Artigos de Revista
Info
Thermal Influence on Long-Distance Optical Measurement of Suspension Bridge Displacement
This paper discusses the thermal influence on long-distance and noncontact measurement of suspension bridge three-dimensional displacement by the use of an optical system composed of a digital camera, infrared active targets, and computational support. ln this type of measurement method, the optical propagation path of light through the air can range from 250 m up to 750 m, making its measurement accuracy strongly dependent on atmospheric refraction and turbulence, phenomena that are linked to the vertical temperature gradient between the camera and targets. ln addition, the adopted measurement geometrical configuration can lead to a height difference between these two elements (camera and targets) above 50 m. The paper describes the experimental setup and procedure followed for the determination of local temperature vertical gradients in the 25th of April Bridge in Lisbon (Portugal), where an optical measurement system was applied. The obtained thermal measurements are presented and applied in the evaluation of the systematic refraction vertical deviation, based on appropriate mathematical models mentioned in the paper, and for the identification of stable or unstable observation thermal conditions related to turbulence.
Ano: 2014
Número Páginas:
19pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Revista: International Journal of Thermophysics
Volume:
35.
Keywords: Displacement; Temperature; Suspension bridge; Optical system
Info
Conception and development of an optical methodology applied to long-distance measurement of suspension bridges dynarnic displaccment
N/A
Ano: 2013
Número Páginas:
6pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Revista: Journal of Physics
Volume:
Conference Series 459 (2013) 012055.
Info
Metrologia óptica aplicada à segurança estrutural de pontes suspensas
A presente comunicação descreve as temáticas desenvolvidas no âmbito da conceção e desenvolvimento de um sistema óptico de visão computacional visando a medição do deslocamento tridimensional a V2 vão da viga de rigidez de pontes suspensas. É apresentado o estado da arte no que respeita a sistemas de medição dimensional a longa distância e é mencionada a motivação para o recurso aos sistemas ópticos de visão computacional. Descrevem-se os principais aspetos do método de medição proposto, em particular, os sistemas de compensação da refração atmosférica e do comportamento dinâmico relativo a câmaras e turbulência atmosférica. É, ainda, descrito o processo de simulação numérica visando a validação dos algoritmos de suporte computacional desenvolvidos neste contexto, nomeadamente, no que respeita aos algoritmos de reconhecimento de alvo, parametrização, triangulação e redundância. Finalmente, é exposto o conjunto de atividades experimentais planeadas para a caracterização do sistema óptico de medição proposto mediante ensaio metrológico e calibração com recurso a protótipo de padrão de referência, assegurando-se a rastreabilidade do sistema de medição ao SI de Unidades e o conhecimento do seu nível de exatidão suportado na respetiva avaliação de incertezas de medição.
Ano: 2013
Número Páginas:
03-15pp.
Autor(es): Lages Martins, L.; Ribeiro, A.; Rebordão, J.
Revista: Revista Medições e Ensaios
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
N.º 6.
Info
Sobre o conceito de incerteza em Física e na Metrologia
N/A
Ano: 2013
Número Páginas:
3-13pp.
Autor(es): Ribeiro, A.
Revista: Revista Medições e Ensaios
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
N.º 5.
Info
Viabilidade Técnica e impacto económico da aplicação do método Bootstrap em estudos de repetibilidade e reprodutividade
A repetibilidade e a reprodutibilidade são duas caracteristicas metrológicas que, frequentemente, constituem relevantes contribuições para a incerteza de medição associada aos resultados de ensaios laboratoriais realizados em contexto industrial e técnico-cientifico. A sua quantificação permite uma análise diferenciada e combinada do efeito que os principais fatores intervenientes no processo de medição (designadamente, a instrumentação, o método e o operador) têm na qualidade dos resultados, promovendo a melhoria da qualidade dos processos laboratoriais e industriais e, por essa via, constituir uma ferramenta de apoio para a garantia da qualidade de produtos e serviços. Numa fase inicial, a presente comunicação pretende clarificar a definição destes dois conceitos [1] abordando-se, em seguida, o dimensionamento de ensaios laboratoriais de repetibilidade e reprodutibilidade, comparando a aplicação de métodos estatísticos clássicos (por exemplo, o método ANOVA) [2,3] com a exploração do método de simUlação numérica Bootstrap [4]. procurando avaliar a capacidade destes métodos para garantir resultados com elevado nível de confiança e para reduzir os custos económicos para os laboratórios decorrentes da necessidade de se promover este tipo de ensaios. A aplicação dos métodos acima mencionados é exemplificada em ensaios laboratoriais de medição dimensional sendo efetuada uma comparação de resultados experimentais, suportando a discussão da aplicação da abordagem alternativa constituída pela utilização de método de simulação numérica neste e noutros contextos onde a informação resulta essencialmente das amostras experimentais, como é o caso dos ensaios de comparação interlaboratorial.
