management process (RMP), and hazard analysis and critical control point (HACCP) can be used, but all of them have some common steps.
Ano: 2021
Número Páginas:
pp.179-192.
Autor(es): Almeida, M. C.; Santos, J.; Santos, J.; Eslamian, S.
Revista: Handbook of Water Harvesting and Conservation
Editor: John Wiley & Sons, Inc.
Volume:
Capitulo 12.
Keywords: Water safety plan; Risk management process; Risk analysis; Rainwater harvesting systems; Critical control point; Hazard analysis
Info
Removal of Cyanobacteria and Cyanotoxins by Conventional Physical-chemical Treatment
Conventional treatment processes for the removal of cyanobacteria and cyanotoxins are thoroughly described in this chapter, including chemical treatment (heavy metals, herbicides, and photosensitizers), coagulation/flocculation combined with air flotation, and various adsorption processes.
Ano: 2020
Número Páginas:
pp. 69-98.
Autor(es): Ribau, M. T.; Rosa, M. J.; Sorlini, S.; Biasibetti , M.; Christophoridis, C.; Edwards, C.
Revista: Water Treatment for Purification from Cyanobacteria and Cyanotoxins
Volume:
Chap. 3.
Keywords: Filtration; Activated carbon; Air flotation; Flocculation; Coagulation; Algicide; Chemical treatment; Adsorption
|
Teses de Doutoramento
Info
Assessment and improvement of energy use in wastewater systems
This research aims at developing a comprehensive approach for assessing the energy use and efficiency in wastewater systems, considering the water-energy-greenhouse gas (W-E-G) emissions nexus supported by methods and tools, such as a tailored energy balance and a performance assessment system (PAS). This approach is aligned with continuous improvement principles and allows carrying out the diagnosis of energy efficiency in wastewater systems supporting the building of a portfolio of energy use improvement measures responding to strategic objectives and attending to the systems
Ano: 2022
Autor(es): Jorge, C.
Keywords: Wastewater systems; Water-energy-greenhouse gas emissions nexus; Performance assessment; Energy efficiency; Energy balance
Info
Understanding Flow Dynamics in Drinking Water Storage Tanks
Drinking water storage tanks are essential components of water supply systems to store water, to level off pressure in networks and to meet emergency storage. They are also frequent sources of deterioration of drinking water quality and safety owing to inadequate tank design and operation. Mostly, existing tanks design, dimensions and operation do not account for water mixing and renewal.
Ano: 2022
Autor(es): Pinheiro, A.
Keywords: Chlorine decay.; Particle image velocimetry; Residence time distribution; Drinking water safety; Water storage tanks
Info
Assessing the contribution of Nature-Based Solutions to urban resilience. A comprehensive assessment framework with focus on stormwater management and control.
Nature-Based Solutions (NBS) are crucial to achieving the goals of the United Nations Agenda 2030 for sustainable development and other global agendas, such as the Paris Agreement on Climate Change. In the last decade, the NBS umbrella concept has become more relevant intending to contribute to urban resilience and to address the climate change challenges. NBS are living solutions inspired by nature that use or mimic natural processes intending to face several societal challenges, from the perspective of resource-efficient use and the promotion of economic and environmental benefits. Currently, cities are encouraged to understand and measure the NBS contribution to identify adequate strategies for enhancing resilience and prioritize investments accordingly. The objective of the present thesis is to promote and enhance the NBS implementation in cities, focused on solutions for stormwater management and control. Based on the analysis of their contribution to urban resilience, the potential to meet environmental, social, and economic challenges and to adapt across diverse urban scales and contexts is demonstrated. In this sense, a Resilience Assessment Framework (RAF) to assess the NBS contribution to urban resilience was developed. This framework aims to assess the NBS contribution to urban resilience. Moreover, a Guidance for the RAF application in cities with different resilience maturity was developed, which involved the RAF validation by seven cities (from a national and international context), that participated voluntarily in this phase. In this context, the developed RAF is comprehensive and multidimensional. It is driven by the definition of objectives, criteria, and metrics, according to the proposed structure for assessing the water supply and wastewater system service performance in the framework of the ISO 24500 standards of the International Organization for Standardization. For an oriented assessment of the criteria, qualitative and quantitative metrics were defined, considering data from different sources and complexity. Reference values were also identified and metrics' classifications were defined. In this classification, each answer is associated with a resilience development level, intending to assess the NBS contribution to urban resilience on a normalized scale. To support the RAF application to cities with different resilience maturity (in terms of resilience and available information), three analysis degrees (essential, complementary, and comprehensive) and a set of metrics were proposed, which are pre-defined in the guidance for the RAF application. To support the selection of the analysis degree more adequate to any city, a structure to characterize the city's profile was developed. This complementary profile also supports the interpretation of the RAF results, both at the city and at the level of specific NBS. To conclude, the application of the RAF essential analysis degree to the seven participating cities, with different challenges regarding urban resilience and NBS, and of the comprehensive analysis degree (complete RAF) to Porto´s urban area, through an assemble assessment at the city and NBS levels, were presented.
