Artigos de Revista
Info
Kinetics comparison of alkali-reactivity tests for aggregates
![]()
Among the test-methods for evaluation of aggregates reactivity towards alkali-silica reaction (ASR), linear dilatation of mortar bars or concrete prisms is often used in several tests under various conditions, criteria and procedures of measuring and accelerating the reaction. As reactivity is an essentially kinetic property, the expansion limits in such tests, or even tests results for the same aggregate, should be kinetically inter-related. This paper presents a proposal of a kinetic relationship for critical reaction rates, evaluated from criteria of standard test-methods NF P 18-590, ASTM C 1260 and ASTM C 1293 . To do so, the critical expansion rate of these tests were corrected for a reference 1M alkalinity and depicted as Arrhenius plot. The high correlation of the regression line shows linearity of the plotted data, which was assumed as a criterion of kinetic compatibility between the said tests. The discussion includes a comparison with other tests and literature comments on their evaluation. The main interest of this study concernong the potential for ASR, is to discuss and compare methods aiming to improve the service life of concrete structures, by: i) selection of good materials; ii) decisions on the appropriate concrete formulation; iii) foreseeing possible problems allowing to plan monitoring and/or the need for adequate intervention as well as the possibility of test improvements. The extension of service life allows savings in raw materials and energy, improvement of the investment economics and, in the long term, lower investment requirements.
Ano: 2014
Número Páginas:
506-516 pp.
Autor(es): Gonzalez, L.; Santos Silva, A.; Jalali, S.
Revista: Key Engineering Materials
Editor: Trans Tech Publications
Volume:
Volume 634.
Keywords: Reactivity; Expansion tests; Alkali-silica reaction; Aggregates
Info
Laboratory test for evaluating limitation of flows during internal erosion in zoned dams
![]()
A new laboratory test, named the flow limitation erosion test (FLET), has been designed anddeveloped to study upstream flow limitation during the phase of progression of internalerosion in the embankment of zoned dams. Upstream flow limitation may occur because ofthe presence of the shell or a transition zone upstream of a cracked core. In the FLET, thesoil specimen is composed of core and upstream shell materials. These are compactedinside a test apparatus made up of several pieces assembled in steps. Then the soilspecimen is subjected to water flow through a predrilled hole in the core material tosimulate a concentrated leak, initiated, for example, by large differential settlement orhydraulic fracture. In most tests, the hole is also drilled in the upstream material to simulatethe scenario in which the mechanism causing the flaw in the core is also likely to affect theupstream zone. Combinations of the same core material and several types of coarse-grainedupstream materials (broadly graded and gap-graded soils) are tested for a range ofcompaction conditions and hydraulic loads. It is shown that FLET is capable of assessingwhether there is upstream flow limitation and whether the internal erosion process stops,shows a trend of slowing down, or progresses. Upstream flow limitation is shown to bedependent on the fines and gravel content, fines plasticity, and compaction water content ofthe upstream material. In the particular case of the tested gap-graded soils, it is shown to bealso dependent on the initial gradient along the upstream material.
Ano: 2014
Número Páginas:
463-476pp.
Autor(es): Santos, R. N. C.; Caldeira, L.; Maranha das Neves, E.
Revista: Geotechnical Testing Journal
Editor: ASTM
Volume:
37(3).
DOI:
10.1520/GTJ20130104
Keywords: Upstream zone; Flow limitation; Cracking; Internal erosion; Zoned dams; Test apparatus
Info
Laser ablation of iron-rich black films from exposed granite surfaces
Here, we investigated the potential of laser removal of iron-rich dark films from weathered granite substrates, which represents a very difficult conservation problem because of the polymineralic nature of the stone and of its complex deterioration mechanisms. As often occurs, biotite was the most critical component because of its high optical absorption, low melting temperature, and pronounced cleavage, which required a careful control of the photothermal and photomechanical effects to optimize the selective ablation of the mentioned unwanted dark film. Different pulse durations and wavelengths Nd:YAG lasers were tested and optimal irradiation conditions were determined through thorough analytical characterisations. Besides addressing a specific conservation problem, the present work provides information of general valence in laser uncovering of encrusted granite.
Ano: 2014
Número Páginas:
365370pp.
Autor(es): J.Delgado Rodrigues; Costa, D.; Mascalchi, M.; Iacopo Osticioli; Siano, S.
Revista: Appl. Phys. A. Materials Science & Processing
Editor: Springer Berlin Heidelberg
Volume:
117, issue 1.
