Artigos de Revista
Info
Global and local geometrical imperfections of pultruded GFRP profiles based on a modal approach
ABSTRACT - The ultimate capacity of pultruded glass fibre reinforced polymer (pGFRP) profiles depends significantly on geometrical imperfections (GIs), given their sensitivity to buckling phenomena arising from both thin walls and low elastic moduli. However, GIs are not yet comprehensively addressed in design guidance. This paper proposes a new approach to characterize the initial GIs of pGFRP profiles based on a modal approach. Given the lack of comprehensive knowledge in this area, this study presents a highly accurate and robust methodology to measure GIs and dimensional deviations (DDs) in pGFRP profiles using a 3D contact coordinate measurement machine (CMM). The modal approach encompasses the measurement of dimensional parameters and a point cloud transformation that enables the assessment of GIs associated with pure buckling modes of pGFRP profiles. This procedure allows the quantification of three types of global GIs associated to (i) minor-axis (weak axis), (ii) major-axis (strong axis) bending, and (iii) twist. Additionally, the procedure also includes the assessment of local GIs, considering the wall (plate-like) imperfections. The separation of GIs into these four types (shape and amplitude) is of major relevance as its paves the way to the development of analytical design formulas for the strength prediction of pGFRP members. The approach described in this paper also serves two important purposes: (i) the statistical analysis of DDs and GIs of pGFRP members, and (ii) the identification of distinct shapes and amplitudes of GIs that form the basis for reliable design considerations of pGFRP members.
Ano: 2024
Número Páginas:
18p..
Autor(es): Silvestre, N.; Correia, J.; Pinheiro, A.; Ribeiro, A.; Lages Martins, L.; Lazzari, J.
Revista: Construction and Building Materials
Editor: ELSEVIER
Volume:
412 (2024) 134813.
Keywords: Modal decomposition; Geometrical imperfections; Dimensional deviation; 3D contact measurements; Pultruded profiles; Glass fibre reinforced polymer (GFRP)
Info
Metrological quality of the excitation force in forced vibration test of concrete dams
Abstract. This paper describes the study of the metrological quality of the excitation force in the context of force vibration test of concrete dams. For this purpose, a measurement uncertainty evaluation was performed, based on available probabilistic information about the input quantities
Ano: 2024
Autor(es): Lages Martins, L.; Gomes, J. P.; Ribeiro, A.
Revista: Journal of Physics
Editor: IOP Publishing
Volume:
vol. 2647.
Info
Validation of a Iaboratory method for the traceability of a rainfail weighing gauge
ABSTRACTThis study aims to develop a Iaberatory method for the traceability of a rainfali weighing gauge, including an evaluation of the measurement uncertainty. The adopted procedure is similar to the one used for the non-automatic weighing instruments. A static approach is followed to achieve the caiibration deviation of the precipitation scale. The method used te evaluate the measurement uncertainty is based on a nonlinear mathematical model. The Monte Cano method is used to calculate uncertainties and validate estimates following the convencional Guide te the Expression of Uncertainty in Measurement (GUM) approach. Measurementuncertainty contributions of input quantities te the mathematical model used to calculate rainfail also require specific calibrationprocedures. Results show the
Ano: 2024
Número Páginas:
6p..
Autor(es): Simões, C.; Ribeiro, A.; Almeida, M. C.; Covas, D.; Dias, L.; Coelho, G.
Revista: Actas IMEKO, Secção Researchpaper
Editor: University of Calabria
Volume:
Volume 13, Number 1.
Keywords: uncertainly; traceability; Rainfall weighing gauge
Info
A numerical study of measurement uncertainties for wave gauges
This study describes the development of a Monte Carlo based numerical analysis method to determine the instrumental uncertainty of dimensional measurements with wave gauges. The paper presents the adopted calculation procedure, namely, the mathematical model used in the determination of the amplitude and fre-quency of the wave gauge measurements. The results show a relative expanded (95%) target instrumental measurement uncertainty between 0.067 7 m and 0.068 2 m for the amplitude and between 0.592 4 Hz, and 0.592 8 Hz for the frequency. The study carried out allows for the conclusion that the use of a Monte Carlo-based numerical approach is suitable to evaluate the measurement uncertainty of parameters fitted to wave displacement analysis.