Ano: 2021
Autor(es): Beceiro, P.
Keywords: Urban resilience; Stormwater management; Resilience assessment framework; Nature-Based Solutions (NBS)
Info
Proposal and validation of a performance assessment framework for urban storm water systems
Over the past two decades, performance assessment (PA) has been one of the areas show-ing the greatest advancement in the water sector. PA aims to measure effectiveness and/or efficiency of an activity or process using performance metrics, supporting the decision-making process and the continuous improvement of water utilities. Despite the potential benefits, few projects, and initiatives on PA have been undertaken regarding storm water systems (SWS). The present thesis aims to develop a performance assessment framework (PAF), applicable to both conventional SWS and sustainable urban drainage systems (SUDS), objective driven and focused on systems
Ano: 2021
Autor(es): Santos, L.F.
Keywords: Water utilities; Storm water systems; Indicators; Performance metrics; Framework; Performance assessment
Info
Towards a better urban water infrastructure asset management by condition assessment and cost modelling
Infrastructure asset management (IAM) has been increasingly becoming a key topic in the mind-set shift of the water sector managers and policy makers, allowing to assist in the operational, tactical and strategic decision-making in urban water infrastructures. Nevertheless, IAM implementation by the water utilities is still far from needed and not widespread, due to several challenges and constraints, mainly associated with limited human, technological and financial resources. The current research aims at enhancing urban water infrastructure asset management through an integrated decision-making approach, that includes novel methodologies for condition assessment, service life prediction and cost modelling. This approach can be applied at three assessment levels
Ano: 2021
Autor(es): Cabral , M.
Keywords: Urban water assets; Decision-making; Cost modelling; Service life prediction; Condition assessment; Infrastructure asset management
Info
Melhoria na eficiência no uso da água e da energia em sistemas de abastecimento de água
Este trabalho tem como objetivo melhorar a eficiência energética dos sistemas de abastecimento de água através do desenvolvimento de uma metodologia orientada por objetivos e com recurso ao balanço energético e a métricas de desempenho que permitem identificar as principais origens de ineficiência energética dos sistemas, comparar diferentes alternativas de intervenção e contribuir para a melhoria contínua destes sistemas.A metodologia de investigação seguida contempla desenvolvimentos científicos aliados a uma aplicação prática num conjunto alargado de casos de estudo através de ferramentas de cálculo automático desenvolvidas para o efeito. Os desenvolvimentos científicos consistem na formulação matemática de um balanço energético flexível em termos de dados necessários para a sua implementação; o desenvolvimento de métricas de desempenho que permitem identificar a origem das ineficiências energéticas (equipamentos, perdas de água ou configuração e operação) e a sua sistematização numa metodologia que segue os princípios de melhoria contínua (Plan-Do-Check-Act). A aplicação a casos de estudo é efetuada em três etapas. A primeira etapa consiste na aplicação do balanço energético agregado e métricas de desempenho para diagnosticar ineficiências a nível global em sistemas sem modelo matemático. A segunda etapa consiste na aplicação de um balanço detalhado com recurso a modelos matemáticos, bem como uma análise de sensibilidade aos diferentes métodos. A terceira etapa centra-se na aplicação detalhada de dois casos de estudo para ilustrar a metodologia.Os principais resultados são: i) uma metodologia integrada para o diagnóstico água-energia em sistemas de abastecimento de água; ii) um novo balanço energético para sistemas de abastecimento de água; iii) resultados da aplicação do balanço e das métricas de eficiência energética em 110 sistemas; iv) ferramentas para cálculo das diferentes formulações de balanço energético e de métricas de desempenho; e v) valores reais e exemplos de soluções não convencionais que conduziram a melhorias de desempenho energético.
