Artigos de Revista
Info
Innovative smart metering based applications for water utilities
Smart metering (SM) has the potential to improve distribution systems planning and operation and the overall system
Ano: 2014
Número Páginas:
16-20 pp..
Autor(es): Vieira, P.; Loureiro, D.; Barateiro, J.; Ribeiro, R.; Rebelo, M.; Coelho, S.T.
Revista: Water Utility Management International
Editor: IWA
Volume:
16.
Keywords: Water utilities; Use cases; Supply systems operation; Smart meter
Info
Modeling of chlorine decay in drinking water supply systems using EPANET MSX
The modelling of chlorine residual in water supply systems is of great importance in managing disinfectant concentrations throughout the network. First order decay kinetics are currently often used to describe both bulk and wall chlorine consumption. However, more complex approaches have been proposed, namely a parallel, two-reactant second order decay model (2R model) that has been reported as yielding better accuracy for simulating chlorine bulk decay in laboratory tests. The recent EPANET Multi-Species Extension (EPANET MSX) brought enhanced capabilities for the simulation of chlorine residuals in water supply systems, including the use of the 2R model or any other formulation. In the current paper, the performance of the 2R model as well as of first and nth order decay kinetics was assessed for full scale modelling of chlorine in a transmission system. Results have shown that a similar level of accuracy can be achieved with the three tested kinetic models, provided that a good calibration of the wall decay coefficient is accomplished. Although with improved modelling capabilities, the use of the stand- alone EPANET MSX was less user-friendly than normal EPANET application by the lack of a graphical interface allowing for the visualization of chlorine concentration profiles along the system. The use of the 3D-enabled Epanet Java web application circumvented such limitations. This tool together with a better characterization and estimation of the bulk and wall decay components allow for a more practical and accurate modelling of chlorine in water supply systems, while taking advantage of EPANET MSX's enhanced capabilities.
Ano: 2014
Número Páginas:
1192-1200pp.
Autor(es): Monteiro, L.; Figueiredo, D.; Dias, S.; Freitas, R.; Covas, D.; Menaia, J.; Coelho, S. T.
Revista: Procedia Engineering
Volume:
Nº 70.
Keywords: Epanet; Decay kinetics; Chlorine modelling; Drinking water quality
Info
Moving urban water infrastructure asset management from science into practice
iGPI, the National Initiative for Infrastructure Asset Management is a Portuguese collaborative project led by LNEC(National Civil Engineering Laboratory, Portugal) through which 19 water utilities develop their own infrastructure assetmanagement (IAM) systems and plans in a joint training and capacitation programme. Technical assistance to theparticipating utilities is ensured by LNEC, IST (Technical University of Lisbon) and Addition, a software developmentcompany. The water utilities get collective as well as one-on-one support and specific training. They benefit fromnetworking with the other utilities in a common and simultaneous process, with similar difficulties and challenges, leading toan effective sharing of solutions. The developed products, including training materials, templates and guidelines fordeveloping strategic and tactical IAM plans, are available to the general public. This project has greatly contributed to theestablishment of reference methodologies and standards for IAM planning, in a range of utilities of widely diverse size andcontext, effectively defining an accepted best practice. This paper discusses the project
Ano: 2014
Número Páginas:
9p.
Autor(es): Leitão, J. P.; Coelho, S. T.; Alegre, H.; Cardoso, M. A.; Silva, M. S.; Ramalho, P.; Ribeiro, R.; Covas, D.; Vitorino, D.; Almeida, M. C.; Carriço, N.
Revista: Urban Water Journal
Editor: Taylor & Francis
Keywords: Tactical planning; Strategic planning; Collaborative project; Infrastructure asset management; Urban water service
Info
Qualidade e tratamento de água e águas residuais. Desafios e oportunidades
Vivem-se hoje grandes e rápidas mudanças catalisadas por fortes pressões físicas e económicas. As alterações climáticas agravam os cenários e a incerteza a eles associada. São múltiplos e complexos os desafios que se colocam aos sistemas urbanos de água na proteção da saúde e do ambiente. Os contaminantes emergentes, as afluências pluviais, a reutilização de água, a capacidade de adaptação rápida a variações severas da água a tratar e a melhoria da eficiência energética são exemplos de desafios que exigem frequentemente soluções de compromisso e para os quais as ETA e as ETAR podem não estar preparadas, em Portugal e pelo mundo fora, uma vez que não foram considerados no seu projeto. As entidades gestoras têm agora que dar respostas e a inovação na exploração dos sistemas pode ser a chave para o sucesso. Inovação ao nível da abordagem, necessariamente integradora, de controlo na fonte e de remediação, e do benchmarking dos sistemas de tratamento, convencional e avançado, em cenários de seca e de precipitação, que permitam identificar onde, quando e como melhorar e intervir nos sistemas de tratamento e nas redes associadas (sistemas de abastecimento de água e de drenagem de residuais pluviais e residuais) são temas para os quais o LNEC tem vindo a procurar respostas, como aqui se pretendeu ilustrar.
Ano: 2014
Número Páginas:
4p.
Autor(es): Rosa, M. J.; Mesquita, E.; Silva, C.
Revista: Indústria e Ambiente
Editor: Engenho e Média, Lda
Volume:
Nº 84.
Info
Translating removal efficiencies into operational performance indices of wastewater treatment plants
Removal efficiencies are often used to assess the performance of a single or a group of unit operations/processes (UOPs) of a wastewater treatment plant (WWTP). However, depending on the influent concentration (Cin), the same efficiency of removal (Er) may be insufficient or excessive to achieve the UOP or WWTP effluent quality requirements, expressed by concentration limit values (LVs). This paper proposes performance indices (PXs), Er-based, as new metrics for benchmarking, i.e. for assessing and improving the performance of each UOP or treatment step and ultimately of the WWTP as a multi-barrier system, and comprehensively describes the step wise method of translating Ers into PXs. PXs are dimension less and vary between 0 and 300 to define three performance levels: unsatisfactory(0e100), acceptable(100e200) and good (200 - 300) performance. The method developed takes into consideration Cin and LV, and the reference values for judging the performance are given from Er-Cintypical ranges and Ervs. Cin model curves, LV based and field databased. The general equations of the Er model curves are derived. A set of six curves is calibrated for TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) removal by primary sedimentation and activated sludge systems (carbon or combined carbon and nutrients removal), using 5-year (2006 -2010) field data from five Portuguese WWTPs. A statistical analysis of the PX results is additionally proposed to assess treatment reliability. The new method is applied in two WWTPs and the PX results are compared with those of conventional measures
Ano: 2014
Número Páginas:
13 p.
Autor(es): Silva, C.; Quadros, S.; Ramalho, P.; Alegre, H.; Rosa, M. J.
Revista: Water research
Editor: Elsevier
Volume:
57 (2014) 202-214.
Keywords: Model curves; Modeling; Wastewater treatment plants; Removal efficiences; Performance indices; Performance indicators
Info
Enhanced DEM-based flow path delineation methods for urban flood modelling
In order to simulate surface runoff and flooding, one-dimensional (1D) overland flow networks can beautomatically delineated using digital elevation models (DEM). The resulting network comprises flowpaths and terrain depressions/ponds and is essential to reliably model pluvial (surface) floodingevents in urban areas by so-called 1D/1D models. Conventional automatic DEM-based flow pathdelineation methods have problems in producing realistic overland flow paths when detailed highresolutionDEMs of urban areas are used. The aim of this paper is to present the results of researchand development of three enhanced DEM-based overland flow path delineation methods; thesemethods are triggered when the conventional flow path delineation process stops due to a flowobstacle. Two of the methods, the
Ano: 2013
Número Páginas:
568-579pp.