Ano: 2021
Número Páginas:
5p.
Autor(es): Coelho, G.; Ribeiro, A.; Neves, M. G.; Pascoal , A.
Revista: Measurement: Sensors
Editor: Journal Elsevier
Volume:
18.
Keywords: Instrumental target measurement uncertainty; Physical modelling; Wave measurement; Wave gauges
Info
Role of measurement uncertainty in the comparison of average areal rainfall methods
Abstract The main motivation for this research is the growing awareness of the impact of climate change and the increasing relevance of the United Nations Sustainable Development Goals, aiming to contribute to the measurement of quantities like precipitation and rate of rainfall. This knowledge is widely used in hydrology, climatology and meteorology, providing data and information applied in modelling, pattern definition and recognition, and forecasting. This work is concerned with estimating the average areal rainfall in a stipulated region from rainfall intensity observations made at measurement stations within that region. It focuses on three straightforward estimation approaches: the arithmetic mean method, the Thiessen polygon method and the isohyetal method. The evaluation of the associated measurement uncertainty, for which the law of propagation of uncertainty and a Monte Carlo method as described in guidance documents from the Joint Committee for Guides in Metrology are applied, is the main consideration. The approaches described may be readily applied by practitioners. A comparison of results from applying these methods to a simple example is made. Such results are required for conformity assessment and support in urban management and water resources management worldwide.
Ano: 2021
Número Páginas:
11p.
Autor(es): Ribeiro, A.; Almeida, M. C.; Cox, M. G.; Sousa, J. A.; Lages Martins, L.; Loureiro, D.; Brito, R.; Soares, A.C.
Revista: Metrologia, MATHMET 2019
Editor: BIPM & IOP Publishing Ltd
Volume:
Volume 58, Number 4 MATHMET 2019.
Keywords: measurement uncertainty; measurement model; average areal rainfall; rainfall intensity
Info
Assessment of the metrological performance of seismic tables for a QMS recognition
Abstract. Seismic testing and analysis using large infrastructures, such as shaking tables and reaction walls, is performed worldwide requiring the use of complex instrumentation systems. To assure the accuracy of these systems, conformity assessment is needed to verify the compliance with standards and applications, and the Quality Management Systems (QMS) is being increasingly applied to domains where risk analysis is critical as a way to provide a formal recognition. This paper describes an approach to the assessment of the metrological performance of seismic shake tables as part of a QMS recognition, with the analysis of a case study of LNEC Seismic shake table.
Ano: 2017
Número Páginas:
6p.
Autor(es): Ribeiro, A.; Campos Costa, A.; Candeias, P.; Sousa, J.; Lages Martins, L.; Soares, A. C.; Costa Ferreira, A.
Revista: Journal of Physics: Conference Series 772 (2016) 012006
Editor: IOP Publishing Ltd
Volume:
Proceedings: https://iopscience.iop.org/issue/1742-6596/772/1.
Keywords: Metrological performance; QMS recognition; Seismic tables
Info
Medição do movimento de abertura-fecho e deslizamento de juntas em barragens de betão
Nesta comunicação, é promovida uma breve descrição dos processos manual e automático para a medição do movimento de juntas em barragens de betão num horizonte temporal alargado que, em regra, abrange vários anos, permitindo conhecer o efeito das solicitações a que está sujeita, em particular a variação térmica ambiental e a evolução do nível de águia na albufeira. o estudo desenvolvido está centrado: (i) na identificação e na quantificação das componentes de incerteza associadas a cada tipo de medição, abrangendo as vertentes do método, instrumento e operador, no caso de medição manual; (ii) na respetiva propagação para as grandezas de interesse (movimento de abertura-fecho e deslizamento); (iii) e na respetiva análise de sensibilidade. Por último, é efetuada a aplicação ao caso real da observação da barragem do Alto Lindoso, onde os resultados obtidos contribuíram para a melhoria da análise comparativa da evolução dinâmica das estimativas obtidas por vias instrumentais distintas.