Ano: 2013
Número Páginas:
19-29pp.
Autor(es): Lages Martins, L.; Ribeiro, A.
Revista: Revista Medições e Ensaios
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
N.º 5.
Info
A comparision in the evaluation of measurement uncertainty in analytical chemistry testing between the use of quality control data and a regression analysis
N/A
Ano: 2012
Número Páginas:
8p.
Autor(es): Sousa, J. A.; Reynolds, A. M.; Ribeiro, A.
Revista: Accreditation and Quality Assurance - Journal for Quality, Comparability and Reliability in Chemical Measurement
Editor: Springer
Keywords: Gum uncertainty framework; Monte carlo method; Regression analysis; Chemical metrology; Measurement uncertainty
Info
A Qualidade das Medições de Deslocamento Radial e Tangencial pelo Método do Fio-de-prumo no Controlo da Segurança Estrutural de Barragens de Betão
N/A
Ano: 2012
Número Páginas:
32-40 pp.
Autor(es): Lages Martins, L.; Mata, J.; Ribeiro, A.
Revista: Revista da SPMet "Medições e Ensaios"
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
Vol. 1.
Info
Implicações Económicas da Gestão Metrológica da Instrumentação
N/A
Ano: 2012
Número Páginas:
13-19pp.
Autor(es): Ribeiro, A.; Sousa, J.; Sousa, C.
Revista: Revista SPMet "Medições e Ensaios
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
Vol. I.
Keywords: Gestão metrológica; Instrumentação; Eficiência; Confirmação metrológica
Info
Selecção do Método Matemático para Determinação da Tagente no Ensaio de Compressão Marshall, Suportada na Avaliação de Incertezas de Medição
N/A
Ano: 2012
Número Páginas:
3-10pp.
Autor(es): Lages Martins, L.; Ribeiro, A.; Batista, F. A.; Maia, A.; Freire, A. C.
Revista: Revista da SPMet "Medições e Ensaios"
Editor: SPMET - Sociedade Portuguesa de Metrologia
Volume:
Vol. I.
Info
Measurement uncertainties in regression analysis with scarcity of data
N/A
Ano: 2011
Número Páginas:
8p.
Autor(es): Sousa, J. A.; Ribeiro, A.; Cox, M. G.; Harris, P. M.; Sousa, J. F.
Revista: Journal of Physics
Editor: IOP Science
Volume:
Conference Series.
|
Comunicações
Info
Influence of rainfall time series sample rate in the improvement of decision-making based on high intensity rainfall events
Abstract - This study aims Lo assess whether data acquisition frequency can affect the understanding of high-intensity precipitation events. Time series from a weighing gauge and a weighhridge gauge installed at the sarne site were analysed, with rainfall intensity data acquisition frequencies of 10 seconds and 5 minutes, respectively. To check the consistency of the data ohtained by the two types of rainfall measuring instruments, a correlation analysis was carried out between the two time series.The results relating to acquisition frequency showed that, for an acquisition frequency of 5 minutes. there are significant losses of information (especially during heavy rainfall events) compared to acquisition frequencies of l0 seconds. The correlation analysis showed that the gauges are measuring correctly and that the data is accurate.
Ano: 2024
Número Páginas:
8p..