Ano: 2019
Autor(es): Mamade, A.
Keywords: Sistemas de abastecimento de água; Indicadores de desempenho; Balanço energético; Eficiência energética; Nexo água-energia
Info
Assessing and improving wastewater treatment performance. A contribution to the 3rd generation of the assessment system
As estações de tratamento de águas residuais (ETAR) são atualmente alvo de esforços de melhoria do seu desempenho técnico, ambiental e económico. Empresas, reguladores e organismos de financiamento têm utilizado sistemas de avaliação de desempenho para apoiar as suas decisões. Neste contexto, o LNEC desenvolveu a 1.ª e 2.ª geração do sistema de avaliação de desempenho (PAS) de ETAR baseado em indicadores (PIs) e índices de desempenho (PXs). Para ambos, os valores de referência para o julgamento do desempenho são elementos chave. Apesar de serem elementos cruciais, os valores de referência precisavam ainda de ser definidos para avaliar e melhorar o desempenho das ETAR com foco na eficiência energética e gestão de afluências pluviais. Assim, o objetivo da tese foi desenvolver a terceira geração do PAS com valores de referência para avaliar o desempenho. Os PIs e PXs focam os objetivos principais da ETAR, ou seja, garantir a sustentabilidade técnica, econômica e ambiental, garantindo um tratamento eficaz e fiável com o consumo mínimo de energia, reagentes e produção de lamas. A estratégia seguida consistiu em desenvolver ou selecionar a partir da segunda geração do PAS sub-conjuntos de PIs e PXs de acordo com os objetivos, nomeadamente, eficácia, fiabilidade, desempenho energético e consumo de reagentes e gestão das lamas. Os valores de referência foram derivados com base numa revisão da literatura, equações empíricas e/ou estudos de campo e, sempre que aplicável, incorporam o efeito de parâmetros chave, de modo a avaliar o efeito das variações de caudal e de concentração. Foi desenvolvida uma análise estatística dos PXs para avaliar a fiabilidade da ETAR. Foi também demonstrada a flexibilidade do sistema de avaliação de desempenho para diferentes objetivos e uma abordagem para diagnosticar oportunidades de melhoria do desempenho, utilizando os PIs e PXs num ciclo PDCA (plan-do-check-act).
Ano: 2016
Autor(es): Silva, C.
Keywords: WWTP; Reference values; Performance indices; Performance indicators; Performance assessment
Info
Avaliação e controlo da eficiência do tratamento de águas residuais - Aplicação a sistemas de pequena dimensão
Assiste-se, actualmente, a uma exigência crescente nos requisitos de qualidade das descargas de efluentes urbanos no meio hídrico receptor e, em paralelo, a uma maior pressão no sentido do aumento da eficiência na operação de ETAR, no que diz respeito ao consumo energético e de outros recursos. O objectivo principal da presente dissertação é o desenvolvimento de uma metodologia de monitorização, supervisão e controlo da eficiência do tratamento de águas residuais, adaptada especificamente a pequenas ETAR descentralizadas. Esta metodologia pode definir-se como um conjunto de estratégias de optimização baseadas, grandemente, na aquisição em linha de dados do processo e sua posterior utilização num modelo matemático para definição de cenários operacionais. Para além da metodologia, as principais contribuições inovadoras são a realização, durante um ano, de trabalho de monitorização num sistema de tratamento descentralizado, a utilização de métodos alternativos de monitorização de águas residuais e o desenvolvimento de um modelo matemático para a simulação do comportamento dinâmico de uma ETAR de pequena dimensão. O envolvimento do utilizador final constitui, igualmente, um aspecto importante do presente trabalho, o qual pretende lançar questões e vias de desenvolvimento para as entidades gestoras implementarem processos sustentados de optimização da operação em ETAR descentralizadas.