Ano: 2017
Número Páginas:
13p.
Autor(es): Lages Martins, L.; Ribeiro, A.; Mata, J.; Tavares de Castro, A.
Revista: Revista Medições e Ensaios
Editor: Sociedade Portuguesa de Metrologia
Volume:
N.º 14.
Info
The influence of thermal comfort on the quality of life of nursing home residents
N/A
Ano: 2017
Número Páginas:
11p.
Autor(es): Mendes , A.; Papoila, A .; Carreiro-Martins, P.; Aguiar, L.; Bonassi, S.; Caires , I.; Palmeiro, T.; Ribeiro, A.; Neves, P.; Pereira. C.; Botelho, A.; Neuparth, N.; Teixeira, J.
Revista: Journal of Toxicology and Environmental Health, Parte A
Editor: Taylor & Francis
Info
Traceability of high focal length cameras with diffractive optical elements
Abstract. This paper describes the use of diffractive optical elements (DOEs) for metrological traceable geometrical testing of high focal length cameras applied in the observation of large-scale structures. DOEs and related mathematical models are briefly explained. Laboratorial activities and results are described for the case of a high focal length camera used for long-distance displacement measurement of a long-span (2278 m) suspension bridge.
Ano: 2017
Número Páginas:
6p.
Autor(es): Lages Martins, L.; Ribeiro, A.; Sousa, J.
Revista: Journal of Physics: Conference Series 772 (2016) 012005
Editor: IOP Publishing Ltd
Volume:
Conference Series 772 (2016) 012005.
Keywords: Mathematical models; High focal length cameras; DOEs
Info
The evaluation of uncertainty in mass calibration: Possible approaches in a comparison study
N/A
Ano: 2014
Número Páginas:
7pp.
Autor(es): Sousa, J.; Forbes, A. B.; Ribeiro, A.; Harris, P. M.; Carvalho, F.; Bacelar, L.
Revista: Journal of Physics
Volume:
Conference Series 459 (2013) 012033.
|
Comunicações
Info
Influence of rainfall time series sample rate in the improvement of decision-making based on high intensity rainfall events
Abstract - This study aims Lo assess whether data acquisition frequency can affect the understanding of high-intensity precipitation events. Time series from a weighing gauge and a weighhridge gauge installed at the sarne site were analysed, with rainfall intensity data acquisition frequencies of 10 seconds and 5 minutes, respectively. To check the consistency of the data ohtained by the two types of rainfall measuring instruments, a correlation analysis was carried out between the two time series.The results relating to acquisition frequency showed that, for an acquisition frequency of 5 minutes. there are significant losses of information (especially during heavy rainfall events) compared to acquisition frequencies of l0 seconds. The correlation analysis showed that the gauges are measuring correctly and that the data is accurate.
Ano: 2024
Número Páginas:
8p..
Autor(es): Simões, C.; Ribeiro, A.; Almeida, M. C.; Covas, D.; Coelho, G.; Pinheiro, A.