Autor(es): Leitão, J. P.; Prodanovic, D.; Boonya-aroonnet, S.
Revista: Journal of Hydroinformatics
Editor: IWA
Volume:
Volume 15, Issue 2.
Keywords: Urban water; Pluvial flooding; Overland flow path delineation; Dual-drainage modelling; Digital elevation models
Info
Hydrogel floc nature and biogenic constituents of drinking water discolouration deposits
Loose deposits (LD) develop and accumulate in drinking water distribution systems' (DWDS) pipes and often lead to discolouration incidents, which are a major reason for customers' complaints. In addition, LD may accumulate contaminants, while discolouration may be accompanied by degradation of the water's microbiological quality. Along with iron oxides, organic compounds are well established as predominant constituents of LD. Even so, the composition and role of the latter remain unknown. Since microbial extracellular polymeric substances (EPS) are components of iron
Ano: 2013
Número Páginas:
10p.
Autor(es): Poças, A.; Miranda, A.; Paiva, J. M.; Benoliel, M. J.; Vreeburg, J.; Menaia, J.
Revista: Water Science Technology: Water Supply
Editor: IWA
Volume:
Volume 13 Number 6.
Keywords: Water discolouration; Loose deposits composition; Hydrogel flocs; Drinking water distribution systems
Info
Methodology for qualitative urban flooding risk assessment
Pluvial or surface flooding can cause significant damage and disruption as it often affects highlyurbanised areas. Therefore it is essential to accurately identify consequences and assess the risksassociated with such phenomena. The aim of this study is to present the results and investigate theapplicability of a qualitative flood risk assessment methodology in urban areas. This methodologybenefits from recent developments in urban flood modelling, such as the dual-drainage modellingconcept, namely one-dimensional automatic overland flow network delineation tools (e.g. AOFD) and1D/1D models incorporating both surface and sewer drainage systems. To assess flood risk, theconsequences can be estimated using hydraulic model results, such as water velocities and waterdepth results; the likelihood was estimated based on the return period of historical rainfall events. Totest the methodology two rainfall events with return periods of 350 and 2 years observed inAlcântara (Lisbon, Portugal) were used and three consequence dimensions were considered:affected public transportation services, affected properties and pedestrian safety. The most affectedareas in terms of flooding were easily identified; the presented methodology was shown to be easyto implement and effective to assess flooding risk in urban areas, despite the common difficulties inobtaining data.
Ano: 2013
Número Páginas:
829-838pp.
Autor(es): Leitão, J. P.; Almeida, M. C.; Simões, N. E.; Martins, A.
Revista: Water Science & Technology
Editor: IWA
Volume:
Volume 68, Issue 4.
Keywords: Surface urban flooding; Risk assessment; Flood modelling; 1d/1d urban drainage modelling
Info
Methodology for sampling drinking water discolouration loose deposits at low velocities
The occurrence of discoloured water at the tap is one of the most frequent reasons for customers tocomplain. Water discolouration arises from the re-suspension of loose deposits (LD) that accumulatein drinking water pipes, due to velocity increase. Because of its typical brownish/reddish colour,discoloured water is traditionally perceived as a consequence of cast-iron pipe corrosion, even innetworks devoid of cast-iron pipes. Current approaches for LD sampling imply the use of high flowvelocities within the range of those used for pipe self-cleaning (0.40 m/s) and/or pipe cleaning(1.50 m/s). Although useful for quantitative identification of critical zones and diagnosis of LDaccumulation, the application of such high-velocities as routine methodologies for LD sampling maybe difficult to perform on the field and provide samples with materials other than discolourationcausing LD. In this study, sampling velocities from 0.02 to 0.52 m/s yielded relatively large samples(up to 2 g dry weight), thus allowing for extensive qualitative LD analysis and testing. Samplerepresentativeness was analysed through the characterisation of LD key-constituents total iron (Fet)and volatile solids (VS). Turbidity decay trends showed the flocculent behaviour of discolourationcausing LD.
Ano: 2013
Número Páginas:
7p.
Autor(es): Poças, A.; Rebola, N.; Cordeiro, B.; Rodrigues, S.; Benoliel, M. J.; Vreeburg, J.; Menaia, J.
Revista: Water Science Technology: Water Supply
Editor: IWA
Volume:
Volume 13 Number 4.
Keywords: Sampling; Loose deposits; Drinking water; Distribution systems; Discolouration
Info
Modelling and understanding the competitive adsorption of microcystins and tannic acid
A predictive model integrating adsorption kinetics and competitive isotherm models (Homogeneous Surface Diffusion Model, Freundlich-type and Fritz& Schlunder isotherms) was developed to describe and understand the competing mechanism(s) and the ionic strength (IS) role on microcystins (MC) and tannic acid (TA) competitive adsorption. The developed model showed good agreement with the experimental data obtained from batch adsorption tests and isotherms conducted with MC extracts and TA model solutions (single-solute and multicomponent, IS presence and absence) using a mesoporous powdered activated carbon (PAC). Results con
Ano: 2013
Número Páginas:
10 p.
Autor(es): Campinas, M.; Viegas, R.M. C.; Rosa, M. J.
Revista: Water Research
Editor: Elsevier
Volume:
47.
Keywords: HSDM; Competitive adsorption models; PAC; NOM; Microcystins
|
Comunicações
Info
Performance assessment to support asset management in urban drainage systems
Urban drainage systems are one of the essential infrastructures in our societies. These network systems are capital intensive infrastructures, mostly buried, and crucial to ensure the health and safety of populations, continuity of socioeconomic urban functions, and protection of the environment.
Ano: 2022
Número Páginas:
4p..
Autor(es): Almeida, M. C.; Cardoso, M. A.; Brito, R.; Jorge, C.
Editor: LESAM
Keywords: Performance assessment; Urban drainage systems; Asset management
Info
Pine nut shell-derived carbons for improved drinking water treatment technologies
Water treatment improvement is mandatory to face current water quality challenges, being a focus of EU societal challenges. While the presence of micropollutants in natural waters, e.g. pharmaceutical compounds (PhCs) that resist to conventional treatments, constitutes an increasingly addressed issue, activated carbon (AC) adsorption is considered one of the best available technologies to control them during conventional [1] and advanced [2] drinking water treatment. The main objective of this work was the development of high-performing PACs prepared by steam activation of pine nut shells, conducted within EMPOWER+ project (https://empower.rd.ciencias.ulisboa.pt/).
Ano: 2022
Número Páginas:
3p..
Autor(es): Andrade, M. A.; Mesquita, E.; Viegas, R.M. C.; Carvalho, A. P.; Rosa, M. J.; Mestre, A.S.
Editor: RIA
Keywords: Water treatment; Pharmaceutical compounds; Adsorption; Novel activated carbons
Info
Protocol for water reclamation by ozone/reverse osmosis for safe direct potable reuse in beer production
Water scarcity and the increasing contamination of water resources are driving the use of alternative sources, such as the use of treated effluents. This study aims to demonstrate the combination of ozonation and reverse osmosis, at pilot scale, in batch and in continuous operation, to produce water to be used in the brewing industry. This solution sets a new paradigm of water use by testing a sound technology for water supply from treated wastewater. This pilot study aims to assess the impact of different operating conditions on the final water quality, checked against drinking water quality standards and for contaminants of emerging concern (e.g., pharmaceutical compounds, and multiple pathogens). To this end, 3000 L of water have been produced and used for craft beer production and a 24/7 study will be conducted until July 2022.
Ano: 2022
Número Páginas:
4p..
Autor(es): Galego, J.; Lourinho, R,; Figueiredo, D.; Costa, C.; Viegas, R.M. C.; Rosa, M. J.