Ano: 2011
Número Páginas:
278p.
Autor(es): Ribeiro, R.
Keywords: Controlo; Modelação matemática; Monitorização; Lamas activadas; Sistemas descentralizados; Tratamento de águas residuais
Info
Metodologias de Análise de Consumos para a Gestão Eficiente de Sistemas de Distribuição de Água
Este trabalho de investigação teve como objectivo principal propor, aplicar e validar uma metodologia que permitisse transformar dados de consumo urbano de água, obtidos a partir de sistemas de telemetria, em informação útil para a gestão dos serviços de água e para os consumidores.A metodologia encontra-se estruturada em quatro módulos: planeamento e monitorização,processamento de dados, produção de informação de caracterização e previsão eclassificação. Tirando partido de dados de consumo telemedidos aos vários níveis, desde o cliente individual às zonas de medição e controlo (ZMC), procede-se à aplicação dametodologia para caracterização de grandes consumidores, previsão do consumodoméstico nocturno, avaliação do efeito da variação de pressão no consumo autorizado enas perdas de água e previsão do consumo em ZMC.Para além da metodologia estruturada para a análise de consumos, as principaiscontribuições inovadoras são o desenvolvimento de modelos de previsão e de classificação do consumo em ZMC, em função das variáveis explicativas mais significativas, e a obtenção de expressões para a variação do consumo autorizado e das perdas reais com a pressão.O trabalho desenvolvido contribuirá para um uso mais eficiente da água, através de ummelhor conhecimento sobre as várias componentes do consumo urbano de água, assimcomo para o estabelecimento de critérios de projecto e de exploração da rede maissustentados.
Ano: 2010
Número Páginas:
434p.
Autor(es): Loureiro, D.
Keywords: Perdas de água; Zona de medição e controlo; Telemetria; Uso eficiente da água; Consumo urbano de água; Sistema de abastecimento de água
Info
Avaliação de desempenho de estações de tratamento de água para consumo humano
Os serviços de abastecimento de água (SAA) têm vindo a incorporar princípios desustentabilidade na sua prática de gestão. O estado da arte em metodologias de avaliação dedesempenho de SAA mostrou a necessidade de abordar especificamente o tratamento,considerado insatisfatoriamente nas abordagens sistematizadas existentes.Na presente dissertação desenvolveu-se um sistema de avaliação de desempenho (PAS) deestações de tratamento de água (ETA), orientado por objectivos, normalizado e quantitativo,destinado a apoiar a tomada de decisão, e cobrindo os domínios qualidade da água tratada,eficiência/fiabilidade, utilização de água, energia e materiais, gestão de subprodutos, segurança,recursos humanos e económico financeiros.O PAS integra uma componente para avaliação do desempenho global, baseada em indicadoresde desempenho, e uma componente para avaliação do desempenho operacional, baseada emíndices de desempenho que avaliam, numa escala 0-300, a qualidade da água tratada, eficiênciasdas várias operações/processos unitários (OPU) e sua relação com condições de operação.Foi desenvolvida uma ferramenta de cálculo automático do PAS.A aplicação do PAS a cinco ETA de características diversas permitiu avaliar a evoluçãotemporal do seu desempenho, comparar estações e OPU, e identificar oportunidades de melhoriana operação das OPU, na qualidade da água tratada e utilização de recursos.
Ano: 2009
Autor(es): Vieira, P.