Editor: XXIV IMEKO Congress "Think Metrology"
Keywords: high-intensity rainfall event; sampling rate; time series data; rainfall
Info
RASTREABILIDADE METROLÓGICA DE EXTENSÓMETROS DE RESISTÊNCIA ELÉTRICA UTILIZADOS NA MONITORIZAÇÃO DE BARRAGENS DE BETÃO
Esta comunicação descreve o processo de garantia da rastreabilidade metrológica dos extensómetros de resistência elétrica do tipo Carlson utilizados na monitorização de barragens de betão. Este processo foi desenvolvido pelo LNEC desde a fase inicial da conceção, produção e caraterização metrológica do padrão de medição itinerante, até à fase final da sua utilização em obra para calibração in situ dos extensómetros antes da sua instalação. É igualmente considerada a propagação das incertezas de medição identificadas nas diferentes fases deste processo, tendo em conta os modelos matemáticos aplicados na determinação da grandeza extensão
Ano: 2019
Número Páginas:
10p.
Autor(es): Lages Martins, L.; Mata, J.; Serra, C.; Ribeiro, A.; Tavares de Castro, A.
Revista: Atas do 2º Congresso de Ensaios e Experimentação em Engenharia Civil
Editor: Atas do 2º Congresso de Ensaios e Experimentação em Engenharia Civil
Info
A Comparision Study on the Uncertainty Evaluation for the Determination of Total Nitrogen, Using ISO 11352 and other Alternative Approaches
N/A
Ano: 2014
Número Páginas:
2pp.
Autor(es): Sousa, J.; Reynolds, A. M.; Ribeiro, A.
Info
Calibration Analysis of a Computational Optical System Applied in the Dimensional Monitoring of a Suspension Bridge
N/A
Ano: 2014
Número Páginas:
8pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Keywords: Displacement; Suspension bridge; Computational vision; Optical metrology
Info
Quality Assessment of Vertical Angular Deviations for Photometer Calibration Benches
Lighting, both natural and electric, constitutes one of the most important aspects of the life ofhuman beings, allowing us to see and perform our daily tasks in outdoor and indoor environments. The safety aspects of Iighting are self-evident in areas such as road Iighting, urban Iighting and also indoor Iighting. The use of photometers to measure lighting leveIs requires traceability obtained in accredited laboratories, which must provide an associated uncertainty. It is therefore relevant to study the impact of known uncertainty sources Iike the vertical angular deviation of photometer calibration benches, in order to define criteria to its quality assessment.
Ano: 2014
Número Páginas:
7pp.
Autor(es): Ribeiro, A.; Santos, A. J.; Sousa, J.; Forbes, A. B.
Info
Structural Observation of Long-span Suspension Bridges for Safety Assessment: Implementation of an Optical Displacement Measurement System
This pape r addresses the implementation of an optical displacement measurement system in the observation scenario of a long-span suspension bridge and its contribution for structural safety assessment. The metrological background required for quality assurance ofthe measurements is described, namely, the system's intrinsic parameterization and integration in the SI dimensional traceability chain by calibration, including its measurement uncertainty assessment.
Ano: 2014
Número Páginas:
6pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Info
Optical measurement system applied to continuous displacement monitoring of long-span suspension bridges
This paper provides a general deseription of main issues related to the design of an optieal measurement system applied to continuous displacement monitoring of long-span suspension bridges. The proposed system's architecture is presented and its main components - camera and active targets - are described in terms of geometrical and radiometric characteristics required for long distance measurement of the tridimensional displaeement of the stiffness girder in the middle section ofthe bridge's central span. The intrinsic and extrinsic camera parameterization processes, which support the adopted measurement approach, are explained in a specific section. Since the designed measurement system is intended to perform eontinuous displaeement monitoring in long distance observation framework, particular attention is given to environmental effects, namely, refraction, turbulence and sensor saturation phenomena, which can influence the displacement measurement accuracy. Finally, a measurement uncertainty method is discussed in order to provide a suitable solution for the determination ofthe accuracy related to the proposed measurement approach.
Ano: 2013
Número Páginas:
8pp.
Autor(es): Lages Martins, L.; Ribeiro, A.; Rebordão, J.
