Artigos de Revista
Info
Real-time forecasting urban drainage models: full or simplified networks?
Lead time between rainfall prediction results and flood prediction results obtained by hydraulic simulations is one of the crucial factors in the implementation of real-time flood forecasting systems. Therefore, hydraulic simulation times must be as short as possible, with sufficient spatial and temporal flood distribution modelling accuracy. One of the ways toreduce the time required to run hydraulic model simulations is increasing computationalspeed by simplifying the model networks. This simplification can be conducted by removing and changing some secondary elements using network simplification techniques. The emphasis of this paper is to assess how the level of urban drainage network simplification influences the computational time and overall simulation results' accuracy. The models used in this paper comprise a sewer network and an overland flow drainage system in both 1D/1Dand 1D/2D approaches. The 1D/1D model is used as the reference model to generate several models with different levels of simplifications. The results presented in this paper suggest that the 1D/2D models are not yet suitable to be used in real-time flood prediction applications due to long simulation time, while on the other hand, the simplified 1D/1D models show that considerable reductions in simulation time can be achieved without compromising simulation results (flow and water depth) accuracy.
Ano: 2010
Número Páginas:
2106-2114pp.
Autor(es): Leitão, J. P.; Simões, N. E.; Maksimovic, C.; Santos Ferreira, F.; Prodanovic, D.; Matos, J. S.; Sá Marques, A.
Revista: Water Science & Technology - WST
Editor: IWA
Volume:
Vol 62 No 9.
Keywords: 1d/1d and 1df/2d urban drainage models; Urban drainage; Network simplification; Flood forecasting
Info
Recycled Red-Clay Ceramic Construction and Demolition Waste for Mortars Production
Recycled aggregates may make an important contribution toward decreasing the adverse consequences of the production and the dumping of construction and demolition waste CDW on the environment. The results of the experimental research work carried outat Lisbon
Ano: 2010
Número Páginas:
236
Autor(es): Silva, J.; Brito, J.; Veiga, M. R.
Editor: ASCE
Volume:
Volume 22, Issue 3.
Keywords: Sustainable materials; Ceramic bricks; Mortars; Recycled aggregates
Info
Removal of microcystins by PAC/UF
The removal of microcystins (MC) by powdered activated carbon adsorption/ultrafiltration (PAC/UF) was investigated, focusing on PAC dose and addition mode, MC initial concentration (expressed as MC-LReq) and on the impact of background natural organic matter (NOM), assessed through model compounds (a mixture of tannic and humic acids) and Microcystis aeruginosa culture. Constant flow experiments were performed with a hydrophilic UF hollow-fibre membrane and a mesoporous fine-powdered activated carbon. In the absence of backgroundNOM,PAC/UF with 10 mg/L PAC and up to 20_g/L MC-LReq feed concentration achieved 9398% MC removal and a cycle-averaged permeate concentration below the drinking water guideline-value adopted by the World Health Organisation (WHO) for microcystin-LR variant. Single-pulse PAC dosing in the beginning of the UF-cycle allowed slightly lower MC concentration in the permeate compared to the multi-pulse PAC addition whereas no differences were found in terms of transmembrane pressure. Hydraulic retention time of 34 and 55 min resulted in similar permeate quality.NOM type and concentration and MC initial concentration determined the PAC dose to be used. While 10 mg/L PAC effectively controlled ca. 5_g/L MC-LReq in a model water with 2.5 mg/L NOM or with M. aeruginosa culture (cells and algogenic organic matter) 15 mg/L PAC were unable to achieve the WHO quality with a water containing higher concentrations of NOM (5 mg/L) and microcystins (ca. 20_g/L MC-LReq).
Ano: 2010
Número Páginas:
114-120.
Autor(es): Campinas, M.; Rosa, M. J.
Volume:
Volume 71/Revista 1.
Keywords: Nom; Microcystins; Pac/uf
Info
Removal of microcystins by PAC/UF
The removal of microcystins (MC) by powdered activated carbon adsorption/ultra
Ano: 2010
Número Páginas:
7 p.