Keywords: Cleaning; Iron-rich dark films; Nd:YAG lasers
Info
Linear and Sliding-Mode Control Design for Matrix Converter-Based Unified Power Flow Controllers
![]()
This paper presents the design and compares the performance of linear, decoupled and direct power controllers for three-phase matrix converters operating as Unified Power Flow Controllers (lIPFC). A simplified steady-state model of the matrix converter based UPFC (MC-UPFC) fitted with a modified Venturini high frequency PWI\I modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) power. ln order to minimize the resulting cross-coupling between P and Q power control, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. Direct power controllers (DPC) are then developed using sliding mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behavior but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross-coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and guarantee faster responses with no overshoot and no steady-state error. Ali the designed controllers were implemented using the sarne digital signal processing (DSP) hardware.
Ano: 2014
Número Páginas:
3357-3367pp.
Autor(es): Monteiro, J.; Silva, J. F.; Pinto, S. F.; Palma, J.
Revista: Revista IEEE Transactions on Power Electronics
Editor: IEEE
Volume:
Volume 29 / N.º 7.
Keywords: Unified power flow controllers (upfc); Matrix converter; Linear controllers; Direct power controllers (dpc)
Info
Long-term behavior of limemetakaolin pastes at ambient temperature and humid curing condition
![]()
This paper presents the reaction behavior of lime and metakaolin (MK) pastes submitted to long term aging at ambient temperature and relative humidity of 95 ± 5%. The results presented are the basis for an extensive research pointing towards the formulation of lime based mortars for conservation of historic buildings, namely in humid environments. MK, when mixed with calcium hydroxide, in the presence of water, originates a set of major hydrated compounds, specifically, stratlingite, monocarboaluminate and calcium aluminate hydrate. The type of hydrated compounds formed is dependent on the lime/MK ratio, being some of them unstable over time. This instability can compromise the mechanical properties of limeMK mortars. From this work different reaction kinetics with aging were perceived, being the best results in terms of the pozzolanic reaction obtained with 50% MK content. Pastes with less than 25% of MK also present reliable stability.
Ano: 2014
Número Páginas:
49-55 pp.
Autor(es): Santos Silva, A.; Gameiro, A.; Grilo, J.; Veiga, M. R.; Velosa, A.
Revista: Applied Clay Science
Editor: Elsevier
Volume:
88-89.
Keywords: Pozzolanic reactions; Hydration products; Tgdta; Xrd; Air limemetakaolin paste
Info
Madeira: um mundo de possiblilidades
![]()
Quando, no início de 2007, aceitei o desafio da Construção Magazine para uma colaboração regular na coluna
Ano: 2014
Número Páginas:
1.
Autor(es): Cruz, H.
Revista: Revista Construção Magazine
Editor: Grupo Publindústria,
Volume:
59.
Info
Mechanical and mineralogical properties of natural hydraulic lime-metakaolin mortars in different curing conditions
![]()
This paper investigates the mechanical and mineralogical characteristics of natural hydraulic lime NHL3.5 (NHL) mortars with different% of lime replacement by metakaolin (MK) under different laboratory and natural marine curing conditions. Tests were conducted at different curing ages, using compressive and flexural strength tests and thermogravimetric and X-ray diffraction techniques. NHL mortars cured at high humidity levels in natural and artificial environments present interesting results and some could be used in old masonries repair. The incorporation of MK improves the NHL mortars strength, being this increase mostly associated to the pozzolanic reaction.
Ano: 2014
Número Páginas:
pp 287294.
Autor(es): Grilo, J.; Santos Silva, A.; Faria Rodrigues, P.; Gameiro, A.; Veiga, M. R.; Velosa, A.
Revista: Construction and Building Materials
Editor: Elsevier
Volume:
51.
Keywords: Tgdta; Xrd; Characterization; Curing conditions; Metakaolin; Nhl3.5; Hydraulic mortars
Info
Medição não-intrusiva da densidade superficial de depósitos de sedimentos em camada fina
![]()
O processo de medição de espessuras e de densidades superficiais de sedimentos depositados em modelos físicos tem sido motivo de investigação, conhecendo-se alguns métodos para o efeito, mas todos eles exibindo limitações sérias, em especial quando se pretendem medir depósitos em camada fina, isto é, com poucos milímetros de espessura. O presente estudo refere-se a um método para realizar este tipo de medição, baseado na variação de resistência elétrica entre elétrodos que fiquem cobertos com a camada de sedimentos. Pretende-se aplicar um método de medição que não perturbe o processo de sedimentação, com sensibilidade para medição de camadas finas (até 1cm) de sedimento, que permita a medição ao longo do tempo, robusto aos efeitos eletroquímicos da água e robusto às perturbações do meio (variação de temperatura, salinidade e nível da água). Inicialmente é feito um resumo sucinto do estado de arte dos métodos de medição de sedimentos, com a descrição das vantagens e limitações de cada um e salientando a sua aplicabilidade à medição de sedimentos em camadas finas. Segue-se uma descrição do princípio de medição adoptado, identificam-se diversos fatores de influência que, na abordagem convencional, perturbam ou dificultam a medição pretendida, propondo-se soluções para os compensar ou os retirar da cadeia de transdução. É feita uma descrição do circuito eletrónico desenvolvido que permite implementar o método de medição proposto. Finalmente são apresentados os resultados de um estudo experimental feito em protótipo que mostram a viabilidade do método com as inovações introduzidas para superar as limitações do princípio de medição.