Keywords: Suspension bridge structural monitoring; Displacement optical measurcment
Info
Thermal Comfort Study in Portuguese Elderly Care Centers
Thermal environment in homes does not usually cause serious illness however it has a very significant impact on the general well-being and daily performance of its residents. Poor thermal environment can also aggravate the impact of air pollutants on occupant 's health. This study was performed in 71 elderly care centers rooms both in winter and summer season. Thermal comfort parameters were measured following ISO 7730:2005, included relative humidity (RH), temperature and air velocity in order to determine predicted mean vole (PMV) and predicted percent of dissatisfied people (PPD) indexes. Mean radiant temperature, PMV and PPD indexes and the respective measurement uncertainties were calculated by Monte Carlo Method. The analyzed elderly care centers were naturally ventilated with no cooling systems apart from some passive measures, such as blinds and curtains on the windows. Our results point out that, due to poor insulation, the winter season TC parameters and indexes are not within the class A of ISO 7730:2005 reference (PMV: [-0.2; 0.2]; PPD: < 6 %). Also there are significant differences by season between PPD (P = 0.033) and PMV (P = 0.001) indexes when assessing the same rooms. ln natural ventilated environments with poor insulation, the maintenance of a comfortable indoor environment for elderly populations can be a substantial challenge, especially in winter season.
Ano: 2013
Número Páginas:
6pp.
Autor(es): Mendes , A.; Mendes, D.; Aguiar, L.; Pereira, C.; Neves, M.; Teixeira, J.; Ribeiro, A.
Keywords: Elderly quality of life; Elderly care centers; Predicted percent of dissatisfied; Predicted mean vote; Thermal comfort
Info
Evaluation of measurement uncertainty in tests requiring non-linear regression
N/A
Ano: 2012
Número Páginas:
6.
Autor(es): Sousa, J.; Forbes, A. B.; Ribeiro, A.; Sousa, D.; Smith, I.
Keywords: Least squares adjustment; Modelling; Non-linear regression; Uncertainty
Info
Measurement quality and uncertainty evaluation in civil engineering research
N/A
Ano: 2012
Número Páginas:
8.
Autor(es): Ribeiro, A.; Sousa, J.; Oliveira Costa, C.; Sousa, J. F.; Almeida Garrett, J.; Lages Martins, L.
Keywords: Civil engineering; Quality; Measurement uncertainty
|
|
Capítulos de Livros
Info
The propagation of urcertainty related to the calibration functions of platinum resistance thermometers and possible correlation effects
THE PROPAGATION OF UNCERTAINTY RELATED TO THE CALIBRATION FUNCTIONS OF PLATINUM RESISTANCE THERMOMETERS AND POSSIBLE CORRELATION EFFECTS A. S. Ribeiro1, J. A. Sousa2, C. O. Costa1, M. G. Cox3, P. M. Harris3 1 National Laboratory of Civil Engineering, 1700-066 Lisbon, Portugal 2 Madeira Regional Laboratory of Civil Engineering, 9000-264 Funchal, Portugal 3 National Physical Laboratory, TW11 0LW Teddington, Middlesex, UK In metrology laboratories, the transfer of traceability from primary standards (fixed points) to standard platinum resistance thermometers (SPRTs) is commonly based on the use of in-house methodologies with the testing points defined by the International Temperature Scale, ITS-90. This process, however, is not simple, since different calibration functions apply to different temperature sub-intervals. The process has two stages: (1) estimation of the calibration parameters of the PRT, and (2) the use of those calibration parameter estimates to obtain temperatures from measured values of electrical resistance. A relevant discussion is whether to use the above two stages or an approach given by combining them, taking into account the correlation associated with estimates of the calibration parameter estimates. In such cases, a further uncertainty component should be evaluated and included in the uncertainty budget. An example of application is given regarding the calibration and use of 25 W SPRTs in a metrology laboratory, considering two overlapping sub-intervals.
Ano: 2009
Número Páginas:
273-278pp.