Editor: IWA Publishing
Keywords: Contaminants of emerging concern; Water quality; Direct potable reuse
Info
SINERGEA - Energy: Modelling energy consumption in wastewater systems during rainfall events
The urban water cycle infrastructures are important consumers of electricity. Thus several efforts have been made recently to increase their energy efficiency. During rainfall events, the increase in flows pumped by interceptor sewers and treated in wastewater treatment plants (WWTP) can lead to significant increases in energy consumption. These flow increases occur not only in the combined sewer systems, but also in separate wastewater systems, due to water infiltration into the sewers, the rainfall-derived infiltration and inflow (RDII) component, and illicit misconnections between stormwater and sewage systems. Controlling rainfall-derived inflows into wastewater systems is a difficult challenge that has received increasing attention
Ano: 2022
Número Páginas:
2p..
Autor(es): David, L.; Pinto, A.; Oliveira, A.; Martins, A.; Ataíde, A.; Silva, O.
Editor: IAHR
Keywords: Energy modelling; Sinergia
Info
SINERGEA - Real-time forecasting system for managing floods, bathing water quality and wastewater energy consumption
Coastal cities face growing challenges from flooding, sea water quality and energy sustainability, which increasingly require an intelligent, real-time management. Urban drainage infrastructures often require pumping stations (PS) in low-lying areas, which transport to the wastewater treatment plant (WWTP) all waters likely to pollute downstream beaches, including rainfall-derived infiltration inflows and stormwater from small rain events. During the bathing season, decentralized management measures, including naturebased solutions, can be used to retain stormwater and promote its transport to the WWTP after the rainy event. However, the growth in pumped and treated flows increases energy consumption. In addition, realtime tools are required to support the assessment and prediction of the quality of bathing waters, to assess the possible need to prohibit beach water usage. During heavy rainfall events, decentralized management systems can also contribute to mitigate downstream flooding. Nevertheless, this requires the operation of the entire system to be different from that used to protect bathing water.
Ano: 2022
Número Páginas:
2p..
Autor(es): David, L.; Oliveira, A.; Rodrigues, M.; Fortunato, A. B.; Rogeiro, J.; Barreiro, J.; Ferreira, F.; Matos, J. S.; Santos, F.; Neves, R.; Martins, A.; Silva, O.; Ataíde, A.; Silva, N.; Freire, J.; Cravo
Editor: IAHR
Keywords: Real-time forcasting; Sinergia
Info
Sistemas prediais de distribuição de água não potável: quão útil pode ser a normalização europeia?
Associado ao crescimento populacional, as alterações climáticas e a progressiva urbanização da sociedade têm aumentado a pressão sobre os recursos hídricos. A par de mudanças comportamentais no uso da água e da utilização de dispositivos mais eficientes, a utilização de origens alternativas permite reduzir a pressão na captação de água no meio natural para a produção de água potável. As normas EN 16941-1:2018 e EN 16941-2:2021 têm como propósito o estabelecimento de requisitos para os sistemas de aproveitamento de águas pluviais (SAAP) e os sistemas de utilização de águas cinzentas tratadas (SUACT), respetivamente. Estas normas fornecem recomendações para o projeto, dimensionamento, instalação, identificação, comissionamento e manutenção dos referidos sistemas. Na EN 16941-2:2021, pelas características físico-químicas e microbiológicas das águas cinzentas, estão incluídos ainda aspetos relacionados com a monitorização da qualidade da água, algo que não acontece na EN 16941-1:2018. Ambas as normas fazem referência à abordagem fit-for-purpose, estabelecendo, assim, que o tratamento da água deve ter por objetivo a obtenção de características adequadas ao(s) uso(s) selecionado(s).
Ano: 2022
Número Páginas:
6p.
Autor(es): Ribeiro, R.; Poças, A.
Editor: APESB
Keywords: Utilização de águas cinzentas tratadas.; Uso eficiente da água; Reutilização de água; Normalização técnica; Aproveitamento de águas pluviais
Info
Solar Light-Induced Methylene Blue Removal by spent coffee grains derived activated carbons and TiO2 composites and their phoregeneration
Advanced technologies have the potential to ensure safe and sustainable water supply, a major global challenge of the near future. TiO2-containing photocatalyst, wich combine TiO2 with carbon-based materials, are promising materials for wastewater treatment due to synergistic photodegradation and adsorption phenomena. The purpose of this study was to develop TiO2/AC composites and test fresh and photo-regenetared materials for the removal of methylene blue in aqueous solutiopns prepared in ultrapure water or in wastewater effluent.
Ano: 2022
Número Páginas:
2p..
Autor(es): Carvalho, A. P.; Dalto, F.; Kuzniarska-Biernacka, I.; Pereira, C.; Mesquita, E.; Soares, O.S.; Pereira, M.F.; Rosa, M. J.; Mestre, A.S.; Freire, C.
Editor: Carbon
Keywords: Water treatment; UV regenerations; TiO2/AC composites
Info
Um método expedito para avaliar o cumprimento de critérios de segurança de pessoas em ruas inundadas
O produto da altura e da velocidade da inundação (h.V) é o critério mais utilizado para definir os limiares da estabilidade e segurança de pessoas e viaturas face à ação dos caudais de inundação. Na maioria dos casos, os critérios de segurança têm limitado h.V a valores entre 0,4 e 0,5 m2/s, embora estudos recentes proponham a redução até 0,22 m2/s em áreas urbanas. Neste artigo apresenta-se um método expedito que permite aferir o cumprimento de limites pré-estabelecidos do produto de
Ano: 2022
Número Páginas:
5p.
Autor(es): David, L.; Carvalho, R.
Editor: APESB
Keywords: Método expedito.; Incerteza; Drenagem urbana; Critérios de segurança; Inundações
Info
Uma abordagem integrada para gerir o uso de energia em sistemas de águas residuais
Neste artigo descreve-se uma abordagem que permite avaliar o uso de energia em sistemas de águas residuais, que inclui um sistema de avaliação de desempenho (SAD) centrado na eficiência energética, um balanço energético e um portfólio de medidas de melhoria do uso de energia, especificamente focados para sistemas de águas residuais. Esta abordagem enquadra-se no nível de planeamento tático, estando alinhada com os princípios de melhoria contínua nas organizações, como a gestão patrimonial de infraestruturas (GPI). A abordagem proposta permite a aplicação de um balanço energético específico em três níveis de avaliação e de um SAD que segue uma estrutura completa de objetivos, critérios e métricas para avaliar o desempenho ao nível da eficiência energética em sistemas de águas residuais. Estas ferramentas suportam a seleção de medidas de melhoria do uso de energia atendendo às especificidades de cada sistema, por exemplo, o controlo de afluências indevidas, as limitações de dados de cadastro, a medição de caudais, ou ferramentas de modelação. A metodologia orientada para objetivos foca-se no sistema como um todo, permitindo que as entidades gestoras de águas residuais desenvolvam uma avaliação estruturada a médio e longo prazo.
Ano: 2022
Número Páginas:
5p..
Autor(es): Jorge, C.; Almeida, M. C.; Covas, D.
Editor: ENASB
Keywords: Sistemas de águas residuais.; Avaliação de desempenho; Medidas de melhoria; Eficiência energética; Balanço energético
Info
Urban drainage asset management
Urban drainage systems have developed way beyond the traditional piped combined or separate sewer systems. Many
Ano: 2022
Número Páginas:
4p..
Autor(es): Langeveld, J.G.; Cherqui, N.; Gratl, F.; Muthanna, T.M.; Werey, C.; Rulleau, B.; Roghani, B.; Kerres, K.; Almeida, M. C.