Autor(es): Simões, C.; Ribeiro, A.; Almeida, M. C.; Covas, D.; Coelho, G.; Pinheiro, A.
Editor: XXIV IMEKO Congress "Think Metrology"
Keywords: high-intensity rainfall event; sampling rate; time series data; rainfall
Info
RASTREABILIDADE METROLÓGICA DE EXTENSÓMETROS DE RESISTÊNCIA ELÉTRICA UTILIZADOS NA MONITORIZAÇÃO DE BARRAGENS DE BETÃO
Esta comunicação descreve o processo de garantia da rastreabilidade metrológica dos extensómetros de resistência elétrica do tipo Carlson utilizados na monitorização de barragens de betão. Este processo foi desenvolvido pelo LNEC desde a fase inicial da conceção, produção e caraterização metrológica do padrão de medição itinerante, até à fase final da sua utilização em obra para calibração in situ dos extensómetros antes da sua instalação. É igualmente considerada a propagação das incertezas de medição identificadas nas diferentes fases deste processo, tendo em conta os modelos matemáticos aplicados na determinação da grandeza extensão
Ano: 2019
Número Páginas:
10p.
Autor(es): Lages Martins, L.; Mata, J.; Serra, C.; Ribeiro, A.; Tavares de Castro, A.
Revista: Atas do 2º Congresso de Ensaios e Experimentação em Engenharia Civil
Editor: Atas do 2º Congresso de Ensaios e Experimentação em Engenharia Civil
Info
A Comparision Study on the Uncertainty Evaluation for the Determination of Total Nitrogen, Using ISO 11352 and other Alternative Approaches
N/A
Ano: 2014
Número Páginas:
2pp.
Autor(es): Sousa, J.; Reynolds, A. M.; Ribeiro, A.
Info
Calibration Analysis of a Computational Optical System Applied in the Dimensional Monitoring of a Suspension Bridge
N/A
Ano: 2014
Número Páginas:
8pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Keywords: Displacement; Suspension bridge; Computational vision; Optical metrology
Info
Quality Assessment of Vertical Angular Deviations for Photometer Calibration Benches
Lighting, both natural and electric, constitutes one of the most important aspects of the life ofhuman beings, allowing us to see and perform our daily tasks in outdoor and indoor environments. The safety aspects of Iighting are self-evident in areas such as road Iighting, urban Iighting and also indoor Iighting. The use of photometers to measure lighting leveIs requires traceability obtained in accredited laboratories, which must provide an associated uncertainty. It is therefore relevant to study the impact of known uncertainty sources Iike the vertical angular deviation of photometer calibration benches, in order to define criteria to its quality assessment.
Ano: 2014
Número Páginas:
7pp.
Autor(es): Ribeiro, A.; Santos, A. J.; Sousa, J.; Forbes, A. B.
Info
Structural Observation of Long-span Suspension Bridges for Safety Assessment: Implementation of an Optical Displacement Measurement System
This pape r addresses the implementation of an optical displacement measurement system in the observation scenario of a long-span suspension bridge and its contribution for structural safety assessment. The metrological background required for quality assurance ofthe measurements is described, namely, the system's intrinsic parameterization and integration in the SI dimensional traceability chain by calibration, including its measurement uncertainty assessment.
Ano: 2014
Número Páginas:
6pp.
Autor(es): Lages Martins, L.; Rebordão, J.; Ribeiro, A.
Info
Optical measurement system applied to continuous displacement monitoring of long-span suspension bridges
This paper provides a general deseription of main issues related to the design of an optieal measurement system applied to continuous displacement monitoring of long-span suspension bridges. The proposed system's architecture is presented and its main components - camera and active targets - are described in terms of geometrical and radiometric characteristics required for long distance measurement of the tridimensional displaeement of the stiffness girder in the middle section ofthe bridge's central span. The intrinsic and extrinsic camera parameterization processes, which support the adopted measurement approach, are explained in a specific section. Since the designed measurement system is intended to perform eontinuous displaeement monitoring in long distance observation framework, particular attention is given to environmental effects, namely, refraction, turbulence and sensor saturation phenomena, which can influence the displacement measurement accuracy. Finally, a measurement uncertainty method is discussed in order to provide a suitable solution for the determination ofthe accuracy related to the proposed measurement approach.