Autor(es): Ribeiro, A.; Sousa, J. A.; Oliveira Costa, C.; Cox, M. G.; Harris, P. M.
Editor: F. Pavese; M. Bär; A. B. Forbes; J. M. Linares; C. Perruchet; N. F. Zhang
Volume:
Vol. 78.
|
Teses de Doutoramento
Info
Avaliação de incertezas de medição em sistemas complexos lineares e não-lineares
A perspectiva contemporânea da Metrologia evoluiu de uma interpretação clássica, determinística, do problema da medição para uma interpretação moderna, probabilística, percorrendo um trajecto similar ao de outros ramos da ciência. Como consequência desta evolução, os fundamentos da medição sofreram uma importante reestruturação onde ao erro da medição apenas ficou reservado um papel conceptual enquanto que à incerteza da medição foi atribuído o papel fundamental de parâmetro que quantifica o grau de exactidão da estimativa da mensuranda. Esta nova orientação reflecte-se, com particular intensidade, nas actividades desenvolvidas pelos organismos de ciência e tecnologia onde o recurso à medição experimental é uma actividade de natureza transversal. Por esta razão, e pelo menos para estes Organismos, os estudos que visem uma aplicação mais eficaz e abrangente de metodologias para avaliação de incertezas de medição revestem-se de particular interesse. Os Sistemas de Gestão da Qualidade, em rápida expansão, deram à problemática da avaliação das incertezas uma grande visibilidade o que, por sua vez, teve como reflexo uma rápida percepção das limitações e fragilidades da metodologia vigente (GUM). Esta percepção estimulou o estudo e desenvolvimento de soluções alternativas ao GUM para a avaliação das incertezas de medição. A simulação numérica suportada no Método de Monte Carlo (MCS) é uma das soluções alternativas consideradas. No momento actual, os meios computacionais amplamente disponíveis e o vasto conhecimento acumulado sobre a MCS criaram as condições para que esta abordagem possa ser considerada capaz de colmatar as dificuldades existentes. É neste enquadramento que a presente tese procura explorar e aprofundar o conhecimento da metodologia MCS visando superar limitações na avaliação de incertezas de medição onde elas subsistem ou incrementar a qualidade dos resultados, designadamente, em sistemas complexos lineares e não lineares. São de destacar: o estudo das limitações associadas aos requisitos de aplicação das metodologias vigentes (nomeadamente, o ISO-GUM); a caracterização das condições de aplicação da simulação pelo método de Monte Carlo em Metrologia garantindo níveis de robustez, exactidão e fiabilidade elevados; e a evidenciação do potencial da metodologia MCS para a avaliação de incertezas de medição em problemas metrológicos onde as metodologias conhecidas não dispõem de capacidade para a sua resolução, nomeadamente quando os modelos matemáticos em causa possuem relações implícitas, são de natureza complexa ou são fortemente não-lineares.
Ano: 2009
Autor(es): Ribeiro, A.
Keywords: Gerador de números pseudo-aleatórios; Metrologia; Método de monte carlo; Incertezas de medição; Medição
|
|
Relatórios
Info
Procedimento de calibração de dilatómetros diferenciais
O presente relatório apresenta um procedimento de calibração de dilatómetros diferenciais desenvolvido no Centro de Instrumentação Científica do LNEC e realizado pelo Laboratório Central de Apoio Metrológico (LCAM/LNEC) nas instalações do cliente. Este tipo de equipamento de medição é aplicado em ensaios de materiais visando a determinação do respetivo coeficiente de dilatação térmica.
Ano: 2012
Número Páginas:
35pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Info
Procedimento de ensaio de equipamento pendular para ensaios de choque Charpy de materiais metálicos de acordo com a norma de referência EN ISO 148-2: 2008
O presente relatório apresenta um procedimento de ensaio de equipamento pendular para ensaio de choque Charpy de materiais metálicos, de acordo com a norma de referência EN ISO 148-2:2008, desenvolvido no Centro de Instrumentação Científica (CIC) do LNEC e realizado pelo Laboratório Central de Apoio Metrológico (LCAM).