Editor: LESAM
Keywords: Urban water infrastructure; Blue-green; Asset management
|
Livros
Info
Guia de avaliação dos serviços de águas e resíduos prestados aos utilizadores - 4th geração do sistema de avaliação
O Guia Técnico n.º 27 concretiza a 4.ª geração do sistema de avaliação da qualidade dos serviços da ERSAR, sendo o resultado de um excelente exemplo de colaboração entre a ERSAR, enquanto entidade reguladora, o Laboratório Nacional de Engenharia Civil e a Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, a quem não podíamos deixar de agradecer, alargando este agradecimento ao universo das entidades gestoras reguladas, cujos contributos prestados durante a consulta ao setor foram integrados nesta versão final.
Ano: 2024
Autor(es): Cardoso, M. A.; Rosa, M. J.; Brito, R.; Silva, C.; Beceiro, P.; Jorge, C.; Alegre, H.; Martinho, G.; Pina, J.; Silveira, A.; Alves, A.V.; Brito Ana, J.; Ramos, M.; Carrega, M.
Keywords: Indicadores chave de performance; Guia técnico 27; Ersar
Info
Technical guidelines for improved control of pharmaceutical compounds in urban wastewater treatment plants
The European project LIFE IMPETUS demonstrated low-investment, low-energy, flexible, and easy to implement measures for improving the removal of pharmaceutical compounds in urban wastewater treatment plants (WWTPs) with activated sludge (CAS) treatment, the most common biological process in those plants in Portugal and worldwide.The project addressed two major groups of technical solutions: i) operating strategies to enhance the biological treatment for PhC removal, measures identified using sound benchmarking tools, and ii) powdered activated carbon (PAC) addition to the biological reactor, using eco-friendly adsorbents, to control the recalcitrant PhCs and those with incomplete and variable biological removal. These technical guidelines compile the best practices and best lessons learned in LIFE IMPETUS project regarding PhC monitoring and improvement of PhC control in urban CAS-WWTPs using the approached technical solutions. The document aims at an easy and comprehensive use by water practitioners, water regulators, academia, and students of different backgrounds, answering to the questions of what, where, how, how much (cost), and when to monitor and control PhCs in urban CAS-WWTPs. Incentives for PhC control in urban WWTPs are also tackled.
Ano: 2024
Autor(es): Rosa, M. J.; Campinas, M.; Viegas, R.M. C.; Mesquita, E.; Silva, C.
Editor: LNEC
Keywords: Urban wastewater treatment; Technical guidelines; Pharmaceutical compounds; Life impetus; Activated sludge systems; Activated carbon adsorption
Info
Quality Assessment Guide for Water and Waste Services Provided to Users: 4th Generation Assessment System
The Technical Guide presents the 4th generation of the service quality assessment system, which abandons some 3rd generation indicators and adds new ones to respond to the latest challenges to supply services, urban waste water management and urban waste management. Changes are also made to definitions and benchmarks for some indicators are adjusted.
Ano: 2023
Número Páginas:
345p..
Autor(es): Cardoso, M. A.; Rosa, M. J.; Brito, R.; Silva, C.; Beceiro, P.; Jorge, C.; Alegre, H.; Martinho, G.; Pina, J.; Silveira, A.; Alves, A.V.; Brito Ana, J.; Ramos, M.; Carrega, M.
Editor: ERSAR/NOVA
Keywords: Benchmarking; Performance indicators; Waste services; Water services; Quality assessment
Info
Avaliação da eficiência energética nos serviçoes urbanos de águas. Guia para diagnóstico, priorização de alternativas, nonitorização e revisão do plano de ação
O projeto Avaler+
Ano: 2021
Número Páginas:
55 pp..
Autor(es): Loureiro, D.; Silva, C.; Cardoso, M. A.; Alegre, H.; Cabral , M.; Covas, D.; Rosa, M. J.
Editor: LNEC
Keywords: Serviços urbanos de águas; Plano de ação; Eficiência energética; Diagnóstico; Avaliação de desempenho
Info
Technical Guidelines PAC/MF
These technical guidelines provides guidance on the use of the hybrid process of powdered activate carbon adsorption and ceramic microfiltration for sustainable drinking water production. They were developed based on the field demonstration of the technology, in Portugal, with a pilot prototype, within the LIFE Hymenb project LIFE12 ENV/PT/001154 "Tailoring hybrid membrane processes for sustainable drinking water production", conducted by LNEC - the National Civil Engineering Laboratory and Águas do Algarve, S.A.
Ano: 2017
Número Páginas:
29 p.
Autor(es): Campinas, M.; Viegas, R.M. C.; Silva, C.; Rosa, M. J.
Editor: LNEC
Keywords: Technical guidelines; LIFE Hymemb; Emerging contaminants; Drinking water treatment; Ceramic microfiltration; Activated carbon adsorption
Info
Guia de avaliação da qualidade dos serviços de águas e resíduos prestados aos utilizadores - 2ª Geração do sistema de avaliação
O objetivo do presente Guia é a apresentação e a especificação dosistema correspondente à 2.ª geração de avaliação da qualidade dosserviços de abastecimento de água, de saneamento de águas residuaisurbanas e de gestão de resíduos urbanos prestados pelas entidadesgestoras sujeitas a regulação.Este sistema constitui uma peça fundamental do modelo de regulaçãoem implementação pela ERSAR, sumariamente descrito neste Guia emais detalhadamente descrito em [1], nomeadamente no que respeitaà componente da regulação da qualidade do serviço, de forma a tornarpossível a avaliação quantificada.Note-se que, de acordo com o disposto na alínea e) do n.º 1 do artigo 5.ºdo Decreto-Lei n.º 277/2009, de 2 de outubro, a ERSAR tem atribuiçõesnão apenas para assegurar a regulação da qualidade de serviço prestadoaos utilizadores pelas entidades gestoras, mas também para avaliaro desempenho dessas entidades, promovendo a melhoria dos níveis deserviço. É no quadro destas atribuições que se pretende promover estesistema de avaliação da qualidade dos serviços de águas e resíduos.A 2.ª geração do sistema de avaliação da qualidade do serviço resultouda análise crítica do sistema de indicadores adotado na 1.ª geração e darespetiva aplicação desde 2004 ao universo das entidades concessionáriase teve em conta o estado atual de conhecimentos e a experiênciainternacional entretanto adquirida.Para além da identificação e da especificação de todos os componentesdo sistema de avaliação, e em particular do conjunto de indicadores dequalidade do serviço a utilizar em cada um dos três tipos de serviços,são também definidos os procedimentos de avaliação, através dadefinição da informação a obter, do cálculo de indicadores, da sua interpretaçãoe análise comparativa, numa perspetiva de benchmarking, eda produção do relatório de síntese.
Ano: 2012
Número Páginas:
256p.
Autor(es): entidade LNEC
Editor: ERSAR/LNEC
Info
Adaptação e Sustentabilidade de Serviços de Abastecimento de Água e de Águas Residuais - RESUMOS
N/A
Ano: 2010
Número Páginas:
425p.
Autor(es): entidade LNEC
Editor: APESB
Info
Gestão patrimonial de infra-estruturas de abastecimento de água - Uma abordagem centrada na reabilitação
O texto está organizado em três partes e um conjunto de anexos (Figura 1.1). A primeira parte é de enquadramento geral, na segunda apresenta
Ano: 2010
Número Páginas:
510p.
Autor(es): Covas, D.; Alegre, H.
Editor: ERSAR / LNEC / IST
Keywords: Sistema de abastecimento de água; Rede de distribuição; Legislação; Guia; Eta; Captação de água; Água; Adutora
Info
Gestão patrimonial de infra-estruturas de águas residuais e pluviais - Uma abordagem centrada na reabilitação
A gestão patrimonial de infra
Ano: 2010
Número Páginas:
362p.