Ano: 2013
Número Páginas:
8pp.
Autor(es): Lages Martins, L.; Ribeiro, A.; Rebordão, J.
Keywords: Suspension bridge structural monitoring; Displacement optical measurcment
Info
Thermal Comfort Study in Portuguese Elderly Care Centers
Thermal environment in homes does not usually cause serious illness however it has a very significant impact on the general well-being and daily performance of its residents. Poor thermal environment can also aggravate the impact of air pollutants on occupant 's health. This study was performed in 71 elderly care centers rooms both in winter and summer season. Thermal comfort parameters were measured following ISO 7730:2005, included relative humidity (RH), temperature and air velocity in order to determine predicted mean vole (PMV) and predicted percent of dissatisfied people (PPD) indexes. Mean radiant temperature, PMV and PPD indexes and the respective measurement uncertainties were calculated by Monte Carlo Method. The analyzed elderly care centers were naturally ventilated with no cooling systems apart from some passive measures, such as blinds and curtains on the windows. Our results point out that, due to poor insulation, the winter season TC parameters and indexes are not within the class A of ISO 7730:2005 reference (PMV: [-0.2; 0.2]; PPD: < 6 %). Also there are significant differences by season between PPD (P = 0.033) and PMV (P = 0.001) indexes when assessing the same rooms. ln natural ventilated environments with poor insulation, the maintenance of a comfortable indoor environment for elderly populations can be a substantial challenge, especially in winter season.
Ano: 2013
Número Páginas:
6pp.
Autor(es): Mendes , A.; Mendes, D.; Aguiar, L.; Pereira, C.; Neves, M.; Teixeira, J.; Ribeiro, A.
Keywords: Elderly quality of life; Elderly care centers; Predicted percent of dissatisfied; Predicted mean vote; Thermal comfort
Info
Evaluation of measurement uncertainty in tests requiring non-linear regression
N/A
Ano: 2012
Número Páginas:
6.
Autor(es): Sousa, J.; Forbes, A. B.; Ribeiro, A.; Sousa, D.; Smith, I.
Keywords: Least squares adjustment; Modelling; Non-linear regression; Uncertainty
Info
Measurement quality and uncertainty evaluation in civil engineering research
N/A
Ano: 2012
Número Páginas:
8.
Autor(es): Ribeiro, A.; Sousa, J.; Oliveira Costa, C.; Sousa, J. F.; Almeida Garrett, J.; Lages Martins, L.
Keywords: Civil engineering; Quality; Measurement uncertainty
|
|
Capítulos de Livros
Info
The propagation of urcertainty related to the calibration functions of platinum resistance thermometers and possible correlation effects
THE PROPAGATION OF UNCERTAINTY RELATED TO THE CALIBRATION FUNCTIONS OF PLATINUM RESISTANCE THERMOMETERS AND POSSIBLE CORRELATION EFFECTS A. S. Ribeiro1, J. A. Sousa2, C. O. Costa1, M. G. Cox3, P. M. Harris3 1 National Laboratory of Civil Engineering, 1700-066 Lisbon, Portugal 2 Madeira Regional Laboratory of Civil Engineering, 9000-264 Funchal, Portugal 3 National Physical Laboratory, TW11 0LW Teddington, Middlesex, UK In metrology laboratories, the transfer of traceability from primary standards (fixed points) to standard platinum resistance thermometers (SPRTs) is commonly based on the use of in-house methodologies with the testing points defined by the International Temperature Scale, ITS-90. This process, however, is not simple, since different calibration functions apply to different temperature sub-intervals. The process has two stages: (1) estimation of the calibration parameters of the PRT, and (2) the use of those calibration parameter estimates to obtain temperatures from measured values of electrical resistance. A relevant discussion is whether to use the above two stages or an approach given by combining them, taking into account the correlation associated with estimates of the calibration parameter estimates. In such cases, a further uncertainty component should be evaluated and included in the uncertainty budget. An example of application is given regarding the calibration and use of 25 W SPRTs in a metrology laboratory, considering two overlapping sub-intervals.