Ano: 2014
Número Páginas:
27-42pp.
Autor(es): Coelho, G.; Palma, J.; Alves, E.
Revista: Revista Medições e Ensaios
Editor: SPMet - Sociedade Portuguesa de Metrologia
Volume:
N.º 7.
Info
Metodologia para o traçado da Linha de Máxima Preia-Mar de Águas Vivas Equi - nociais em ambientes de transição: aplicação ao estuário do Tejo (Portugal)
![]()
Os trabalhos desenvolvidos por equipas de investigação sobre a zona costeira bem como as ferramentas de gestão e ordenamento dasregiões hidrográficas, como, por exemplo, os Planos de Gestão de Bacia Hidrográfica e os Planos de Ordenamento de Estuários, necessitamda definição de margem e de leito e, por conseguinte, do traçado da Linha de Máxima Preia-Mar de Águas Vivas Equinociais (LMPMAVE)que corresponde ao seu limite. Muito embora a definição destas áreas e respetivo limite esteja descrita na lei que estabelece a titularidadedos recursos hídricos, existe uma dificuldade prática em transpor para a realidade do terreno as conceções legais, particularmente emsistemas de transição, como os estuários. Assim, revela-se prioritário o desenvolvimento de uma metodologia abrangente e objetiva capazde responder a este desafio.No presente trabalho, apresenta-se uma abordagem metodológica interdisciplinar e integrada, baseada na recolha e análise deinformação bibliográfica, cartográfica e de campo sobre a área de estudo (estuário do Tejo), bem como a experiência adquirida notraçado deste limite noutros locais do país. Deste modo, foi possível desenvolver um conjunto de critérios para o traçado da LMPMAVEem ambientes de transição, que podem ser divididos em quatro tipologias: a)biofísica, estabelecida através da presença ou ausência devegetação halófita; b)tipo de estrutura/altimétrica, que se prende com as características intrínsecas da estrutura e sua elevação; c) de usodo solo; d) de índole legal, baseada na Lei 54/2005 de 15 de novembro.O desenvolvimento e aplicação desta metodologia ao estuário do Tejo permitiu dispor pela primeira vez do traçado deste limite nesteimportante sistema de transição e, simultaneamente, ultrapassar a dificuldade de implementar os conceitos legais de LMPMAVE noterreno, ao criar critérios objetivos de suporte à sua marcaçã
Ano: 2014
Número Páginas:
96-107pp.
Autor(es): Rilo, Ana; Freire, P.; Mendes, R.; Ceia , R.; Catalão, J.; Taborda, R.; Melo , Ricardo .; Caçador, M.; Freitas, M. C.; Fortunato, A. B.; Alves, E.
Revista: Revista da Gestão Costeira Integrada
Editor: Revista da Gestão Costeira Integrada
Keywords: Costeira; Metodologia integrada; Margem; Leito
Info
MODELAÇÃO DA INUNDAÇÃO FLUVIAL DO BAIXO MONDEGO
![]()
A região do Baixo Mondego tem sido sujeita a inundações cuja extensão importa caracterizar, em particular no contexto da aplicação da diretiva de avaliação e gestão dos riscos de inundações (2007/60/CE), com o objetivo reduzir o risco e as consequências prejudiciais que lhes estão associadas.O presente trabalho apresenta os resultados da modelação das inundações no Baixo Mondego, no trecho compreendido entre a confluência do rio Ceira e o limite de propagação da maré a jusante. Neste trecho, com cerca de 44.7 km de extensão, o sistema de defesa contra cheias inclui o controlo dos caudais de cheias nas albufeiras a montante, os diques de proteção nas margens direita e esquerda ao longo de cerca de 36 km e o sistema de inundação controlada dos campos.Neste artigo descreve-se a metodologia utilizada, justificam-se os cenários de simulação adotados, incluindo o funcionamento do sistema de inundação controlada do Baixo Mondego, analisam-se os resultados, dando-se ênfase aos níveis e velocidades atingidos e à propagação das inundações e apresentam-se os mapas de inundação.
Ano: 2014
Número Páginas:
41-54 pp.
Autor(es): Alves, E.; Mendes, L. S.
Revista: Revista de Recursos Hídricos
Volume:
Volume 35, Nº 2.
Keywords: Dique fusível; Sifões; Diques de proteção; Inundações; Rio mondego; Modelação numérica
|