Autor(es): Almeida, M. C.; Cardoso, M. A.
Editor: ERSAR / LNEC
Keywords: Sistema de drenagem de águas residuais; Saneamento; Guia; Etar; Emissário
Info
Guia de avaliação da qualidade dos serviços de águas e resíduos prestados aos utilizadores. 2ª Geração do sistema de avaliação
O objectivo do presente Guia é a apresentação e a especificação do sistema correspondente à 2.ª geração de avaliação da qualidade dos serviços de abastecimento de água, de saneamento de águas residuais urbanas e de gestão de resíduos urbanos prestados pelas entidades gestoras sujeitas a regulação. Este sistema constitui uma peça fundamental do modelo de regulação em implementação pela ERSAR, sumariamente descrito neste Guia e mais detalhadamente descrito em [1], nomeadamente no que respeita à componente da regulação da qualidade do serviço, de forma a tornar possível a avaliação quantificada. Note-se que, de acordo com o disposto nas alíneas e) do artigo 5.º do Decreto-Lei n.º 277/2009, de 2 de Outubro, a ERSAR tem atribuições não apenas para assegurar a regulação da qualidade de serviço prestado aos utilizadores pelas entidades gestoras bem como para avaliar o desempenho dessas entidades, promovendo a melhoria dos níveis de serviço. É no quadro destas atribuições que se pretende promover este sistema de avaliação da qualidade dos serviços de águas e resíduos. A 2.ª geração do sistema de avaliação da qualidade do serviço resultou da análise crítica do sistema de indicadores adoptado na 1.ª geração e da respectiva aplicação desde 2004 ao universo das entidades concessionárias e teve em conta o estado actual de conhecimentos e a experiência internacional entretanto adquirida. Para além da identificação e da especificação de todos os componentes do sistema de avaliação, e em particular do conjunto de indicadores de qualidade do serviço a utilizar em cada um dos três tipos de serviços, são também definidos os procedimentos de avaliação, através da definição da informação a obter, do cálculo de indicadores, da sua interpretação e análise comparativa, numa perspectiva de benchmarking, e da produção do relatório de síntese.
Ano: 2010
Autor(es): entidade LNEC
Revista: ERSAR / LNEC
|
Capítulos de Livros
Info
Academia da Água: a construir o futuro
Os objetivos da nova DARU são ambiciosos, exigindo maior eficácia e eficiência
Ano: 2024
Número Páginas:
61-66pp..
Autor(es): Rosa, M. J.; Silva, C.
Revista: Academia da Água: a construir o futuro
Editor: APRH
Keywords: Planeamento; Micropoluentes; Neutralidade energética; Daru
Info
Asset management of urban drainage systems
Asset management (AM) has become increasingly important in various sectors and organizations over the lastfew decades. This introductory chapter provides an overview of asset management to facilitate a comprehensive understanding of AM, summarizing its application to urban drainage asset management (UDAM), an asset-intensive sector. The chapter includes a short history, from general AM to UDAM, and refers to milestones, key organizations, and standards. It describes AM principles and different perspectives to approach the subject. The UDAM context is outlined, providing the general processes which can influence strategic, tactical, or operational decision levels, accounting for the specific perspectives and objectives on the subject. The main approaches applied to UDAM are broadly described, some of which incorporate a balance of costs, risks, opportunities, and performance, while others focus on specific aspects. The chapter presents different types of approaches to AM, ranging from those based on condition, reliability, and risk to those based on value, followed by those based on performance or quality of service, highlighting common aspects or overlaps between them. When appropriate, guidance to the chapters where additional information on the subject can be found is provided. Finally, challenges, limitations and opportunities are highlighted.
Ano: 2024
Número Páginas:
32p..
Autor(es): Almeida, M. C.; Kropp, l.
Revista: Asset Management of Urban Drainage Systems: If anything exciting happens, we've done it wrong!
Editor: IWA Publishing
Keywords: Urban drainage.; Strategic planning; Risk management; Reliability; Performance; Information management; Condition, cost; Asset management
Info
Controlling organic micropollutants in urban (waste) water treatment by activated carbon adsorption and membrane technology.
The number of climate-related disasters has progressively increased in the last two decades and this trend will drastically exacerbate in the medium- and long-term horizons according to climate change projections. In this framework, through a multi-disciplinary team and a strong background acquired in recent projects, ICARIA aims to promote the use of asset-level modeling to achieve a better understanding of climate related tangible direct and indirect impacts on critical assets due to complex, cascading, and compound disasters. Furthermore, it takes into account the related risk reduction provided by suitable, sustainable, and cost-effective adaptation solutions. ICARIA focuses on both (i) critical assets and services that were not designed for potential climate change-related impacts that can increase the unplanned outages and failures, and (ii) on housing, natural areas, and population. Cutting edge methods regarding climate scenario building, asset-level-coupled models, and multi-risk assessment approaches will be implemented and replicated in three EU regions to understand how future climate scenarios might affect critical assets and to provide decision-making support tools to private and public risk owners to assess the costs and benefits of various adaptation solutions.
Ano: 2023
Número Páginas:
141-180pp,.
Autor(es): Rosa, M. J.; Campinas, M.; Silva, C.; Mesquita, E.; Viegas, R.M. C.
Editor: IWA
Keywords: Compound events; Asset modeling; Cascading effects; Climate resilience; Critical assets
Info
Activated carbons in full-scale advanced wastewater treatment
Activated carbons are versatile adsorbents that can play a crucial role in the enhancement of wastewater treatment, namely by controlling organic microcontaminants of emerging concern (CECs) and organic matter. These materials have a 100-year market availability, large scientific testing at lab-scale and applicability in consolidated technologies. However, the use of activated carbons at full-scale wastewater treatment is still emerging, driven by the increasing awareness on environmental and human threats mainly resulting from CECs. The present chapter reviews the literature on the application of activated carbons in full- or large pilot-scale plants, highlighting the state-of-art knowledge on practical issues on operational set-ups, improvements on water overall quality, and costs. The selection criteria and properties of the powdered and granular (PAC and GAC) materials used, and the pros and critical aspects of their application, relevant for product development and process optimisation, are also analysed and determine the research needs proposed for a technical, economic, and environmentally sustainable application of activated carbon in full-scale advanced wastewater treatment.
Ano: 2022
Número Páginas:
44 pp..
Autor(es): Mestre, A.S.; Campinas, M.; Viegas, R.M. C.; Mesquita, E.; Carvalho, A.; Rosa, M. J.
Revista: Advanced Materials for Sustainable Environmental Remediation: Terrestrial and Aquatic Environments
Keywords: Cost analysis; Contaminants of emerging concern; Wastewater treatment; GAC; PAC
Info
Assessing urban resilience to cope with climate change (Cap. 7)
Urban areas are dynamic, complex, and vulnerable systems involving multiple strategic services such as water supply, wastewater, and stormwater and waste management. Climate-change trends may directly affect the urban water cycle, through heavy rainfall, tides, and droughts, potentially causing cascading impacts with serious consequences for people, the natural and built environments, and the economy. These challenges to urban areas require an integrated and sustainable approach to increase their resilience, with the allocation of the needed resources, including the development and implementation of disaster risk reduction (DRR) strategies, plans, and regulations in all relevant sectors. This chapter describes a resilience-assessment framework to be used by cities and urban-service managers. It considers a structured and objective-driven assessment aiming at supporting the development and monitoring of cities' and urban services' resilience action plans, thus contributing to appropriate DRR investments. Our approach considers four resilience dimensions: organizational, spatial, functional, and physical. It is aligned with the UNDRR's Disaster Resilience Scorecard for Cities and addresses the priorities of the Sendai Framework for Disaster Risk Reduction. In this chapter, we apply the resilience-assessment framework to the waste and mobility sectors in Lisbon (Portugal), identifying main opportunities to enhance their resilience and supporting the development of resilience and DRR strategies.