Keywords: Tratamento de água para consumo humano; Ferramenta de apoio à decisão; Operação de eta,; Índice de desempenho; Indicador de desempenho; Avaliação de desempenho
|
|
Relatórios
Info
Drivers and barriers for water-smart solutions across 6 Cases: policy and governance. B-WaterSmart
This report offers a preliminary overview of the main drivers and barriers related to the policy and governance dimensions across the six Living Labs of B-WaterSmart: Alicante (Spain), Bodø (Norway), East Frisia (Germany), Flanders (Belgium), Lisbon (Portugal) and Venice (Italy). It provides an overview of the policy framework with implications for water management in the European Union, including the main plans and strategies related to adaptation to climate change and implementation of a circular economy, along the nexus water-energy-resources-waste. Furthermore, we added a section that describes succinctly the main models of water governance in Europe.
Ano: 2022
Autor(es): Gomes, C.; Oliveira, R.; Schmidt, L.; Melo, M.; Damman, S.; Sarti, S.T.; Casals, I.; Rosell, L. F.; Mateo, M.R.; Elveos, M.; Lyngstad, S.U.; Vervaren, H.; Nies, J.; Paepe, S.; Raes, S.; Pronk, G.; Hen
Keywords: Policy framework; Governance; Water management
Info
Engineered and reusable nanoporous carbons for advanced water treatment.
The main objective of the EMPOWER+ project is to develop new high-performing GACs and PACs and reusable magnetic powdered activated carbons (MPACs), prepared by steam and CO2 activation of pine nut shells (PNS/Steam and PNS/CO2 activated carbons) following the protocol developed for PACs under the framework of LIFE Impetus project.
Ano: 2022
Autor(es): Mestre, A.S.; Mesquita, E.; Duque, L.P.; Rosa, M. J.; Viegas, R.M. C.; Betz, W.; Carvalho, A. P.
Keywords: Pharmaceutical compounds; Column and hybrid adsorption processes; Drinking water treatment; Novel activated carbons; Activated carbon adsorption
Info
MS16: The B-WaterSmart Assessment Framework, V0 (Supporting document)
MS16 consists of the first, preliminary version, V0, of the B-WaterSmart Assessment Framework (BWS AF) developed by WP6 in Task 6.2. The MS16 is composed of an excel file and this document. The excel file provides the list of elements forming the framework: the strategic objectives, the assessment criteria and the metrics proposed. This document, after background information about the BWS AF use, scope and development phases, describes the structure and the elements listed in the excel file. All the information provided by MS16 will be embedded into a web-application by end of April 2022, so to facilitate the validation phase carried out by the InAll, during the period April-August 2022.The planning of the period to release the web-application has been agreed with Task 1.4 and it is aligned with the activities planned within the InAll. Given the continuous work on refinement of metrics planned in collaboration with the InAll, the web-application, as well as this MS16, will be kept as living files for updating as and when required until the V2 of the BWS AF will be finalized.
Ano: 2022
Autor(es): Ugarelli, R.; Bosco, C.; Raspati, G.; Bruaset, S.; Cardoso, M. A.; Silva, C.; Rosa, M. J.; Alegre, H.; Koop , S.; Melo, M.; Oliveira, R.; Gomes, C.; Rosell, L. F.; Mateo, M.R.; Schmuck, A.; Strehl, C.
Keywords: European Commission; Assessment framework; Assessment criteria; B-watersmart
Info
Priorização de alternativas para melhoria da eficiência energética no subsistema D.S5-EEA3 da Inframoura.