Ano: 2009
Número Páginas:
273-278pp.
Autor(es): Ribeiro, A.; Sousa, J. A.; Oliveira Costa, C.; Cox, M. G.; Harris, P. M.
Editor: F. Pavese; M. Bär; A. B. Forbes; J. M. Linares; C. Perruchet; N. F. Zhang
Volume:
Vol. 78.
|
Teses de Doutoramento
Info
Avaliação de incertezas de medição em sistemas complexos lineares e não-lineares
A perspectiva contemporânea da Metrologia evoluiu de uma interpretação clássica, determinística, do problema da medição para uma interpretação moderna, probabilística, percorrendo um trajecto similar ao de outros ramos da ciência. Como consequência desta evolução, os fundamentos da medição sofreram uma importante reestruturação onde ao erro da medição apenas ficou reservado um papel conceptual enquanto que à incerteza da medição foi atribuído o papel fundamental de parâmetro que quantifica o grau de exactidão da estimativa da mensuranda. Esta nova orientação reflecte-se, com particular intensidade, nas actividades desenvolvidas pelos organismos de ciência e tecnologia onde o recurso à medição experimental é uma actividade de natureza transversal. Por esta razão, e pelo menos para estes Organismos, os estudos que visem uma aplicação mais eficaz e abrangente de metodologias para avaliação de incertezas de medição revestem-se de particular interesse. Os Sistemas de Gestão da Qualidade, em rápida expansão, deram à problemática da avaliação das incertezas uma grande visibilidade o que, por sua vez, teve como reflexo uma rápida percepção das limitações e fragilidades da metodologia vigente (GUM). Esta percepção estimulou o estudo e desenvolvimento de soluções alternativas ao GUM para a avaliação das incertezas de medição. A simulação numérica suportada no Método de Monte Carlo (MCS) é uma das soluções alternativas consideradas. No momento actual, os meios computacionais amplamente disponíveis e o vasto conhecimento acumulado sobre a MCS criaram as condições para que esta abordagem possa ser considerada capaz de colmatar as dificuldades existentes. É neste enquadramento que a presente tese procura explorar e aprofundar o conhecimento da metodologia MCS visando superar limitações na avaliação de incertezas de medição onde elas subsistem ou incrementar a qualidade dos resultados, designadamente, em sistemas complexos lineares e não lineares. São de destacar: o estudo das limitações associadas aos requisitos de aplicação das metodologias vigentes (nomeadamente, o ISO-GUM); a caracterização das condições de aplicação da simulação pelo método de Monte Carlo em Metrologia garantindo níveis de robustez, exactidão e fiabilidade elevados; e a evidenciação do potencial da metodologia MCS para a avaliação de incertezas de medição em problemas metrológicos onde as metodologias conhecidas não dispõem de capacidade para a sua resolução, nomeadamente quando os modelos matemáticos em causa possuem relações implícitas, são de natureza complexa ou são fortemente não-lineares.
Ano: 2009
Autor(es): Ribeiro, A.
Keywords: Gerador de números pseudo-aleatórios; Metrologia; Método de monte carlo; Incertezas de medição; Medição
|
|
Relatórios
Info
Procedimento de ensaio metrológico de calorímetros semi-adiabáticos de Langavant no LCAM/LNEC (Versão 1)
O presente relatório apresenta um procedimento para o ensaio metrológico de calorímetros semi- adiabáticos de Langavant elaborado no LCAM/LNEC
Ano: 2008
Número Páginas:
42pp.
Autor(es): Ribeiro, A.; Lages Martins, L.; Benevente, J.
Keywords: De calorímetros semi-adiabáticos de langavant; Ensaio metrológico
Info
Procedimento para calibração de calibradores de extensómetros no LCAM/LNEC (Versão 1)
O presente relatório apresenta um procedimento para a calibração de calibradores de extensómetros elaborado no LCAM/LNEC.