Ano: 2022
Número Páginas:
163-188pp..
Autor(es): Cardoso, M. A.; Almeida, M. C.; Telhado, M.; Morais, M.; Brito, R.
Revista: Investing in Disaster Risk Reduction for Resilience. Design, methods and knowledge in face of climate change
Editor: Elsevier
Keywords: Urban-resilience assessment; Multisectoral approach; Lisbon; Disaster risk reduction; Climate change; Adaptation strategies and measures
Info
Capítulo 11.4 - A avaliação da condição física de ativos verticais de sistemas urbanos de águas para apoio às operações de manutenção
Atualmente os sistemas urbanos de água são reconhecidos como infraestruturas indispensáveis de suporte para a prestação de serviços públicos de primeira necessidade à saúde e bem-estar das populações e à economia das sociedades
Ano: 2022
Número Páginas:
15 pp..
Autor(es): Cabral, M.; Loureiro, D.; Flores-Colen, I.; Covas, D.
Revista: Manual sobre Manutenção em edificações: estudos, técnicas e aplicações
Editor: Editora Universitária de Direito
Keywords: Manutenção; Sistemas urbanos de águas; Reabilitação; Avaliação da condição; Ativos verticais
Info
Global Trends & Challenges in Water Science, Research and Management
This paper aims to explain why and how innovative technologies are enablers of strategic asset management (SAM) of water supply, wastewater and storm water systems.
Ano: 2022
Número Páginas:
8p..
Autor(es): Brito, R.; Alegre, H.
Revista: Global Trends & Challenges in Water Science, Research and Management
Editor: IWA Publishing
Keywords: Climate change; Water services and public health; Strategic asset management
Info
Investing in Disaster Risk Reduction for Resilience. Design, methods and Knowledge in the face of climate change.
Urban areas are dynamic, complex, and vulnerable systems involving multiple strategic urban services, stakeholders, and citizens. Strategic services essential to society include water and sewerage (water supply, and wastewater and stormwater management), waste management, energy supply, public lighting, transport, and public security. The potential effects of climate dynamics on the urban areas might lead to the aggravation of existing fragile conditions and the emergence of new hazards or risk factors, with major impacts on strategic urban services, people, the natural and built environment, and the economy. Climate change challenges to urban areas thus require an integrated and sustainable approach to increase their resilience, with the allocation of the needed resources at all administrative levels. These include the development and implementation of disaster risk reduction (DRR) strategies, policies, plans, laws, and regulations in all relevant sectors (UNISDR, 2015). This chapter describes a resilience assessment framework to be used by cities and urban-service managers. The framework considers a structured and objective-driven assessment aiming at supporting the development and monitoring of cities
Ano: 2022
Autor(es): Cardoso, M. A.; Brito, R.; Almeida, M. C.; Telhado, M.; Morais, M.
Revista: Investing in Disaster Risk Reduction for Resilience. Design, methods and Knowledge in the face of climate change.
Editor: Elsevier
Keywords: Lisbon; Urban resilience assessment; Multisector approach; Disaster risk reduction; Climate change; Adaptation strategies and measures
Info
Management of Urban Drainage Infrastructure
This chapter briefly presents concepts and methodologies to support the management of urban drainage infrastructure. After the introduction, data requirements for assessing the condition of urban drainage systems are presented. Data can be collected in different ways. Data analysis allows for determining structural and functional issues and system performance. The causes and consequences of failures are required for condition assessment and are the subject of the risk section. Any intervention in the urban drainage system has a cost that must be assessed. Mathematical modelling of the urban drainage systems has an advantage for evaluating the hydraulic and structural performance. Decisions on the management of urban drainage rehabilitation need to be addressed considering the different points of view or aspects that are often contradictory. This may be addressed by using multi-criteria decision analysis methodologies.
Ano: 2022
Número Páginas:
7p..
Autor(es): Carriço, N.; Almeida, M. C.; Leitão, J. P.
Revista: Routledge Handbook of urban water governance
Editor: Routledge
Keywords: Multi-criteria decision; Mathematical modelling; Urban drainage infrastructure
Info
Quality of measurement in urban water services: a metrological perspective
Urban water services make use of extensive networked infrastructures - water supply and drainage systems. Efficient management of these services relies on the quality of measurements of hydraulic variables in pipes and sewers to support robust analysis of systems
Ano: 2022
Número Páginas:
351 - 375.
Autor(es): Almeida, M. C.; Ribeiro, A.; Brito, R.
Revista: Advances on Testing and Experimentation in Civil Engineering
Editor: Springer Nature
Volume:
capitulo 15.
Keywords: Urban water systems; Uncertainty; Quality; Measurement; Accuracy
|
Teses de Doutoramento
Info
Assessment and improvement of energy use in wastewater systems
This research aims at developing a comprehensive approach for assessing the energy use and efficiency in wastewater systems, considering the water-energy-greenhouse gas (W-E-G) emissions nexus supported by methods and tools, such as a tailored energy balance and a performance assessment system (PAS). This approach is aligned with continuous improvement principles and allows carrying out the diagnosis of energy efficiency in wastewater systems supporting the building of a portfolio of energy use improvement measures responding to strategic objectives and attending to the systems
Ano: 2022
Autor(es): Jorge, C.
Keywords: Wastewater systems; Water-energy-greenhouse gas emissions nexus; Performance assessment; Energy efficiency; Energy balance
Info
Understanding Flow Dynamics in Drinking Water Storage Tanks
Drinking water storage tanks are essential components of water supply systems to store water, to level off pressure in networks and to meet emergency storage. They are also frequent sources of deterioration of drinking water quality and safety owing to inadequate tank design and operation. Mostly, existing tanks design, dimensions and operation do not account for water mixing and renewal.
Ano: 2022
Autor(es): Pinheiro, A.
Keywords: Chlorine decay.; Particle image velocimetry; Residence time distribution; Drinking water safety; Water storage tanks
Info
Assessing the contribution of Nature-Based Solutions to urban resilience. A comprehensive assessment framework with focus on stormwater management and control.
Nature-Based Solutions (NBS) are crucial to achieving the goals of the United Nations Agenda 2030 for sustainable development and other global agendas, such as the Paris Agreement on Climate Change. In the last decade, the NBS umbrella concept has become more relevant intending to contribute to urban resilience and to address the climate change challenges. NBS are living solutions inspired by nature that use or mimic natural processes intending to face several societal challenges, from the perspective of resource-efficient use and the promotion of economic and environmental benefits. Currently, cities are encouraged to understand and measure the NBS contribution to identify adequate strategies for enhancing resilience and prioritize investments accordingly. The objective of the present thesis is to promote and enhance the NBS implementation in cities, focused on solutions for stormwater management and control. Based on the analysis of their contribution to urban resilience, the potential to meet environmental, social, and economic challenges and to adapt across diverse urban scales and contexts is demonstrated. In this sense, a Resilience Assessment Framework (RAF) to assess the NBS contribution to urban resilience was developed. This framework aims to assess the NBS contribution to urban resilience. Moreover, a Guidance for the RAF application in cities with different resilience maturity was developed, which involved the RAF validation by seven cities (from a national and international context), that participated voluntarily in this phase. In this context, the developed RAF is comprehensive and multidimensional. It is driven by the definition of objectives, criteria, and metrics, according to the proposed structure for assessing the water supply and wastewater system service performance in the framework of the ISO 24500 standards of the International Organization for Standardization. For an oriented assessment of the criteria, qualitative and quantitative metrics were defined, considering data from different sources and complexity. Reference values were also identified and metrics' classifications were defined. In this classification, each answer is associated with a resilience development level, intending to assess the NBS contribution to urban resilience on a normalized scale. To support the RAF application to cities with different resilience maturity (in terms of resilience and available information), three analysis degrees (essential, complementary, and comprehensive) and a set of metrics were proposed, which are pre-defined in the guidance for the RAF application. To support the selection of the analysis degree more adequate to any city, a structure to characterize the city's profile was developed. This complementary profile also supports the interpretation of the RAF results, both at the city and at the level of specific NBS. To conclude, the application of the RAF essential analysis degree to the seven participating cities, with different challenges regarding urban resilience and NBS, and of the comprehensive analysis degree (complete RAF) to Porto´s urban area, through an assemble assessment at the city and NBS levels, were presented.