Este trabalho envolve dois aspetos diferenciadores face a estudos anteriores: Diagnóstico aprofundado do subsistema D.S5-EEA3, quer espacial quer temporalmente, recorrendo à modelação hidráulica, aos cenários de operação de inverno e verão e cobrindo aspetos como a pressão, velocidade e idade da água na situação de referência e futura.Especificação e análise comparativa de alternativas (desempenho, custos, benefícios) para a sua priorização atendendo ao seu impacto a médio e longo-prazo (e.g., 10 anos e 20 anos).O diagnóstico aprofundado e a priorização de alternativas atenderão à evolução futura do sistema mediante cenários que serão identificados em conjunto com a EG, designadamente, alteração nos padrões de uso da água potável em usos não potáveis, com redução do seu uso para, por exemplo, rega de espaços públicos verdes, lavagem de ruas, climatização e alterações de contexto interno (e.g., expansão da rede do subsistema D.S5-EEA3). Este relatório visa apresentar a metodologia e o sistema de avaliação para diagnóstico aprofundado de subsistemas.
Ano: 2022
Autor(es): Loureiro, D.; Silva, C.; Carneiro, J.
Keywords: Sistemas urbanos de águas; Diagnóstico; Eficiência energética; Avaliação do desempenho
Info
Recommendations for refinement of the water-smartness framework and its transformation into a dashboard-type software
One of the key objectives of B-WaterSmart is to deliver a water-smartness assessment framework (BWS AF) fully tested in the six living labs (LLs) of the project. This deliverable aims at providing first recommendations to support both the refinement of the BWS AF and the development of the corresponding dashboard. This deliverable describes (i) the approach followed to obtain the recommendations within the innovation alliance (InAll), the InAll process (Task 1.4), and an overview of the testing process of BWS AF version V0 (delivered by WP6). It further presents (ii) the feedback on the framework from the LL problem-owners (LLi) (with support from WP6 for feedback collection and processing of raw results), the respective analysis, and subsequent recommendations both for refinement of the framework, and the development of the dashboard-type software to facilitate its use.
Ano: 2022
Autor(es): Cardoso, M. A.; Silva, C.; Rosa, M. J.; Alegre, H.; Ugarelli, R.; Bosco, C.; Raspati, G.; Casals, I.; González, E.; Mateo, M.R.; Rosell, L. F.; Lyngstad, S.U.; Elveos, M.; Muthanna, T. M.; Vervaeren,
Keywords: Dash-board; Recommendations; Assessment framework; Water-smartness
Info
The water-smartness assessment framework (V1)
D6.2 consists of the Version 1 of the B-WaterSmart Assessment Framework (BWS AF) developed by WP6 under Task 6.2. V1 builds on the V0 (MS16), which provided the preliminary list of the elements forming the framework. MS16 built on the theoretical background given by D6.1, describing the preliminary conceptual design of the framework. V1 is a transitional step between V0 and the final version V2 (by Task 6.3). To deliver V1, first the information provided by MS16 have been embedded into a web-application, to facilitate a validation phase carried out by the Innovation Alliance (InAll) under the coordination of Task 1.4 in the period April-August 2022. Afterwards, the InAll have been trained to the use of the web application and, by using the feedback forms made available, their insights have been shared with Task 6.2. The feedback has been analyzed by Task 6.2 in September and either already addressed in V1 or included in this document as input to Task 6.3. D6.2 is composed therefore by this supporting document and the web-application incorporating the updated version of the BWS-AF allowing further testing by the InAll. This document consists of two parts: part I includes background information about the BWS AF scope, the description of the co-creation process established with the InAll, and the updated version of the elements forming the framework V1 (incorporated in the web-application), as well as the aggregated analysis of the feedbacks provided by the InAll. Part II addresses Task 3.9, which will convert the BWS AF V2 into a dashboard, by sharing insights based on the experience gained during the development of the web-application and the validation phase. Last, D6.2 is closely related with D1.3 describing the scope and process of validation of V0 and also providing insights to Task 6.3 and Task 3.9 from the InAll perspective.
Ano: 2022
Autor(es): Ugarelli, R.; Damman, S.; Koop , S.; Alegre, H.; Cardoso, M. A.; Almeida, M. C.; Oliveira, R.; Vildåsen, S.S.; Raspati, G.; Barrero, M.J.; Termes, M.; Mateo, M.R.; Schmuck, A.; Strehl, C.; Lekawska-An
Keywords: Dash-board; Co-creation process; Assessment framework; Water-smartness
Info
Aplicação da metodologia para avaliação da eficiência do uso da água e da energia em aproveitamentos hidroagrícolas
O projeto AGIR
Ano: 2021
Autor(es): Loureiro, D.; Beceiro, P.; Moreira, M.; Sousa, G.; Chibeles, C.; Matos, M.