Autor(es): Campinas, M.; Rosa, M. J.
Revista: Separation and Puri
Editor: Elsevier
Volume:
71.
Keywords: NOM; Microcystins; PAC/UF
Info
Segurança contra incêndio em habitações unifamiliares de madeira
O facto de a madeira ser um material combustível constitui uma das principais preocupações das pessoas quando se fala de segurança contra incêndio de construções de madeira. Contudo, os edifícios de madeira podem ser concebidos e dimensionados para terem desempenhos adequados em muitas situações, uma vez que a carga de incêndio depende essencialmente do recheio e não do material estrutural.Nos últimos anos, o crescente interesse pela construção em madeira, em particular de habitações unifamiliares, tem levantado algumas questões pertinentes, relativamente à segurança contra incêndio, que importa esclarecer.
Ano: 2010
Número Páginas:
2.
Autor(es): Palma, P.
Revista: Revista Construção Magazine
Editor: Grupo Publindústria
Volume:
nº 40.
Keywords: Habitação unifamiliar; Segurança contra incêndio; Madeira; Fogo
Info
Sensitivity analysis of a morphodynamic modelling system applied to a coastal lagoon inlet
This work investigates the recent morphological changes at the inlet of a complex coastal system (Ria de Aveiro lagoon, Portugal). This study was carried out usingbathymetric data analysis and numerical simulationsobtained with the 2DH morphodynamic modelling systemMORSYS2D. The present simulations considered only tidalforcing, and a sensitivity analysis was performed by tuningthe formula used to compute the sediment transports. Anon-uniform sediment grain size distribution for the Ria deAveiro inlet is considered in the numerical simulations,based on surveys performed in this area. The model resultsare analysed to assess if they resemble the observed trendsof erosion and deposition, as calculated from bathymetricdata. A quantitative analysis of the differences between thebathymetric changes obtained through surveys and thenumerical results over a period of 3 years consideringdifferent sediment transport formulations shows that theformulations of Ackers and White (1973) and Engelundand Hansen (1967) are the ones that best describe themorphodynamic changes driven by tides in the Ria deAveiro inlet.
Ano: 2010
Número Páginas:
275
Autor(es): Plecha, S.; Silva, P. A.; Vaz, N.; Bertin, X.; Oliveira, A.; Fortunato, A. B.; Dias, J. M.
Revista: Ocean Dynamics
Editor: Springer-Verlag
Volume:
60 (2).
Keywords: Morphodynamics . sensitivity analysis . tidal inlet .aveiro lagoon
Info
Sensitivity analysis of surface runoff generation in urban flood forecasting
Reliable flood forecasting requires hydraulic models capable to estimate pluvial flooding fast enough in order to enable successful operational responses. Increased computational speed can be achieved by using a 1D/1D model, since 2D models are too computationally demanding.Further changes can be made by simplifying 1D network models, removing and by changingsome secondary elements. The Urban Water Research Group (UWRG) of Imperial College London developed a tool that automatically analyses, quantifies and generates 1D overland flow network.The overland flow network features (ponds and flow pathways) generated by this methodology are dependent on the number of sewer network manholes and sewer inlets, as some of the overland flow pathways start at manholes (or sewer inlets) locations. Thus, if a simplified version of the sewer network has less manholes (or sewer inlets) than the original one, the overland flow network will be consequently different. This paper compares different overland flow networksgenerated with different levels of sewer network skeletonisation. Sensitivity analysis is carried out in one catchment area in Coimbra, Portugal, in order to evaluate overland flow network characteristics.
Ano: 2010
Número Páginas:
2595-2601pp.
Autor(es): Simões, N. E.; Leitão, J. P.; Maksimovic, C.; Sá Marques, A.; Pina, R.
Revista: Water Science & Technology - WST
Editor: IWA
Volume:
Vol 61 No 10.