Ano: 2021
Autor(es): Beceiro, P.
Keywords: Urban resilience; Stormwater management; Resilience assessment framework; Nature-Based Solutions (NBS)
Info
Proposal and validation of a performance assessment framework for urban storm water systems
Over the past two decades, performance assessment (PA) has been one of the areas show-ing the greatest advancement in the water sector. PA aims to measure effectiveness and/or efficiency of an activity or process using performance metrics, supporting the decision-making process and the continuous improvement of water utilities. Despite the potential benefits, few projects, and initiatives on PA have been undertaken regarding storm water systems (SWS). The present thesis aims to develop a performance assessment framework (PAF), applicable to both conventional SWS and sustainable urban drainage systems (SUDS), objective driven and focused on systems
Ano: 2021
Autor(es): Santos, L.F.
Keywords: Water utilities; Storm water systems; Indicators; Performance metrics; Framework; Performance assessment
Info
Towards a better urban water infrastructure asset management by condition assessment and cost modelling
Infrastructure asset management (IAM) has been increasingly becoming a key topic in the mind-set shift of the water sector managers and policy makers, allowing to assist in the operational, tactical and strategic decision-making in urban water infrastructures. Nevertheless, IAM implementation by the water utilities is still far from needed and not widespread, due to several challenges and constraints, mainly associated with limited human, technological and financial resources. The current research aims at enhancing urban water infrastructure asset management through an integrated decision-making approach, that includes novel methodologies for condition assessment, service life prediction and cost modelling. This approach can be applied at three assessment levels
Ano: 2021
Autor(es): Cabral , M.
Keywords: Urban water assets; Decision-making; Cost modelling; Service life prediction; Condition assessment; Infrastructure asset management
Info
Melhoria na eficiência no uso da água e da energia em sistemas de abastecimento de água
Este trabalho tem como objetivo melhorar a eficiência energética dos sistemas de abastecimento de água através do desenvolvimento de uma metodologia orientada por objetivos e com recurso ao balanço energético e a métricas de desempenho que permitem identificar as principais origens de ineficiência energética dos sistemas, comparar diferentes alternativas de intervenção e contribuir para a melhoria contínua destes sistemas.A metodologia de investigação seguida contempla desenvolvimentos científicos aliados a uma aplicação prática num conjunto alargado de casos de estudo através de ferramentas de cálculo automático desenvolvidas para o efeito. Os desenvolvimentos científicos consistem na formulação matemática de um balanço energético flexível em termos de dados necessários para a sua implementação; o desenvolvimento de métricas de desempenho que permitem identificar a origem das ineficiências energéticas (equipamentos, perdas de água ou configuração e operação) e a sua sistematização numa metodologia que segue os princípios de melhoria contínua (Plan-Do-Check-Act). A aplicação a casos de estudo é efetuada em três etapas. A primeira etapa consiste na aplicação do balanço energético agregado e métricas de desempenho para diagnosticar ineficiências a nível global em sistemas sem modelo matemático. A segunda etapa consiste na aplicação de um balanço detalhado com recurso a modelos matemáticos, bem como uma análise de sensibilidade aos diferentes métodos. A terceira etapa centra-se na aplicação detalhada de dois casos de estudo para ilustrar a metodologia.Os principais resultados são: i) uma metodologia integrada para o diagnóstico água-energia em sistemas de abastecimento de água; ii) um novo balanço energético para sistemas de abastecimento de água; iii) resultados da aplicação do balanço e das métricas de eficiência energética em 110 sistemas; iv) ferramentas para cálculo das diferentes formulações de balanço energético e de métricas de desempenho; e v) valores reais e exemplos de soluções não convencionais que conduziram a melhorias de desempenho energético.
Ano: 2019
Autor(es): Mamade, A.
Keywords: Sistemas de abastecimento de água; Indicadores de desempenho; Balanço energético; Eficiência energética; Nexo água-energia
Info
Assessing and improving wastewater treatment performance. A contribution to the 3rd generation of the assessment system
As estações de tratamento de águas residuais (ETAR) são atualmente alvo de esforços de melhoria do seu desempenho técnico, ambiental e económico. Empresas, reguladores e organismos de financiamento têm utilizado sistemas de avaliação de desempenho para apoiar as suas decisões. Neste contexto, o LNEC desenvolveu a 1.ª e 2.ª geração do sistema de avaliação de desempenho (PAS) de ETAR baseado em indicadores (PIs) e índices de desempenho (PXs). Para ambos, os valores de referência para o julgamento do desempenho são elementos chave. Apesar de serem elementos cruciais, os valores de referência precisavam ainda de ser definidos para avaliar e melhorar o desempenho das ETAR com foco na eficiência energética e gestão de afluências pluviais. Assim, o objetivo da tese foi desenvolver a terceira geração do PAS com valores de referência para avaliar o desempenho. Os PIs e PXs focam os objetivos principais da ETAR, ou seja, garantir a sustentabilidade técnica, econômica e ambiental, garantindo um tratamento eficaz e fiável com o consumo mínimo de energia, reagentes e produção de lamas. A estratégia seguida consistiu em desenvolver ou selecionar a partir da segunda geração do PAS sub-conjuntos de PIs e PXs de acordo com os objetivos, nomeadamente, eficácia, fiabilidade, desempenho energético e consumo de reagentes e gestão das lamas. Os valores de referência foram derivados com base numa revisão da literatura, equações empíricas e/ou estudos de campo e, sempre que aplicável, incorporam o efeito de parâmetros chave, de modo a avaliar o efeito das variações de caudal e de concentração. Foi desenvolvida uma análise estatística dos PXs para avaliar a fiabilidade da ETAR. Foi também demonstrada a flexibilidade do sistema de avaliação de desempenho para diferentes objetivos e uma abordagem para diagnosticar oportunidades de melhoria do desempenho, utilizando os PIs e PXs num ciclo PDCA (plan-do-check-act).
Ano: 2016
Autor(es): Silva, C.
Keywords: WWTP; Reference values; Performance indices; Performance indicators; Performance assessment
Info
Avaliação e controlo da eficiência do tratamento de águas residuais - Aplicação a sistemas de pequena dimensão
Assiste-se, actualmente, a uma exigência crescente nos requisitos de qualidade das descargas de efluentes urbanos no meio hídrico receptor e, em paralelo, a uma maior pressão no sentido do aumento da eficiência na operação de ETAR, no que diz respeito ao consumo energético e de outros recursos. O objectivo principal da presente dissertação é o desenvolvimento de uma metodologia de monitorização, supervisão e controlo da eficiência do tratamento de águas residuais, adaptada especificamente a pequenas ETAR descentralizadas. Esta metodologia pode definir-se como um conjunto de estratégias de optimização baseadas, grandemente, na aquisição em linha de dados do processo e sua posterior utilização num modelo matemático para definição de cenários operacionais. Para além da metodologia, as principais contribuições inovadoras são a realização, durante um ano, de trabalho de monitorização num sistema de tratamento descentralizado, a utilização de métodos alternativos de monitorização de águas residuais e o desenvolvimento de um modelo matemático para a simulação do comportamento dinâmico de uma ETAR de pequena dimensão. O envolvimento do utilizador final constitui, igualmente, um aspecto importante do presente trabalho, o qual pretende lançar questões e vias de desenvolvimento para as entidades gestoras implementarem processos sustentados de optimização da operação em ETAR descentralizadas.