Keywords: Balanço energético; Balanço hídrico; Subsistema; Sistema de abastecimento de água; Período de análise; Entidade gestora (EG)
Info
Avaliação da eficiência do uso da água e da energia em aproveitamentos hidroagrícolas
O projeto AGIR
Ano: 2021
Autor(es): Loureiro, D.; Moreira, M.; Arranja, C.; Cordeiro, D.; Alegre, H.; Chibeles, C.; Sousa, G.; Matos, M.; Carriço, N.
Keywords: Balanço energético; Balanço hídrico; Subsistema; Sistema de abastecimento de água; Período de análise; Entidade gestora (EG)
Info
Avaliação da eficiência e sustentabilidade energética nos serviços urbanos de águas
No Projeto
Ano: 2021
Autor(es): Loureiro, D.; Silva, C.; Alegre, H.; Rosa, M. J.; Cabral , M.; Covas, D.
Keywords: Serviços urbanos de águas; Plano de ação; Medidas de melhoria; Eficiência energética; Avaliação de desempenho
Info
CoP's architecture and stakeholder mapping for each Living Lab
This deliverable introduces two of WP1
Ano: 2021
Autor(es): Rebelo, M.; Cardoso, M. A.; Alegre, H.; Andrews, L.; Mooren, C.; Munaretto, S.; Gomes, C.; Schmidt, L.; Oliveira, R.; Melo, M.
Keywords: Capacitation; Ethics; Stakeholders mapping; Communities of practice; Water smartness
|
|
|
Outros
Info
AWARE-P vence prémio alemão e conquista novo reconhecimento internacional
EXCLUSIVO: AWARE-P vence prémio alemão e conquista novo reconhecimento internacional: É a primeira vez que é distinguido um projecto de um país que não fala alemão, entrevista de Ana Santiago (Jornalista do Jornal Água & Ambiente - Portal Ambiente Online) a Helena Alegre, 19 de Agosto de 2014
Ano: 2014
Número Páginas:
1.
Autor(es): Alegre, H.
Info
Processos de pré oxidação e de desinfeção
N/A
Ano: 2014
Número Páginas:
36 slides.
Autor(es): Rosa, M. J.
Editor: APDA
Info
Vamos premiar quem aproveitou melhor a tecnologia
N/A
Ano: 2014
Número Páginas:
1p.
Autor(es): Alegre, H.
Editor: Ambiente on-line
Info
Ciência e inovação
N/A
Ano: 2012
Número Páginas:
1p.
Autor(es): Alegre, H.
Editor: About Media
Info
A engenharia sanitária no DHA em 2023
N/A
Ano: 2009
Autor(es): Alegre, H.
Info
Aplicações do modelo SWMM a casos de Estudo.
N/A
Ano: 2009
Autor(es): Brito, R. S.; David, L. M.
Info
Modelação dinâmica de sistemas de drenagem: Casos de estudo nacionais
N/A
Ano: 2009
Autor(es): Ferreira, F.; David, L. M.; Brito, R. S.
Info
Modelação dinâmica de sistemas de drenagem: Princípios de modelação e principais modelos existentes
N/A
Ano: 2009
Autor(es): Ferreira, F.; David, L. M.; Matos, J. S.
Info
Modelação estatística do consumo nocturno doméstico de água
N/A
Ano: 2009
Autor(es): Borba, R.; Amado, C.; Pacheco, A.; Loureiro, D.; Rebelo, M.; Alegre, H.; Coelho, S. T.; Covas, D.; Pina, A.
Info
O tratamento de água para consumo humano face à qualidade da água de origem
N/A
Ano: 2009
Autor(es): Rosa, M. J.; Vieira, P.; Menaia, J.
|