Keywords: Simplification of sewer and overland networks; Flood forecasting; Dual drainage
Info
Sistema Tejo-Sado: recarga de águas subterrâneas
A recarga natural constitui os recursos hídricos subterrâneos naturais renováveis. Pode-se considerar, como fontes de recarga, a recarga por infiltração da água da chuva, a recarga a partir de cursos de água (cursosde água influentes), e no caso de aquíferos multicamada a recarga a partir da drenância de camadas adjacentes. A recarga por infiltração da água da chuva refere-se à quantidade de água que se infiltra abaixo do solo após os processos de evapotranspiração e de escoamento directo, e que vai ter um percurso subterrâneo, podendo,em condições de não exploração, ficar armazenada no aquífero ou constituir escoamento subterrâneo que posteriormente aflora à superfície, contribuindo para o escoamento dos cursos de água (escoamento de base). O sistema Tejo-Sado é constituído pelos seguintes três sistemas aquíferos definidos em Almeida et al. (2000): Aluviões do Tejo, Bacia do Tejo-Sado/Margem Esquerda e Bacia do Tejo-Sado/Margem Direita.Esta comunicação divide-se fundamentalmente em duas partes: (1) a caracterização da recarga para a primeira geração dos Planos de Bacias Hidrográficas do rio Tejo (aprovado pelo Decreto Regulamentarnº 18/2001, de 7 de Dezembro), com uma descrição sumária das metodologias utilizadas (Oliveira et al., 1999), e (2) uma perspectiva das metodologias utilizáveis para o cálculo da recarga do Plano de Gestão de Região Hidrográfica do rio Tejo e da segunda geração do Plano de Bacia Hidrográfica das ribeiras do Oeste, em conformidade com os objectivos destes planos e fazendo uso das metodologias sugeridas para o seu cálculo.
Ano: 2010
Número Páginas:
77-85.
Autor(es): Oliveira, M. M.
Revista: Tágides
Editor: ARH do Tejo, I.P.
Volume:
7.
Keywords: Ribeiras do oeste; Tejo; Plano de bacia hidrográfica; Balanço hídrico sequencial; Recarga; Águas subterrâneas
Info
Sistemas de águas residuais de muito pequena dimensão: aplicação da norma EN 12566
O tratamento das águas residuais domésticas pode ser feito através de sistemas localizados (onsite),não se verificando neste caso a utilização de redes públicas de colectores. Em Portugal é vulgar a utilização de fossas sépticas particulares como sistema de disposição das águas residuais domésticas no meio ambiente, em situações tão díspares que vão desde as habitações isoladas até às zonas periféricasde aglomerados urbanos, passando ainda pelo seu emprego generalizado em povoações dereduzida dimensão. Existe ainda um conjunto bastante diversificado de tecnologias disponíveis para o tratamento das águas residuais domésticas em unidades compactas prefabricadas que podem ser utilizadas em sistemas localizados.A norma EN 12566 estabelece os requisitos gerais relativos a instalações e equipamentos auxiliares utilizados no tratamento de águas residuais domésticas para uma população total equivalente (PTE)igual ou inferior a 50. Esta norma está organizada num conjunto de Normas Europeias e de Relatórios Técnicos que cobrem diferentes tipos de sistemas de tratamento e de disposição no ambiente de águas residuais domésticas.No artigo é feita uma apresentação da norma europeia EN 12566, sendo enfatizada a importância da normalização na uniformização do mercado europeu.
Ano: 2010
Número Páginas:
7p.
Autor(es): Ribeiro, R.; David, L. M.
Revista: Revista "Águas&Resíduos"
Editor: APESB
Volume:
Série III - n.º 13.
Keywords: Sistema de infiltração no solo; Instalação de tratamento; Fossa séptica; Normalização; Águas residuais domésticas
Info
Sobre a casa-pátio: elementos de enquadramento
N/A
Ano: 2010
Número Páginas:
7 p..
Autor(es): Baptista Coelho, A.
Editor: Grupo Habitar
Keywords: História do habitar; História da habitação; História da casa pátio; Habitação em pátio; Casa-pátio
|