Ano: 2011
Número Páginas:
278p.
Autor(es): Ribeiro, R.
Keywords: Controlo; Modelação matemática; Monitorização; Lamas activadas; Sistemas descentralizados; Tratamento de águas residuais
Info
Metodologias de Análise de Consumos para a Gestão Eficiente de Sistemas de Distribuição de Água
Este trabalho de investigação teve como objectivo principal propor, aplicar e validar uma metodologia que permitisse transformar dados de consumo urbano de água, obtidos a partir de sistemas de telemetria, em informação útil para a gestão dos serviços de água e para os consumidores.A metodologia encontra-se estruturada em quatro módulos: planeamento e monitorização,processamento de dados, produção de informação de caracterização e previsão eclassificação. Tirando partido de dados de consumo telemedidos aos vários níveis, desde o cliente individual às zonas de medição e controlo (ZMC), procede-se à aplicação dametodologia para caracterização de grandes consumidores, previsão do consumodoméstico nocturno, avaliação do efeito da variação de pressão no consumo autorizado enas perdas de água e previsão do consumo em ZMC.Para além da metodologia estruturada para a análise de consumos, as principaiscontribuições inovadoras são o desenvolvimento de modelos de previsão e de classificação do consumo em ZMC, em função das variáveis explicativas mais significativas, e a obtenção de expressões para a variação do consumo autorizado e das perdas reais com a pressão.O trabalho desenvolvido contribuirá para um uso mais eficiente da água, através de ummelhor conhecimento sobre as várias componentes do consumo urbano de água, assimcomo para o estabelecimento de critérios de projecto e de exploração da rede maissustentados.
Ano: 2010
Número Páginas:
434p.
Autor(es): Loureiro, D.
Keywords: Perdas de água; Zona de medição e controlo; Telemetria; Uso eficiente da água; Consumo urbano de água; Sistema de abastecimento de água
Info
Avaliação de desempenho de estações de tratamento de água para consumo humano
Os serviços de abastecimento de água (SAA) têm vindo a incorporar princípios desustentabilidade na sua prática de gestão. O estado da arte em metodologias de avaliação dedesempenho de SAA mostrou a necessidade de abordar especificamente o tratamento,considerado insatisfatoriamente nas abordagens sistematizadas existentes.Na presente dissertação desenvolveu-se um sistema de avaliação de desempenho (PAS) deestações de tratamento de água (ETA), orientado por objectivos, normalizado e quantitativo,destinado a apoiar a tomada de decisão, e cobrindo os domínios qualidade da água tratada,eficiência/fiabilidade, utilização de água, energia e materiais, gestão de subprodutos, segurança,recursos humanos e económico financeiros.O PAS integra uma componente para avaliação do desempenho global, baseada em indicadoresde desempenho, e uma componente para avaliação do desempenho operacional, baseada emíndices de desempenho que avaliam, numa escala 0-300, a qualidade da água tratada, eficiênciasdas várias operações/processos unitários (OPU) e sua relação com condições de operação.Foi desenvolvida uma ferramenta de cálculo automático do PAS.A aplicação do PAS a cinco ETA de características diversas permitiu avaliar a evoluçãotemporal do seu desempenho, comparar estações e OPU, e identificar oportunidades de melhoriana operação das OPU, na qualidade da água tratada e utilização de recursos.
Ano: 2009
Autor(es): Vieira, P.
Keywords: Tratamento de água para consumo humano; Ferramenta de apoio à decisão; Operação de eta,; Índice de desempenho; Indicador de desempenho; Avaliação de desempenho
|
|
Relatórios
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #11.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #11 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #12.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #12 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #2.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #2 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #3.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #3 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #4.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #4 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #5.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #5 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #6.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #6 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #7.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #7 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #8.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #8 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
Info
Metodologia de auditoria de eficiência hídrica em edifícios de habitação. Relatório final da aplicação ao caso de estudo #9.
O presente documento faz parte do produto D3 da fase 3 do estudo Metodologia de auditoria e classificação hídrica de edifícios residenciais realizado para a ADENE. Constitui o relatório individual final da aplicação da metodologia ao caso de estudo #9 levada a cabo pelo LNEC. Reporta-se a realização das auditorias realizadas nas fases 2 e 3 do estudo e incluem-se os resultados finais obtidos com a versão da metodologia MA2.
Ano: 2019
Autor(es): Vieira, P.; Alegre, H.
Keywords: Auditoria; Eficiência hídrica
|
|
|
Outros
Info
Reutilização potável direta de água pela indústria
Este estudo visa aumentar a confiança na reutilização segura da água, utilizando tecnologias de tratamento avançado como ultrafiltração, ozonização e osmose inversa para avaliar a sua eficácia e limitações. Desenvolvido numa estação de tratamento de águas residuais (ETAR), o estudo comparou a qualidade da água resultante de processos em grande escala, como a ultrafiltração, com água tratada adicionalmente através de um sistema piloto de ozonização e osmose inversa, ou apenas osmose inversa. Todos os esquemas de tratamento estudados produziram água adequada ao consumo humano.
Ano: 2024
Autor(es): Viegas, R.M. C.; Mesquita, E.; Figueiredo, D.; Lourinho, R,; Rosa, M. J.
Keywords: Produção de cerveja; Tratamento avançado de água; Osmose inversa; Processos de membranas; Reutilização potável direta
Info
AWARE-P vence prémio alemão e conquista novo reconhecimento internacional
EXCLUSIVO: AWARE-P vence prémio alemão e conquista novo reconhecimento internacional: É a primeira vez que é distinguido um projecto de um país que não fala alemão, entrevista de Ana Santiago (Jornalista do Jornal Água & Ambiente - Portal Ambiente Online) a Helena Alegre, 19 de Agosto de 2014
Ano: 2014
Número Páginas:
1.
Autor(es): Alegre, H.
Info
Processos de pré oxidação e de desinfeção
N/A
Ano: 2014
Número Páginas:
36 slides.
Autor(es): Rosa, M. J.
Editor: APDA
Info
Vamos premiar quem aproveitou melhor a tecnologia
N/A
Ano: 2014
Número Páginas:
1p.
Autor(es): Alegre, H.
Editor: Ambiente on-line
Info
Ciência e inovação
N/A
Ano: 2012
Número Páginas:
1p.
Autor(es): Alegre, H.
Editor: About Media
Info
A engenharia sanitária no DHA em 2023
N/A
Ano: 2009
Autor(es): Alegre, H.
Info
Aplicações do modelo SWMM a casos de Estudo.
N/A
Ano: 2009
Autor(es): Brito, R. S.; David, L. M.
Info
Modelação dinâmica de sistemas de drenagem: Casos de estudo nacionais
N/A
Ano: 2009
Autor(es): Ferreira, F.; David, L. M.; Brito, R. S.
Info
Modelação dinâmica de sistemas de drenagem: Princípios de modelação e principais modelos existentes
N/A
Ano: 2009
Autor(es): Ferreira, F.; David, L. M.; Matos, J. S.
Info
Modelação estatística do consumo nocturno doméstico de água
N/A
Ano: 2009
Autor(es): Borba, R.; Amado, C.; Pacheco, A.; Loureiro, D.; Rebelo, M.; Alegre, H.; Coelho, S. T.; Covas, D.; Pina, A.
|