Ano: 2012
Número Páginas:
24pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Info
Revisão das melhores capacidades de medição e de calibração (CMC ) do Laboratório central de apoio Metrológico do LNEC em 2012
O relatório apresenta uma descrição genérica do procedimento de avaliação de incertezas de medição elaborado de acordo com o GUM, a estrutura das tabelas de balanço de incertezas e o quadro de melhores capacidades de medição e de calibração do LCAM/LNEC em 2012, relativas à actividade desenvolvida pelo laboratório no âmbito da sua acreditação no Sistema Português da Qualidade.
Ano: 2012
Número Páginas:
69pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Info
Avaliação de incertezas de medição no Laboratório de Ensaio de Materiais para pavimentação (LNEC/PAVMAT) - Ensaio de determinação da baridade máxima teórica mediante procedimento volumétrico
Este relatório descreve o processo de avaliação de incertezas de medição do ensaio de determinação da baridade máxima teórica de misturas betuminosas realizado pelo Laboratório de Ensaio de Materiais para a Pavimentação do Laboratório Nacional de Engenharia Civil (LNEC/PAVMAT), para o qual é adoptado o procedimento de ensaio volumétrico previsto no respectivo enquadramento normativo. O presente documento contém uma descrição sumária do ensaio estudado apresentando, igualmente, o conjunto de relações funcionais aplicáveis e as tabelas de balanço de incertezas de medição obtidas com base na aplicação do método GUM.
Ano: 2011
Número Páginas:
36pp.
Autor(es): Lages Martins, L.; Ribeiro, A.
Editor: LNEC
Info
Laboratório Central de Apoio Metrológico do Lnec - Evolução, capacidades actuais e potenciais linhas estratégicas de desenvolvimento futuro
A criação do Laboratório Central de Apoio Metrológico (LCAM) do LNEC, em 1993, ocorreu num contexto em que se pretendia desenvolver uma infraestrutura metrológica de apoio a um conjunto de laboratórios com ensaios acreditados. Com a importância crescente da Qualidade, a sua acção desenvolveu-se para outras actividades de I&DI no âmbito da Engenharia Civil onde a medição tem um papel relevante. Para responder às exigências que constituem, na actualidade, a missão do LCAM no seio do LNEC é útil conhecer a sua origem e evolução, as suas capacidades e os desafios emergentes que se afiguram, de modo a perspectivar o seu futuro. O presente relatório apresenta, por isso, os aspectos inerentes a esta evolução, a descrição das suas capacidades actuais e potenciais linhas de desenvolvimento visando a consolidação da sua acção.
Ano: 2011
Número Páginas:
54pp.
Autor(es): Ribeiro, A.
Editor: LNEC
Info
Marshall Calc - Aplicação computacional de processamento de dados do ensaio de compressão Marshall de misturas betuminosas
Este relatório contém uma descrição das etapas de concepção, desenvolvimento e concretização da aplicação computacional Marshall Calc aplicada no processamento de dados obtidos no ensaio de compressão Marshall de misturas betuminosas. Em particular, destacam-se a especificação de requisitos, a ferramenta computacional de suporte, os módulos e suas funcionalidades e a avaliação de qualidade suportada num processo de validação. Adicionalmente, inclui-se uma secção dedicada a manual de utilização, onde se mencionam os aspectos essenciais da sua operacionalidade e manutenção.
Ano: 2011
Número Páginas:
66pp.
Autor(es): Lages Martins, L.; Ribeiro, A.
Editor: LNEC
Info
Procedimento de calibração de medidores de nível (caudal) ultrassónicos
O presente relatório apresenta um procedimento para a calibração de medidores de nível ultrassónicos desenvolvido no Centro de Instrumentação Científica do LNEC e realizado no Laboratório Central de Apoio Metrológico (LCAM/LNEC), cuja aplicação habitual se destina à medição de caudal de escoamentos em superfície livre, nomeadamente, em caleiras Parshall.