Ano: 2008
Número Páginas:
28pp.
Autor(es): Ribeiro, A.; Lages Martins, L.; Benevente, J.
Keywords: Calibradores; Calibração
Info
Procedimento para calibração de geradores de humidade no LCAM/LNEC (Versão 1)
O presente relatório apresenta um procedimento para a calibração de geradores de humidade elaborado no LCAM/LNEC
Ano: 2008
Número Páginas:
38pp.
Autor(es): Ribeiro, A.; Lages Martins, L.; Benevente, J.
Keywords: Humidade; Geradores
Info
Revisão das melhores incertezas de medição do Laboratório Central de Apoio Metrológico do LNEC em 2008
O relatório apresenta uma descrição do procedimento de avaliação de incertezas de medição de acordo com o GUM, a estrutura das tabelas de balanço de incertezas e o quadro de melhores incertezas de medição do LCAM em 2008, relativas às calibrações e ensaios metrológicos desenvolvidos pelo laboratório no âmbito da sua acreditação no Sistema Português da Qualidade.
Ano: 2008
Número Páginas:
68pp.
Autor(es): Ribeiro, A.
Keywords: Domínios das grandezas; Apoio metrológico; Laboratório central; Incertezas de medição
Info
Caracterização metrológica do padrão de referência de humidade do LCAM/LNEC (Gerador de humidade TSC 2500)
Este relatório apresenta a caracterização metrológica do gerador de humidade TSC 2500, que constitui o padrão de referência da grandeza humidade relativa utilizado no âmbito da actividade metrológica desenvolvida pelo LCAM/LNEC. Neste, são referidos os aspectos mais relevantes associados às grandezas mensuráveis, ao princípio de funcionamento, aos modelos matemáticos aplicados, e à sua calibração e programação.
Ano: 2007
Número Páginas:
48pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
|
Informações Científicas e Técnicas
Info
Método de confirmação metrológica de instrumentação científica - Uma abordagem probabilística
A Metrologia constitui um ramo da Ciência com uma aplicação transversal diversificada nos contextos científico, industrial e legal. Em todos eles, a actividade experimental assume um papel preponderante no processo de garantia da qualidade. Na actualidade, uma parte significativa da actividade experimental é desenvolvida no âmbito de Sistemas de Gestão (da Qualidade), os quais impõem requisitos normativos estritos visando a evidenciação objectiva da qualidade dos resultados de medição. Uma vez que a instrumentação desempenha o papel de meio que permite concretizar a medição, e considerando que a sua utilização tem uma finalidade contendo os seus próprios requisitos, a avaliação da qualidade deverá ser baseada numa comparação entre o desempenho metrológico da instrumentação e a exigência de exactidão inerentes a essa finalidade. Na vida útil de um instrumento de medição é observada uma permanente modificação da sua condição metrológica o que justifica a necessidade da sua calibração periódica e determina a necessidade de se promover um acompanhamento da sua evolução de modo a assegurar que essa condição é, em cada momento, adequada à sua aplicação. É neste contexto que se introduz o processo de confirmação metrológica, o qual consiste na aplicação de um método de verificação da conformidade da condição metrológica do instrumento de medição relativamente ao uso pretendido, após a realização de uma calibração. A forma de concretizar esta avaliação não constitui, ainda, um assunto consensual. A divergência mais significativa está relacionada com a definição do critério e dos parâmetros a aplicar, pelo que este documento pretende dar um contributo para a definição de um critério que seja, por um lado, consistente com a actual abordagem probabilística da medição e, por outro lado, adequado face às exigências de boa gestão financeira e patrimonial, em acordo com os objectivos preconizados pela abordagem subjacente aos Sistemas de Qualidade Total.
Ano: 2009
Número Páginas:
70pp.
Autor(es): Ribeiro, A.; Lages Martins, L.
Editor: LNEC
Keywords: Avaliação; Incerteza de medição; Garantia de qualidade; Calibração; Instrumento de medição
|
|
|