Ano: 2011
Número Páginas:
27pp.
Autor(es): Ribeiro, A.; Lages Martins, L.; Benevente, J.
Editor: LNEC
Info
Procedimento de calibração do sistema de medição unidimensional Trimos
O presente relatório apresenta um procedimento de calibração de um sistema de medição unidimensional Trimos desenvolvido no Centro de Instrumentação Científica do LNEC e realizado no Laboratório Central de Apoio Metrológico (LCAM/LNEC). Este equipamento constitui um padrão de transferência do laboratório aplicado na calibração de instrumentos de medição, nomeadamente, comparadores, transdutores de deslocamento e cabeças micrométricas.
Ano: 2011
Número Páginas:
44pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Info
Procedimento de ensaio metrológico de pêndulos Britânicos (medidores de fricção)
O presente relatório apresenta um procedimento de ensaio metrológico de pêndulos britânicos (medidores de fricção) desenvolvido no Centro de Instrumentação Científica do LNEC e realizado no Laboratório Central de Apoio Metrológico (LCAM/LNEC).
Ano: 2011
Número Páginas:
58pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Info
Revisão das melhores capacidades de medição e de calibração do Laboratório central de apoio metrológico do LNEC em 2011
O relatório apresenta uma descrição genérica do procedimento de avaliação de incertezas de medição elaborado de acordo com o GUM, a estrutura das tabelas de balanço de incertezas e o quadro de melhores capacidades de medição e de calibração do LCAM/LNEC em 2011, relativas à actividade desenvolvida pelo laboratório no âmbito da sua acreditação no Sistema Português da Qualidade.
Ano: 2011
Número Páginas:
67pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
|
Informações Científicas e Técnicas
Info
Método de confirmação metrológica de instrumentação científica - Uma abordagem probabilística
A Metrologia constitui um ramo da Ciência com uma aplicação transversal diversificada nos contextos científico, industrial e legal. Em todos eles, a actividade experimental assume um papel preponderante no processo de garantia da qualidade. Na actualidade, uma parte significativa da actividade experimental é desenvolvida no âmbito de Sistemas de Gestão (da Qualidade), os quais impõem requisitos normativos estritos visando a evidenciação objectiva da qualidade dos resultados de medição. Uma vez que a instrumentação desempenha o papel de meio que permite concretizar a medição, e considerando que a sua utilização tem uma finalidade contendo os seus próprios requisitos, a avaliação da qualidade deverá ser baseada numa comparação entre o desempenho metrológico da instrumentação e a exigência de exactidão inerentes a essa finalidade. Na vida útil de um instrumento de medição é observada uma permanente modificação da sua condição metrológica o que justifica a necessidade da sua calibração periódica e determina a necessidade de se promover um acompanhamento da sua evolução de modo a assegurar que essa condição é, em cada momento, adequada à sua aplicação. É neste contexto que se introduz o processo de confirmação metrológica, o qual consiste na aplicação de um método de verificação da conformidade da condição metrológica do instrumento de medição relativamente ao uso pretendido, após a realização de uma calibração. A forma de concretizar esta avaliação não constitui, ainda, um assunto consensual. A divergência mais significativa está relacionada com a definição do critério e dos parâmetros a aplicar, pelo que este documento pretende dar um contributo para a definição de um critério que seja, por um lado, consistente com a actual abordagem probabilística da medição e, por outro lado, adequado face às exigências de boa gestão financeira e patrimonial, em acordo com os objectivos preconizados pela abordagem subjacente aos Sistemas de Qualidade Total.
Ano: 2009
Número Páginas:
70pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Keywords: Avaliação; Incerteza de medição; Garantia de qualidade; Calibração; Instrumento de medição
|
|
|